Document 0q9ob99M7er4BkqwOrRnL0dEd
f Monsanto
t. . . ti FROM (NAME A LOCATION)
DATE
SUSJECT
REFERENCE
TO
P. W. May, St. Louis Research Dept.
,January 15 1968
M. W. Farrar - Res 1
J. R. Darby - Res 2
DCHP - Brown Bridge
R. M. Parks - RPARK
i W. F. Waychoff - WW'AYC
WE 67-160
C. Paton - CPATO
E. C. Wilde - EWILD
Ken Wells - KWELL
J. A. Cannon - Res 3
.. W. M. Coaker - Res 3
"R. H. Mills - Res 3
N. W. Touchette - Res 3
}i
i i.
rv $^4 ij
The complaint from this company was a darkening of an adhesive made using our dicyclohexyl phthalate. Volatility and heat stability tests were run at several time and temperature combinations on several samples of DCHP in an attempt to answer this complaint. Two of the samples tested were from Monsanto:
1. Lot #710 returned by Brown Bridge
2. Current production DCHP
'
The third sample tested was Hatco's DCHP. "
Results:
$ Weight Loss
105C.
2 hrs
18 hrs
175C.
4 hrs
Color
1 .13 .84 1.2 Yellow clear 2 .18 .84 1.0 Lt. yellow cloudy
3. .11 .71 1.0 Lt. yellow clear
Since our product seemed to have slightly poorer heat stability than Hatco's, the DCHP samples were recrystallized from methanol and another volatility test run at 175C. for four hours. Although the weight loss was much higher here than with the DCHP as received, because the crystals were
%not quite dry at the start, the Hatco product was still
the lowest in weight loss and had the 1est color*
Results on recrystallized DCHP
175C. for 4 hours
$ Weight Loss
1 3.6 2 3.8 3 3.4
Color
Lt. Yellow Lt. Yellow White
DSW 586957
STLCOPCB4092291
2-
To: Ken Wells
January 15- 1968
This work only seems to substantiate Brown Bridge's contention that the material they returned had poor heat stability. In view of the fact that except for streaking during application which you say is a pro duction problem, this company now finds our current production DCHP acceptable, we will not test further.
Time: 16 hours
P. W. May ds
f
li
; DSW 586958
i - . .'
.
.
STLCOPCB4092292