Document 0qO95Ja1Z7axX63bKyQVLEDZM

kb>-uj-dlJL March 22, 1967 MONTHLY ACCIDENT SUMMARY February 1967 We had several serious accidents this month but no accident resulted in a disabling injury. Our total year to date remains as one, as compared to one for a similar period in 1966. Our frequency rate now stands at 0.71 versus 0.77 in 1966. One accident that occurred in the Cleveland office will be reviewed by the Doubtful Gase Committee on March 23. Approximately 2400 pounds of VC1 vented into poly charge area at the Niagara Falls plant. The poly had been cleaned and headed up by a chemical' helper who was being trained in this area. The helper failed to install 2 adjacent reactor manhead studs with nuts and when charge had been heated to 139F, the lead-asbestos gasket blew out causing the charge to vent. All personnel left the building for twenty minutes after activating the building emergency vent fans. This incident will be discussed at the weekly safety meetings. Production personnel will be provided with a thread die to chase the threads as necessary to be sure that the studs are not removed from the vessel pad. A pipefitter at Louisville plant was sprayed with VC1 and caustic while attempting to unplug a pipe line at the VC1 unloading station. Although pipe was open at both ends, there was pressure trapped by solidified caustic. Fortunately, a safety shower was close by and the pipefitter immediately washed off the VC1 and caustic. He received no serious burns. Calvert City was notified of this incident. Violation of lock-out procedure and poly safety check sheet by a poly cleaner and charge operator at the Avon Lake General Chemical Plant was one of the nearest potential fatalities we have encountered for some time. The poly safety check sheet had been filled out by the cleaner and charge operator but cleaner entered the poly without locking out the agitator. The charge operator started the agitator of the poly (38) by mistake, thinking he had started another poly (39). The operator rode on the Pfaudler blades (25 RPM). Fortunately, the area supervisor was close at hand and quickly responded to the poly cart alarm. The disconnect was disengaged and the agitator was stopped. The helper was taken to the hospital and treated for only minor bruises and cuts. Each shift foreman conducted a safety meeting with his people and reviewed the incident and emphasized the importance of following the safety procedures in the plant. DLD/mlr At tachment /Dennie L. Dowell NGC 15574 1M'.GOODRICH CHiiMXCAIj COMPANY 'OGS Month Year February 1967 Composite Reportable Injury Status Report Man 11 ours Month Year Disabling Iniurics Mo. Year Minor Inlurlos Mo. Year Frequency Rate Mo,, Year Severity Rate Mo, Year Da vs Lost Mo. Year Man Hours Since Last Disabling In iurv Days Since Last Dis abling In Titcv President'sCup Contest Ratine Lou i svilie Culvert City Avon Cun. Chem. Avon Dev. Center Akron Chemical Long Beach Niagara Falls ) flenry ' Cleveland 1071 1073 560 558 550 547 534 531 309 308 113 112 50 ' ' 275 50 275 ' 575 574 168,839 94,793 95,543 87,206 50,329 18,652. 7,314 47,064. 99,590- 366,935 203,627 197,728 176,222 106,378 36,477 15,504. 102,151 198,314 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 1 0 To cal BFG Chem. Plants Total Same Ko. Last Year 4037 4028 669,380 1,408,336. 0 1 3698 3677 623,096 1,294,679. 0 1 74 144, 0 21 39 0 48. 95 0 38 60 0 12 3.2 :0 14 20 0 5 .6 0 32 64 4r ' -i 2. 0 0 0 0 0 0 -0 6 0 9.79 ' 0 mz. 245 461 0 0.71 00 00 00 00 00 00 00 00 00 00 00 00 00 0 ' 29; 37 00 6 -3 00 00 819,645 380,280 ' 1,975,237 562,497 269,985 120,525 441,971 50,442 , 232,854 0 2.13 o 3 137 113 705 196 155 200 1712' 33 70 218 402 0. ' 0.77 0 0.70 0 1 1 2 3 4 5 6 7 8 Not ' Entered NGC 15575 DLD 3-17-67