Document 0qEnbv6RGy8gja3XYG210nL0V

A.I.A. FILE NO. 30-C(May 1958) PLAINTIFF'S EXHIBIT KE.WAN E& Am t. rican -$t an d ard KEWANEE BOILER DIVISION HOT WATER 28494 A.I.A. FILE NO. 30-C(May 1958) SQUARE-HEAT TYPE "R" BOIL A TRULY VERS AT I L BOILER FO Thousands of Kewanee's famous "Square-Heat" boilers have earned owner respect in every conceivable type of installation--in large homes, small factories and office buildings, schools, churches, stores and institutions. They are of a simple, effective design that results in trustworthy operation with little attention. They are easy to keep free of soot, scale and other impurities-- thus they are easy to keep efficient. These boilers are the practical, proven firebox type for installation with oil burner, gas burner, coal stoker or hand-fired coal grate. Even after installation, adaptation from one fuel to the other is relatively fast and inexpensive. The Kewanee Square-Heat will easily operate at 80% efficiency when fired at a rate to produce 150% of its SBI net rating. This means your Square-Heat will carry peak loads without wear or strain and with real fuel-saving economy. By building boilers better, Kewanee Boiler Division has become a leading manufacturer of fire tube boilers. This reputation means service, too--with a network of Kewanee representatives reaching into every state . . . putting a qualified Kewanee Man within 'phoning distance of every Kewanee owner. 12 sizes--producing 15 lb steam or 30 lb water at SBI net ratings from 216,000 to 1,200,000 Btuh steam; 243,000 to 1,350,000 Btuh water. 28497 SQUARE-HEAT TYPE "R" Kewanee, GAS- FI R E D PACKAGED UNIT Fora self-contained, completely automatic heating unit, Kewanee combines a Square-Heat Type "R" Boiler with a Kewanee atmospheric type drilled-port gas burner. The burner is factory assembled in the boiler base and covers the firebox floor. It can be ordered for natural, mixed, manufactured or L.P. gas. Firing rate is balanced with the capacity of the boiler. Operation is automatic, efficient, silent. Thermocouple control of main gas valve is furnished as standard equipment. Electronic controls for safety shut-off in event of pilot failure is optional. The entire combustion chamber may be inspected easily through a hinged cast iron access door, machine-ground to a close fit and lined with high temperature refractory. DIMENSIONS III'GAS-FIRED UNIT unit number 3R1 G 3R2 G 3R3 G 3R4-G 3R5-G 3RE G 3R7-G 3R8-G 3R3-G 3R13 G 3RI1-G 3R12 ' SBI net rating--MBtuh steam 216 264 312 360 432 528 624 720 840 960 : 1080 1200 --MBtuh water 243 297 351 405 486 594 702 810 945 1080 : 1215 1350 gross output .... MBtuh 324 396 468 ! 540 648 792 ; 936 1080 1260 1440 I 1620 1 1800 A--maximum width tt-in 2-714 2-714 2-7 >4 ' 2-714 3-0 3-0 3-0 3-0 3-7 3-7 ; 3-7 3-7 B--maximum length tt-in 2-914 3-314 3-914 1 4-314 3-914 4-514 ; 5-1 5-10 4-11 5-7 | 6-3 1 6-10 C--maximum height ft-in 5-6'4 5-614 5-614 5-614 6-2 6-2 6-2 6-2 6-1014 6-1014 : 6-1014 ' 6-101/, Dimensions include the optional insulating jacket. 28498 SQUARE-HEAT TYPE "R" .WAN EE OIL-FIRED PACKAGED UNIT Automatic operation on No. 1 or No. 2 fuel oil is provided by a Kewanee pressure atomizing oil burner matched to the design and capacity of its Square-Heat Type "R" teammate. Firing is smooth, safe, non-pulsating. Electronic controls are furnished as standard equipment on the 3R4-0 through 3R12-0 units and are available as optional equipment on the smaller sizes. Combination mounting plate and adjustable secondary air shutter holds burner firmly in place .. . provides access to combustion chamber. The floor of the combustion chamber is of pre-cast insulating-type refractory, installed at the factory. Boiler and skid base are welded into one rigid unit. No special base is required. i DIMENSIONS unit number 3R1-0 3R2-0 3R3-0 3R4-0 3R5-0 3R6-0 3R7-0,3R8-0 3R9-0 3R10-0 3R11-0 3R12-o SBI net rating--MBtuh steam 216 264 312 360 432 j 528 i 624 i 720 ~ 840 1 960 1080 1200 --MBtuh water 243 297 351 405 486 : 594 i 702 810 ! 945 ; 1080 1215 1350 gross output.......... VtBtuh 324 396 f 468 540 648 I 792 | 936 1080 ; 1260 1 1440 1620 1800 A--maximum width . ft-in 2-814 2-814 : 2-814 2-814 3-1 3-1 i 3-1 3-1 3-8 3-8 B--maximum length ft-in 2-914 3-314 3-914 4-314 3-914 ; 4-514 ! 5-1 ! 5-10 14-11 ; 5-7 . 3-8 j 6-3 3-8 6-10 C--maximum height ft-in 4-8 4-8 '4-8 4-8 5 3 ' 5 -3 : 5-3 5-3 ' 6-0 6-0 6-0' 6-0 Dimensions include the optional insulating jacket. 28499 |U vV American-Standard KEWANEE BOILER DIVISION lOI FRANKLIN STREET, KEWANEE. ILLINOIS 28500 Lit,'io :n U S A. -ML