Document 0qBBj9o4y1x5R7av8rMob30Xn
Healing Systems Pumps
Chicago Pump Company
2330 Wolfram Street
BRUnswick 4110
' Chicago 18
PRODUCTS--Return Line Vacuum Heating and Boiler Feed Pumps, Con densation, House, Booster, Fire Pumps, Circulating, Brine, Sewage, Bilge,
Sludge, Pneumatic and Tankless Water Supply Systems and Automatic Alternator for Duplex Sets of Pumps.
"CONDO-VAC"
Return Line Vacuum and Boiler Feed Pump for Heating Systems
"Sure-Return" Condensation Pump
for Low and Medium Pressure, and Systems up to 75,000 Sq Ft Radiation
Fig. 10--Duplex "Condo-Vacs" with Duplex Double Automatic Control
No vacuum on stuffing boxes, ample clear ance in rotating member. It costs less to operate a "Condo-Vac." "Condo-Vac" reduces corrosion in piping and boiler to minimum--because pump does not take in air from atmosphere and entirely elimi nates all air coming back from system. "Condo-Vac" is quiet, has a low inlet, entirely automatic, fool-proof, easy to maintain. Ask for bulletin 270.
Close-Coupled Pumps
Boiler Peed. Circulating, Tank Filling, Water Supply
Fig. 1SO--Close-Coupled, side suction pump. Capac ities range from S to 600 Gpm against heads up to 189 ft. Motors from 1/6 to 0 Hp. Discharge l'to 8 in. Closed and open type impellers. Bulletin 108.
Fig. 1946
"Sure Return" Condensation Pumps and Receivers are built for systems up to 75,000 sq ft of direct radiation and for low and medium pressures. Built in either single or duplex units. Duplex units are alternated in their operation by the Auto matic Alternator. Complete data in Bulle tin 250.
Vertical Condensation Pumps
for Low and Medium Pressure for Systems from 500 to 100,000 Sq Ft Radiation
The vertical condensation pump is designed to re^ ceive returns from lowest radiation. The receiver is placed underground--an ordinary hole sufficing if ' necessary -- and requires
tvery little floor space. Unit is shipped complete, easy to install, assembled so as to prevent steam leaks. Special bearings will stand up under hot water for several years. A special float mechanism is guaranteed not to leak or stick in stuffing box. Complete data and descrip tion in Bulletins 245, 58 and 255.
1204
Fig. 1940
Vertical Condensation
Pump
Heating Systems s<e.m
Rantes clones
129 Brookside Avenue
Boston, Mass.
New York Office: 101 Park Avenue
Barnes & Jones Vapor and Vacuum Systems of Steam Heating; Modulation Valves; Adjustable-Orifice Radiator Valves; Packless Quick-Opening Radiator Valves; Thermostatic Radiator Traps; Thermostatic Trap Replacement Units; Condensators (Boiler Return Traps); Float and Thermostatic Traps; Strainers; Damper Regulators; Gages; Systems of Zone Control for Steam Heating.
Complete Catalog on Request
Modulation Valves, Series K.--Packless Quick Opening Valves, Series F
Series K Valves have non-tarnishable indicating dial, non-rising stem, re newable disc seat. Tail piece extra heavy. Extra long to facilitate instal lation. Three mod els: lever handle, wheel handle, lock shield. Series F Valve furnished with wheel handle only.
Series K Valve
Size........................ Cap. Sq Ft Rad.*...
Vi'
30
>/.60
1* w too 180
Series F Valve
Thermostatic Radiator Traps
Sturdily made to precision standards. Sensitive in opera tion. Provide in stant discharge of air and water, pre vents passage of steam. Contains unique Cage Type
Thermostatic Unit, which carries its own thermostatic element, valve piece and valve seat, factory cali brated and locked in correct adjustment.
Trap Size
Capacity
and Number Sq Ft.@ l'/2#
Patterns
'h* x Vi" # 122
Vf 1 V." # 134 r * r #147
200
400 700
Ang.-R & LCornerSt'w'y-
Ang. 4c St'w'y.
Angle only.
Size...................................... Vi* W
w Wi 2*
Cap. Sq Ft Rad.*.............. 30 60 100 (80 270 400
Based on 2 oz pressure differential.
Adjustable Orifice Valves, Type H
May be adjusted for different capacities after installation. At all times provides in dication of the adjust ment. Operation is quiet. Unauthorized tampering with ad justment is virtually impossible.
Condensators
For returning water of condensation to boiler from open re turn line systems independently of boiler pressure, without change in operating condi tions, air binding, or admitting steam to the return side.
No................................ 31 32. 33 34 35 Cap. Sq Ft Rad.*. ... 700 1600 3500 6000 io.ooo
Thermostatic Radiator Cage Replacement Units
Offer complete and reliable trap re newal in practically every make of ther mostatic trap. You simply (1) remove the old cover and unit, (2) insert the new Barnes & Jones Cage Unit, (3) re place the cover, and the old trap will oper ate with its original efficiency.
Float and Thermostatic Traps
Handle large and sudden condensation loads. Large air and watercapacity. Large Boat assures instant opening of the dis charge valve. Cage Type Thermostatic Unit assures quick elimination of air.
Trap No.................... T4I : T42 T43 T44 T45
\vInlet 4c Outlet Tap- V w \x/i" 2"
Capacity Sq. Ft. @ 2#......................... 800 2000 4600 9600 20000
1205
IS