Document 0qMOen1Dna38pR7y9r42DZ74d
y}R,6_ 3W*
000410
RUM-
TEFLON FINE POWDER/DISPEKSION OPERATORS C-8 BLOOD SAMPLE RESULTS
C-8 in Blood (ppm)
First Sample
Second Sample
Change
26.0
20.0
-6.0
24.0
25.0
+1.0
11.0
8.2 -2,8
9.4 7.9 -1.5
8.2 6.5 -1.7
7.0 7.7 +0.7
6.9 5.9 -1.0
5.6 4.2 -1.4
..,,4.4 4.3
; 3.9
4.9 +0.5 5.6 +1.3 3.6 -0,3
3.6 2.7 -0.9
3.5 2.1
4
2.9 2.8 -0.1
2.8 2,8 0.0
2.6 2.4 -0.2 2.5 1.8 -0.7
2.5 2.5 0.0
2.1 1.6 -0.5
1.6 1.5 -0.1
1.5 1.2 -0.3 1.3 1.1 -0.2
JWR:Idr/10/19/83
Bays Between Samples
363 364 391 364 363 364 337 334 365 401 364 362 363 357 365 391 336 349 288 384 366 362
% Per Year Change -23 +4 -24 -16 -21 +10 -16 -27 +13 +27 -8 -25 -40 -3 0 -7 -28 0 -30 -6 -20 -15
000411
TEFLON FEP OPERATORS C-8 BLOOD SAMPLE RESULTS
C-8 in Blood (ppm)
First Sample
Second Sample
Change
7.5 6.6 -.9
4.5 3.7 - A 3.1 2.8 -.3
2.1 1.5 -.6
1.8 1.1 -.7
1.8 1,6 -.2
1.6 1,4 -.2
1.25
1.20
-.05
1.20 0.95
1.00 0.79
-.2 -.16
0.86
0.75
-.11
0.75
0.72
-.03
'*i o
00
0.52
0.44
0.51
0.48
-.03
0.42
0.39
-.03
0.41
0.46
+.05
0.38
0.36
-.02
Days Between Samples
362 380 384 364 364 392 393 171 333 391 565 364 365 337 445 363 363
o p-i
a
% Per Year Change -12 -17 -9 -29 -39
-12 , -9
-18 -7 -8 -4
-15 -6 -6
+12 -5
JWR:Xdr/10/19/8.3
000412
SHORT SERVICE OPERATORS C-8 BLOOD SAMPLE RESULTS
Fitie Powder
Last Saoule
PPM .02 .19 .93 4.00
***
FEP
Days in Job
61 212
375
603
.05 95 .05 124 .15 135 .05 165 .23 492 .66 266
PPM Per Year Change +.09 +.24 +.03 - .18
+.15 +.10 +.38 +.09 +.24 -.24
JWRldr 10/19/83
000413
HEW HIRES - TEFLON
Date of First Sample
07/28/81
10/01/81
10/07/81
10/13/81
Date Hired
'C-8 Blood Level (ppm)
07/27/81
<0.007
08/03/81
0.009
04/20/81
0.007
04/20/81 :
0.015
Months on Plant Before First
-8 Blood Test
0
2
5 1/2
5 3/4
JWR:Idr 10/19/83
000414