Document 0q75zJdbVa8VbdaqgEgMo8Znk

IN REPLY REFER TO: H-- 5 UNIVERSITY OF CALIFORNIA LOS ALAMOS SCILrvnFIC LABORATORY (Contract W-7405-eno-36) P. O. Box 1663 Los Alamoi, New Mexico 87544 February 15, 1973 fro Mr. Robert P. Carter Industrial Hygiene Engineer Aluminum Company of America ALCOA Building Pittsburgh, Pennsylvania 15219 Dear Mr. Carter, The work presented at the Denver local AIHA meeting has not yet been published. I am enclosing a copy of a recent Progress Report since a portion of the activities described at the meeting are detailed in this report. We anticipate preparing a formal paper covering our work with asbestos for presentation at the May AIHA meeting. When a copy of this paper is available I will forward it to you. HJE: j s Enc. Progress Report (1) industrial Hygiene Group An Equal Opportunity Employer 4110841733 LA-5182-PR PROGRESS REPORT Aerosol Research and Development Related to Hea Ith H azard Analysis Quarterly Report July 1 through December 31, 1972 scientific laboratory of the University of California LOS ALAMOS. NEW MEXICO 87544 /\ UNITED STATES ATOMIC ENERGY COMMISSION CONTRACT W-7405-ENG. 36 411084 1734 This report presents the status of the Aerosol Research and De velopment program. The four most recent reports in this series, all unclassified, are: LA-4911-PR LA-4912-PR LA-4936-PR LA-5016-PR In the interest of prompt distribution, this progress report was not edited by the Technical Information staff. Printed in the United States of America Available from National Technical Information Service U S Department of Commerce 5285 Port Royal Road Springfield, Virginia 22151 Price Printed Copy S3.00, Microfiche SO 95 4110841735 of the University of Californio IOS AlAMOS. NEW MEXICO 87S44 /\ LA-5182-PFt Progress Report UC 41 ISSUED: February 1973 Aerosol Research and Development Related to Health Hazard Analysis Quarterly Report July 1 through December 31, 1972 Work performed by Aerosol Studies Section Industrial Hygiene Group Harry J. Ettinger, Project Manager Charles I. Fairchild Lawrence W. Ortiz Marvin I. Tillery This work supported by the National Institute for Occupational Safety and Health, Cincinnati, Ohio, Project R 072. 411084 1736 AEROSOL RESEARCH AND DEVELOPMENT RELATED TO HEALTH HAZARD ANALYSIS JULY 1 THROUGH DECEMBER 31, 1972 by Harry J. Ettinger, Project Manager Charles I. Fairchild, Lawrence W. Ortiz, and Marvin I. Tillery ABSTRACT Final development and documentation of the dispersion filtration technique for the preparation of asbestos standard filter samples has been com pleted and transferred to the NIOSH Testing and Certification Laboratory. Quality control monitor ing of these samples indicates the magnitude of variations in fiber count which may be expected. Work to generate fibrous glass aerosols for cali bration of the 10 mm cyclone was reactivated. Sam pling at 1.7 1pm, these cyclones exhibit a well de fined aerodynamic cut off for fibers greater than 2.2 pm (diameter). The Standard Instrument Calibration (SIC) sys tem developed to provide a coal dust aerosol for the testing of coal mine personal samplers was completed and shipped to the NIOSH Testing and Cer tification Laboratory. Coal grinding experiments have established a relationship between grinding conditions and product specific surface. Using these as a guide, air dispersed dusts appear to have predictable aerodynamic size characteristics. Initial studies with the LASL Spiral Centri fuge Aerosol Spectrometer indicate increases in aerodynamic diameter of as much as 30% for sub micron polystyrene latex (PSL) particles under high humidity conditions. Subsequent experiments using a horizontal elutriator indicate no effect when the temperature is kept constant throughout the experimental apparatus. Reevaluation of the Spiral experiments indicate that the change is the result of water condensation on the PSL caused by a decrease in temperature during sampling. SUMMARY Development of a liquid slurry filtra tion technique to provide standard asbestos filters for the NIOSH certification program was completed. Detailed instructions for preparation of these standards were prepared for NIOSH, and the person responsible for continuing this certification program was trained at Los Alamos. Future standards will be prepared at the NIOSH Laboratory in Morgantown, West Virginia. Over 400 filter standards were prepared for distribution by NIOSH to the various states participating in the certification programT Extensive qual ity control monitoring of these standards 411084 1737 1 was carried out at Los Alamos requiring con license. Theoretical calculations confirmed siderable asbestos fiber counting by several by experimental data show that 200 mCi of members of the section. These count data tritide provides adequate charge neutrali indicate variations up to + 50% under optimum zation. A detailed operation, calibration, conditions. NIOSH was advised of the appar and maintenance manual was prepared for the ent limitations inherent in this technique. PSIC and SIC systems. Work with the fibrous glass aerosol, To produce a bulk coal dust by micron- temporarily deferred at the request of NIOSH izer (fluid energy) grinding an empirical was reactivated. The fibrous aerosol system relationship has been established between was tested using a new glass fiber provided grinding pressure, grinding time, and prod by Owens Corning. While aerosol mass output uct specific surface as measured by air per varies with time, the system produces a uni meability. To minimize the time variable, form concentration throughout the aerosol a new powder feed system was employed to de test chamber, and should satisfy the re crease grinding time from approximately 4 quirements for cyclone calibration. The minutes to 24 + 5 seconds per 100 g of coal. fibrous aerosol ranges in diameter from 0.06 Additional data will be developed to deter to 3.4 urn, covering the range of "respirable" mine the reproducibility of grinding by this fibers as defined by Timbrell. A limited method. number of cyclone comparison experiments Aerodynamic sizing of dispersed coal indicate that the mass of fibers passing the cyclone is reproducible. Limited sizing data indicates a possible aerodynamic size cut off dusts was emphasized, with simultaneous use of the following aerodynamic sampling in struments: 1) Andersen Impactor, 2) An as no fiber larger than 2.2 pm has been ob served on the downstream side of a 10 mm nylon cyclone operating at 1.7 1pm. dersen mini-impactor, 3) LASL modified mini-impactor, and 4) Lovelace Aerosol Par ticle Separator (LAPS). Agreement of Construction, calibration, and perform aerodynamic size has been within + 15% of ance testing of the Standard Instrument Cal the mean of the 4 determinations; however, ibration (SIC) System was completed, and the og determined aerodynamically, varied from unit shipped to the Testing and Certification 2.1 to 3.5. Such aerodynamic sizing, as well Lab (TCL) in Morgantown, West Virginia. This unit, which is similar to the Prototype Standard Instrument Calibration System (PSIC) as electron microscopy indicated that the mass median aerodynamic diameter (MMAD) of dusts dispersed from coarse bulk powders (low sent to Cincinnati in July, will be used to check the performance of coal mine personal air sampling instruments. Several improve ments over the prototype unit were incorpo rated into SIC, with the two major changes being 1) replacement of the TSI Particle Mass Monitor with a GCA Respirable Dust Mon itor (RDM), and 2) replacement of the 4 Ci tritide aerosol charge neutralizer with a redesigned more efficient 200 mCi neutral izer. Installation of the RDM provides SIC with a fast response compact mass measure ment instrument designed specifically for use with coal dust. Reduction of tritium activity was necessary to satisfy the re specific surface) was little different from that of fine bulk powder; that is, as the specific surface decreased by a factor of 4 the MMAD increased by only 15%. In two ex periments, removal of a deagglomeration baf fle from the Wright Dust Feed (WDF) aerosol outlet produced an increased MMAD. The experimental program to evaluate changes in particle aerodynamic size under high humidity conditions was continued using the LASL Spiral Centrifuge Aerosol Spectrom eter and a specially designed horizontal elutriator. Initial data using the Spiral with three different polystyrene latex aero sols showed significant changes. quirements of TCL's radioactive materials I 2 411084 1738 Reevaluation of these data indicates that the test system produced a 5 C temper ature decrease in the humid air stream pass ing through the Spiral resulting in suffi cient Irater vapor condensation to account for the indicated increase in apparent aero dynamic size. The horizontal elutriator was constructed to permit its operation under constant temperature conditions, and the humidity generation system was modified to minimize any temperature increase in the ex perimental test system. Triplicate tests using 1 um polystyrene latex (PSL) show no increase in apparent aerodynamic size as previously indicated by tests using the Spiral. I. FIBERS A. Standard Asbestos Filter Samples Work during the first half of this sixmonth period was devoted to final develop ment and documentation of a standard proce dure for preparation of asbestos standard filter samples for the NIOSH Proficiency An alytical Testing (PAT) program. Final de velopment of the liquid slurry technique was completed to permit use of UICC chrysotile. This modification permits use of a basic material with reproducible characteristics, eliminates milling bulk asbestos, and sim plifies preparation of these standards. Particulate background material is aluminum oxide. Test procedures were standardized and detailed instructions for preparation of these standards were prepared for NIOSH, de tails of which are described in the Appendix to this report. Seven sets of standards were prepared during this period. Each set consisted of four different concentrations with approxi mately 15 filters per concentration (approx imately 420 filter standards). A continuing quality control monitoring procedure was de veloped, and eight filters from each set were reserved for counting at Los Alamos. Data from these samples counted by four trained people indicate variations up to + 50% (Table I). To provide additional qual ity control information for NIOSH, a com plete series of 10 "identical" standards were also counted. These data summarized in Table II, show variations of less than + 10% for any one counter, and +_ 20% for all counters. The NIOSH employee responsible for con tinuing this asbestos proficiency program visited Los Alamos for special training in preparation of these standards. Future standards are being prepared at the NIOSH Laboratory in Morgantown, West Virginia, with LASL providing fiber counting to assist in their development of a quality control program. Evaluation of the dispersion filtration technique indicates that the method is capa ble of producing fiber/particulate loaded membrane filters in a controllable and pre dictable fashion. This, however, can only be quantitated when fiber counts are as sessed by a single counter. Fiber count results obtained under conditions where several trained counters use the same op tics, and count the same wedges indicate variations as large as + 50% are possible, with typical variations on the order of + 30%. Typical fiber count results for a se ries of standard asbestos samples obtained by multiple counters appears in Table I. When additional variables are introduced (counters of varied experience, different sample wedges, different optics) unpublished count data contributed by other counting fa cilities participating in the NIOSH PAT pro gram indicate variations as large as sever al fold. The two most important single variables inherent in the technique of fiber counting appear to be the quality of optics availa ble (The number of fibers detectable can be direct function of the optical resolution of the microscope in use) and the attitude and experience of the counteF. A detailed list of the variables of concern would include the following: 411084 1739 3 Counter Ortiz Fairchild Gettemy Ettinger Average: o: Coef.Var.: TABLE I ASBESTOS COUNT DATA SERIES 149-152 ,, , -,'vl 149 13-A Asbestos Count Data Series 149-152 150 151 " ' .-1V' 15-A 13--B 15-B 13-C 15-C vi3-^;^"';. 15-d ;V 843 667 784 647 735 94 0.13 706 863 1000 470 863 804 1216 471 760 227 0.30 839 305 0.36 961 1255 1627 627 1294 1373 2725 902 1118 426 0.38 1574 795 6; 50 1255, 2176 " 1216 2157 " 2216 804' 3118 1431 2294 ' 1882 3039 "^3S3;!:: ^ -,V ' : ' 1373 - [ .. , ` 1'' 2221 ; _ iv sl'1` v .v',v.r;V . 598' : 692 711 0.44, v;. 0.31 -6'.33^./'. 1-; J TABLE II v ASBESTOS COUNT DATA - SERIES 12-E INDIVIDUAL FIBER COUNT DATA - TEN "IDENTICAL" -FILTERS Counter and Fibers 2 Counted/mm Filter Area* - - S ' : . ' ' SAMPLE CODE 12-1--E 12-2-E 12-3-E 12-4-E 12-5-E 12-6-E 12-7-E 12-8-E 12-9-E 12-10-E ORTIZ 1379 1414 1586 1310 1414 1310 1345 1345 1241 1310 FAIRCHILD 1655 1517 1621 1690 1655 1655 1966 1793 1945 1621 GETTEMY 1138 1172 ' 1207 1103 1103 1207' 1138 1276 1138 966 *0 ' * ETTINGER 1241 i/V- : 1069 i.276 ^ y'iiir .1172 :1207 f 1069 " '1138 `*'r ' ' 1103 {7 ' Average: o: Coef. Var. : 1365 94 0.07 1712 145 0.08 Average of four (4) LASL counters: Standard Deviation: Coef. Variation: 1344 265 0.20 1145 83 0.07 U15S /"Tn -V A ' 71 ' ' ! . \ _ 0.06 V`.y' f l. , ; 7" V,;." \r 4110841740 a) Quality of optics - As indicated previously, the number of fibers detected is a function of optical resolution. b) Microscope alignment - Proper illu mination and use of a green filter along with critical alignment of the objective phase plate and condenser annulus combine to improve image contrast. Optimum phase con trast correspondingly increases image reso lution and hence increases the number of de tectable fibers. c) Coverslip and microscope slide Microscope phase objectives are generally corrected for specific cover glass thickness and deviations will affect image contrast. Likewise, thick microscope slides (> 1.2 mm) scatter light, reduce optimum phase inter ference and also reduce image contrast. The net effect is, again, to reduce optical res olution. d) Quality of microscopic mount - The microscopic mount is an integral part of the optical system and hence can influence fiber counts. Good mounts should be optically clear, free of air bubbles and support the material to be counted in a narrow optical plane. e) Relative size of counting field The use of an eyepiece reticule prescribing 2 large counting fields (> 0.005 mm at 400 X) can influence fiber count results by con tributing to counter eye fatigue and encour aging a habit of scanning the microscopic viewing field (i.e. When counting over a large area a counter tends to superficially scan the counting field rather than proceed through a careful and meticulous examination of the field simply because he has more area to search). f) Particulate concentration - High particulate concentrations tend to mask small fibers and make counting difficult and tedious. Lower fiber counts can be expected under these conditions. g) Fiber concentration - High fiber concentrations make counting difficult and the natural tendency of a counter is to count only fibers that are easily distin guished. Under these conditions the small diameter fibers are frequently neglected. h) Attitude and experience of counter - As previously mentioned, this variable along with microscope quality is one of the most critical in the overall technique of fiber counting. Fiber count results are a direct function of the care and patience employed by each counter. Strict adherence to pre defined criteria, painstaking care, and a thorough examination of each counting field are prerequisites to obtaining meaningful data by the fiber count procedure. While there are many potential errors inherent in the proposed technique for moni toring airborne asbestos, the most impor tant aspect is that all these variables tend to reduce the number of fibers counted, and thus underestimate the potential exposure hazard. The need for development of alter nate techniques to monitor potential worker exposure is I apparent. Two potential objections have been raised concerning use of UICC material for the PAT standards. These objections are that the filters are unrealistic, and too difficult to count. Both complaints relate to the occurrence of fine diameter (< 1 urn) fibers in the UICC material. How ever these ifine fibers are probably also present in samples obtained when monitoring typical industrial exposures. In these in stances, the presence of easily counted rel atively large diameter fibers may obscure the presence of the finer fibers. At this stage, this speculation is not substanti ated but is a reasonable extrapolation based on the characteristics of chrysotile. An important aspect concerning small diam eter fibers is that the relative health hazard associated with these fibers is, at present, unknown. Since those fibers are "respirable", they may in fact constitute the greater hazard. -- Experiments with UICC Chrysotile "B" using the electron microscope have illus trated the presence of asbestos fibers with 411084 1741 5 diameters as small as 250-300 Angstroms. These diameters lie well below the lower limit of resolution of optical microscopes at magnifications of 400 to 500 X. Detec tion and measurement of these small diameter fibers was accomplished by transferring sam ples from membrane filters to electron mi croscope (EM) grids by fusing the collection filter surface with solvent vapor, then re plicating the altered filter surface with a carbon/chromium film. Small squares of the shadowed filter are cut and placed on EM grids and, the filter matrix gently dis solved away. The metallic replica is thus left directly adjacent and adhering to the EM grid. While some particle loss is to be expected during this transfer process, it is adequate to illustrate the presence of sub micron diameter fibers in UICC chrysotile. Typical electron micrographs are illustrated in Figs. 1 and 2. B. Respirable Sampling For Fibers During the latter part of this sixmonth period work has been directed toward the continuation of the fibrous glass aero sol studies temporarily abandoned in April, 1972. The original intentions of these studies were to include: Generation of a fibtous glass aerosol, aerodynamic classi fication of said fibrous aerosol, and cali bration of a 10 mm nylon cyclone for the sampling of fibrous aerosols to approximate the ACGIH definition of "respirable" dusts. Recent fibrous aerosol generation ex periments have been conducted with a new type of glass fiber supplied by the Owens Corning Fiberglas Corporation (0/C ID Code: E glass AA-12). This material is provided as a mat or batting in bulk form containing fibers ranging in diameter from 0.06 to 6.5 um. This size range is suitable for aerosol generation purposes as will be ex plained below. A schematic diagram of the fibrous aerosol generation system currently in use is illustrated in Fig. 3. A large quantity (- 60 gm) of this new glass was blendorized as a thin water slurry and thor oughly mixed to provide a consistent batch of fibrous glass dust for aerosol generation. The blendorization treatment served to chop fibers and thus reduce fiber length, with diameters remaining unaffected. The result ant aerosol contains fibers with a range of well defined diameters and multiple lengths. Preliminary generation experiments with this particular glass indicate that the aer osol output is extremely variable with time. Mass concentration variations sampling with open face filters have been observed to range from 28 to 81 ug/1 within a 1.5 hour sampling interval (Fig. 4). This apparent shortcoming is not a serious limitation as simultaneous samples taken over short in tervals (15 min) indicate that the aerosol mass distribution is relatively uniform throughout the sampling chamber. The average coefficient of variation for simultaneous samples at different sampling locations was + 11%. The previously noted variation in aerosol output as a function of time is in herent in the design of the generation sys tem. Packing of the fibrous feed plug is difficult to reproduce since a weighed quan tity of fibrous glass is compressed, while still wet, to a fixed dimension. Production of the fibrous aerosol is a somewhat arbi trary process, since fibrous bundles are shaved from the compact feed plug and aero sol production is dependent upon the random separation of individual fibers from these shaved bundles by the gentle, but turbulent agitation within the generator chamber. How ever, the fibrous aerosol produced is well suited for our purposes. Individual fibers with diameters as large as - 3.4 um (3.4 um physical diameter corresponds to - 10 um aerodynamic diameter) have been observed in the aerosol cloud. The range of fiber di ameters available for experimental work, under established generation conditions, ex tend from an aerodynamic size range of 0.2 to 10 um (microscopic diameters ranging from 0.06 to 3.4 um). This range of fiber diam eters (0.06 to 3.4 um) fits well into the class of "respirable" fibers as defined by Timbrell.* 6 4110841742 Recent work involving a limited number of experiments conducted with the 10 mm ny lon cyclone sampling at 1.7 1pm indicate that the collection characteristics of the 10 mm cyclone for short term sampling << 90 min) of fibrous glass dusts appear to be ex perimentally reproducible. Simultaneous sampling of the glass aerosol using two or three identical cyclones resulted in an av erage coefficient of variation of + 13% in the mass passing each cyclone. Tabular re sults for the cyclone sampling experiments appear in Table III. This observation is 2 contradictory to results obtained earlier using a different glass aerosol and long (> 4 hour) sampling times. All cyclone com parisons were made by taking simultaneous samples and monitoring the mass of fibrous aerosol passing the cyclones which was then related to the total challange aerosol as determined by open face filter samples. Limited fiber sizing data indicates that there may be an aerodynamic size cut off as no fibers larger than - 2.2 ym (diameter) have been measured (to date) passing the 10 mm nylon cyclone operating at 1.7 1pm. This diameter (2.2 ym) corresponds to an aerody namic diameter of - 7 ym. As an additional note of interest fibers as long as 518 ym (1.1 ym diameter) have been meas ured on the downstream side of the cyclones. The above observation (no fibers larger than 2.2 ym have passed the 10 mm nylon cy clone) indicates that the 10 mm nylon cyclone may prove a useful short term sampler for fibrous dusts. There are, however, certain reservations about the cyclone behavior re lative to fibers that need to be clarified and will be the major effort during the next quarter. II. STANDARD INSTRUMENT CALIBRATION (SIC) SYSTEM Construction, calibration and testing of the SIC system was completed in November and the unit (Figs. 5 - 9) was shipped to the NIOSH Testing and Certification Lab, Morgantown, West Virginia, in December. This unit is similar to the prototype (PSIC) sent to Cincinnati in August, but incorporates some improvements requested by NIOSH. One major change was replacement of the TSI Particle Mass Monitor (PMM) with a GCA Respirable Dust Monitor (RDM). This latter instrument provides rapid mass measurement and is designed specifically for use with coal dust. The RDM consists essentially of TABLE III CYCLONE COLLECTION COMPARISONS Run No. Fibrous Mass Passing Cyclone (mg) Total Challange Aerosol-Fibrous Mass (mg) Fibrous Mass Passing Cyclone (%w) Std. Dev. (Mass Pass.\ V Cyc. ) (o) Coefficient Of Variation (IB*100 1 2.010 1 2.235 2 0.935 2 1.205 3 0.367 3 0.470 3 0.470 5.192 5.192 3.754 3.754 1.163 1.163 1.163 38.7 43.0 24.9 32.1 31.6 40.4 40.4 3.1 5.1 5.1- 7.6 17.9 13.6 Average Coefficient of Variation: t ^ x 100 - + 13% 411084 1743 7 an impactor, 6 counter, associated power supply, sampling pump, and electronics. In operation the instrument impacts coal dust onto a vaseline coated mylar collection sur face, which is located between a B source and a counter. Attenuation of the 6 by the coal dust is measured and displayed as mass concentration. If a cyclone presampler is placed in the flow stream ahead of the ROM, the "respirable" dust passing the cyclone may be read directly. Upon receipt, calibration of the RDM agreed with a GCA supplied standard sample; however, mass readout of dust concentration in the SIC was considerably higher than ob tained by mass measurements using membrane filters (Fig. 10). RDM measurements were made to correspond to the mass indicated by these filters (Fig. 11) by adjusting the instrument calibration which appears to drift with time, or use; that is, recalibration to correspond to mass filter concentrations was necessary after approximately 100 RDM read ings. Individual readings from the instru ment varied considerably as shown by the Fig. 11 error bars, with an average coeffi cient of variation of 27.1%. It should be noted that the variations in mass concentra tion recorded by the RDM may be valid since the filters average out fluctuations in con centration over a 15 min period as compared to the 40 sec measurement time of the RDM. A second major change involved redesign of the tritide charge neutralizer to permit use of a 200 mCi tritide source in place of the 4 Ci source used in the PSIC system. This modification was incorporated to assure that the tritide neutralizer unit met re quirements of TCL's AEC license, which lim its permissible tritium activity to 250 mCi. To insure that 200 mCi activity was suffi cient to neutralize the charge on a coal dust aerosol,the activity required at ex pected concentrations and flows was deter mined theoretically and experimentally. In the absence of reference data concerning charge carried by coal aerosols,the charge was assumed to be /n / = 25 D where /n / is PP the average number of unit charges on a par ticle of diameter D expressed in microns. If the Wright Dust Feed mass output is con verted to number of particles generated per second by assuming the distribution has a count median diameter of 1 um, and of 1.8, the total charge can be estimated. When this is equated to the amount of triti um required to neutralize such a charge in the geometric configuration of the deionizer unit, it is found that 15 mCi provides suffi cient ion concentration. An experiment, uti lizing decreasing amounts of tritium con firmed that less than 150 mCi activity was sufficient to neutralize the charge on an actual coal dust aerosol. A compact case was designed and constructed to further im prove the tritide aerosol charge neutralizer. Additional, less significant improve ments of the newer unit included, 1) higher flow rate meters to accommodate personal sampler flow up to 2.5 1/min, 2) larger personal sampler ports in the aerosol cham ber, and special clamps to permit quick in sertion and positioning of personal samplers within the chamber, and 3) a modified ex haust system which eliminates the need for a pumping system to remove excess aerosol. The inclusion of a method to visually determine initiation of aerosol generation was con sidered, but visual observation of the coal dust aerosol by scattered light proved to be impractical in SIC due to light absorption by the coal dust. However, it was found that the RDM provided a reliable indication of aerosol generation within 2 min of start up. Performance of the SIC system was de termined in several dust dispersion runs. As a function of operating time, stability of coal dust concentration as measured by average coefficient of variation was + 10.1% at four different sampling positions within the chamber. Spatial uniformity of concen tration as measured by simultaneous membrane filter samples taken at two, -or three loca tions exhibited an average coefficient of variation of 7.2%. Both the stability and spatial uniformity were determined during 8 411084 1744 experiments in which the dust cloud was un disturbed. Additional experiments involving relocation of internal samplers, momentary opening of sampling ports, etc. caused tem porary increases of approximately 50% in the above variations. III. STANDARD COAL DUST AEROSOL Several comminution experiments utili zing the micronizer fluid energy grinder established that the product coal dust size is strongly dependent upon grinding air pressure, and to a lesser degree upon grind ing time. To achieve a uniform feed rate in recent experiments the sloping tray powder feeder was replaced with a vibrated stand pipe feeder. This decreased the time to grind 100 g of coal from 4+1 min to 24 + 5 sec, which resulted in a coarser coal dust (Fig. 12) as well as a 60% increase in the amount of coal recovered as product. Addi tional experiments are necessary to deter mine if the new feed method increases the reproducibility of grinding. The variation in measured specific sur face for bulk micronized coal is small, while the calculated specific surface based on size characteristics of the aerosolized dust varies considerably. Calculated spe cific surface is obtained by substitution of aerosol CMD and c^, determined from electron micrographs, into the Hatch and Choate e- quation for specific surface.3 Since o 9o can have an error of + 15%, the term 2.5 o . ._ 9 m this equation may produce a + 60% vari ation in calculated specified surface. This error combined with uncertainties in sam- ling the airborne dust makes precise corre lation of the calculated and measured spe cific surface difficult. Another factor which may account for a major part of the discrepancy between measured and calculated specific surface is the possibility that the size distribution of air dispersed dust is different from that of the bulk dust due to losses, shattering, agglomeration, etc. in the dispersion process. A review of aero dynamic sizing, microscopic sizing, and specific surface measurements indicates that while the bulk powder used for dispersion is made increasingly coarse, the airborne dust exhibits little change in size parameters. Thus, as the specific surface of bulk dust decreased by a factor of 4, the MMAD of the airborne dust increased by only 15%. In two recent experiments the deagglomeration baf fle was removed from the exit of the Wright Dust Feed and two dusts which had been pre viously dispersed with the baffle installed, were dispersed. The size parameters changed significantly (Table IV), but whether this change is due to increased agglomerates in the cloud or an actual increase in the num ber of large particles is not yet clear. Probably both mechanisms contribute to the greater MMAD when the baffle is removed from the WDF. The first two dusts listed in Ta ble IV (actually the same dust, but differ ent dispersion conditions) are within the range of size distribution desired for the "standard test dust", i.e. 3.75 + .25 ym MMAD and o > 2. 9- TABLE IV SIZE CHARACTERISTICS OF NIOSH COAL DUST DustSize Parameters Measured Calc.d CMDb g MMADC MMD um Mm ym M-l 7 M-17a M-41 M-4 la .40*.04 .53*.03 .54*.01 .611.07 2.091.18 1.991.16 1.911.01 2.001.08 3.511.4 3.61 .8 2.81 .3 4.81 .4 2.211.1 2.21 .6 1.91 .02 2.61 .7 aDispersion from WDF with deagglomeration plate removed. ^Average of at least 2 ESP-EM sizing sam ples. cAverage of MMAD obtained from 5 aerodynam ic size measuring instruments. dCalculated from. In MMD = In CMD + 3 ln3og. 411084 1745 9 Methods for determination of aerodynam ic size characteristics were improved during the period,. An Andersen impactor, two An dersen mini-impactors and the Lovelace Aer<<bsol Particle Separator (LAPS) were used during each run to obtain aerodynamic size distributions. The Andersen impactor provides the most reliable aerodynamic size distribution in formation. This instrument, operated at 1 cfm air flow, collects sufficient dust on the 75 mm diameter membrane filters used as impaction surfaces in a reasonable period of time to give good mass sensitivity. A plot of the size information indicates a log nor mal size distribution with little tail off at the extremes (Fig. 13). Greater reliance is placed upon these data than that obtained from other methods for estimating aerodynam ic size distribution. Tvro Andersen mini-impactors, one of which is a LASL modification of the commer cial instrument have also been used, primar ily to obtain a calibration of the mini in struments for coal dust by comparison with data from the large impactor. This sampler may be useful in field work, as well as to the TCL for routine monitoring of dust dur ing air sampling instrument tests in SIC. The MMAD obtained from the mini-impactors agrees fairly well with that obtained from the large Andersen, however, the mass sensi tivity is relatively poor because the mass of dust collected is only 0.1% of the mass of the plate upon which it is collected and weighed. Two-stage, 10 mm nylon personal sam plers have also been used to obtain esti mates of the MMAD of coal dust clouds. If 0^ is assumed to correspond to that deter mined by the Andersen impactor data, and total mass entering the cyclone is estimated from other data (membrane filters, total mass collected in aerodynamic samplers, etc), then the "respirable" fraction passing the cyclone can be found from gravimetric meas urement of total dust and dust on the per sonal sampler second stage filter. The MMAD of the dust can then be estimated from this information together with parametric curves of cyclone efficiency as a function of MMAD 4 and 0^ (Fig. 14). Knowing the respirable fraction (% passing the cyclone) and og, aerosol MMAD can be estimated. In general, MMAD's obtained by this method has been approximately 25% smaller than those ob tained by direct sampling techniques. Problems with the LAPS still exist since an accurate calibration of our instru ment for aerodynamic size greater than 2 |im, has not been obtained, inlet losses are sig nificant, and the laminar flow pattern near the exit filter is distorted. A calibration taken from Kotrappa and Light5 is being uti lized temporarily for aerodynamic sizes greater than 2 pm until PVT latex particles of 6 pm mean diameter are available to caliibrate the instrument. Inlet loss in LAPS has averaged about 10% of the total mass collected during a run, as determined from washings. This loss is acceptable so long as a reasonable determination of the mass can be made. For recent LAPS collection runs no final filter has been used in the channel; rather, a membrane filter is placed in the exhaust air line external to the head. Elimination of the filter in the channel appears to have improved the parti cle deposition pattern in this region. IV. EFFECT OF HUMIDITY ON AERODYNAMIC PRO PERTIES OF NONHYGROSCOPIC PARTICLES (This Activity Only Partially Supported by NIOSH) This study was initially carried out using the LASL Spiral Centrifuge Aerosol Spectrometer (Spiral).5 Aerosols generated from three suspensions of monodisperse polysytrene latex particles (0.3 pm, 0.987 pm and 1.95 pm) were aerosolized with a Retec compressed air nebulizer. The particles were dried by diluting the aerosol with dry air. Electrical charge was eliminated by passing the aerosol through-a parallel plate tritium deionizer. A small portion of this aerosol (-0.400 1/min) was drawn into the 10 411084 1746 deposition channel of the Spiral which oper ates by introducing the aerosol into the deposition channel in a thin layer separated from the deposition surface by a much thicker layer of clean air. The centrifugal force caused by rotation of the deposition channel directs the particles across the thick clean air layer to the deposition surface as they travel down the channel. All particles have essentially the same distance to travel across the clean air layer so each particle will be deposited a specific distance down the channel that is characteristic of its aerodynamic size. To study the effects of humidity on aerodynamic size the relative humidity of the clean air layer was varied by passing the elutriating air over warm wa ter . Temperature of the water was adjusted to provide the desired humidity. The re sults of these experiments are shown in Fig. 15 indicating an increase in particle aero dynamic diameter at high relative humidities. The increase is much greater for the 0.3 um particles than for the larger particles. During these experiments there was a change in both relative humidity and temper ature of the air between the entrance to the Spiral and the exhaust line. The relative humidity increased about 1.4%, while the temperature decreased from approximately 30 C to 25 C. These changes would cause the condensation of approximately 7xl0_` g of water per cubic centimeter of air which will condense on all available surfaces in cluding all particles large enough to pro vide a nucleation center. The growth of par ticles significantly larger than the mean free path of the condensing molecules is de scribed by the following equation,^ S-S,,=BnDct p (1) where So is the initial surface area of the particle, S is the surface area of the par ticle after time t, o is the density of the particle, D is the diffusion coefficient of the condensing molecule and c,, is the con centration of the condensing molecules far from the particle. In this instance (condensation of water on polystyrene latex) particle density remains essentially con stant. Condensation occurs rapidly when super saturation is reached so it seems rea sonable to assume that the temperature drop occurs as the air passes through the Spiral inlet thus providing equal growth times for all particle sizes. The measured change in size for large particles can then be used to predict the change in size for smaller par ticles assuming the change is the result of a condensation process. Based on the spiral data for the growth of 1.95 um diameter par ticles, theory predicts that 0.987 um parti cles would grow to 1.082 um diameter. The observed growth of these particles was to 1.065 um which is within 1.5% of the pre dicted size. Equation (1) must be modified for pre dicting the increase in surface of particles whose size approaches the length of the 8 mean free path of the condensing molecules. In this case the rate of change of surface is given by ds _ 8 t D c,, / 1 \ eft (zsr^r) \rvo r+A/ (2) where r is the radius of the particle; a is the fraction of molecules that strike the particle that condense (assumed to be unity) v = /k T ^ where k is the gas constant per \2nM 2I molecule, T the absolute temperature, and Mj the mass of the condensing molecule; A=X M1 + M. M_ the average distance trav- eled by a condensing molecule before it col lides with a gas molecule, where X is the mean free path of the air molecules and the mass of the "air" molecule. Equation (2) can be solved to relate the change in radius of these smaller particles with the change in surface of the large particles (previously defined by equation (1)) using the following relationship: 8n D (rl-ro)+ 8"A(ro-rl)+:9"(rl 'r va 3tt In A+rl 8nDc t A+r )+ (3) 11 411084 1747 where ro is the initial radius of the partide and r^ is the final radius of the par ticle. Equating the left side of equation (3) to the change in surface measured in the spiral for 1.95 and 0.987 |im diameter parti cles would indicate that 0.300 pm diameter particles will increase to 0.499 pm and 0.462 pm respectively. The observed change was to 0.4 pm. However, these smaller par ticles take longer to deposit, resulting in greater water evaporation from the particles as they travel down the Spiral deposition channel. Therefore, this discrepancy be tween observed and expected size for 0.3 pm PSL is consistent with the experimental con ditions. ~ To confirm these experimental data and theoretical predictions a new series of ex periments were completed using a horizontal elutriator to characterize;particle sedimen tation velocity. To eliminate temperature gradients most of the apparatus was enclosed in a water jacket. Hater was circulated through the jacket and also through a bub bler column where diluting air was humidi fied at the temperature of the water. Six experiments were conducted by nebulizing an aqueous solution of 1.011 pin PSL particles then diluting the aerosol with humid or dry air. After mixing,the aerosol entered a small chamber (.1.4 liters) located in a large water bath with the horizontal elutri ator. The horizontal elutriator sample was drawn from this chamber at a flow rate of approximately 300 cmVmin. The excess aer osol (-11 1/min) was withdrawn from the chamber through a double walled glass tube containing a wet and dry bulb thermometer. Circulating water from the water bath was passed through the outer annulus of this tube. The pressure in the small chamber was maintained at approximately atmospheric by balancing the intake and exhaust flow rates. Samples were collected on electron mi croscope grids placed at 5 cm intervals along the center line on the floor of the elutriator. The number of individual parti cles deposited on 16 grid openings was determined by scanning the openings "in -an electron microscope and counting, the indi- i - ,- "t-.- "(v i, ,v.'' `i-\ K" ' - -- - - vidual particles . ' Deposition 'concentration was then plotted as'a-function of-pehetra-: tion distance to.! characterize "the sedimenta- tion velocity of the particles. Figure 16 shows the average deposition-concentration as a function of penetration distance for allruns. The plottedconcentrations are normalized to the average deposition - conceit- . tration for the'first 90 centimeters. Pene tration distances-'- were' also adjusted accord-' ing.' to measured flow rates- through the' elu- " ' ->'-j -'v-" .. triator'so each, point represents the same, ,l. .-"V, deposition time. 1 Thesedataindicatethat the PSL particles behave.as;if they are 11% smaller in the more humid: constant temperar - ture environment, opposite- to the effect observed in the Spiral experiments which in cluded a 5 C temperature .drop; Several corrections werenecessaryto ' establish the:correct' volumetric flow through the horizontaly;e|utrlat6r'art_ich'.;Was-,neWsured: > by means of a bubble flow meter connected in . series with thd elutriatibr and the suction line. Air flow for the low humidity runs was adjustedassuroingvthe air in the flow , meter was immediately saturated at room tern- , perature and' that the soap added to the wa-, ter in .the, bubble flow meter would not affect vapor pressures ;! Indicated air flow for the humid runs was low since the- circulating water pump heated up the water slightly, caus- ing the experiment to be'conducted a couple of degrees centigradeabove room temperature. This drop in temperature, between the- water y bath containing the horizontal elutriator and the bubble flow meter caused water to be condensed in the line's ' By assuming that the ` air remained saturated but at' 'room" tempera- ture it was possible to;.-correct the i'ndicated flow rates. Temperature corrections were also made for all measurements. : :: These problems coupled with the very . 5 long sampling times (sl6 hours per sample); and the long sedimentation times. (-lOymin to... maximum penetration) make it impossible.-to , precisely determine the effects of high 1 y ., j* 12 4110641748 -V ' r 4 t ' v: t / } humidity on the aerodynamic properties of nonhygroscopic particles. The results of the horizontal elutriator experiments indicate that there is little or no effect of high relative humidities on the aerodynamic char acteristics of nonhygroscopic particles. However, experimental data obtained with the Spiral and the subsequent calculations indi cate that large errors can be made in the characterization of small particles in satu rated atmospheres if temperature drops of as small as one or two degrees centigrade occur prior to the dynamic characterization of aer odynamic size. Therefore, the sampling in strument should be at the same or a higher temperature then the air to be sampled, and no pressure drops leading to a reduction in temperature should occur before aerodynamic characteristics are measured. This potential problem will arise in instruments that have significant inlet pressure drops such as cascade impactors. The condition will also arise if the aerosol passes through a warm humid environment before reaching the sam pling instrument, i.e. characterization of exhaled aerosols with the instrument at room' temperature. An error in estimating lung deposition will also occur when sampling in a humid-high temperature environment (such as mining) where the ambient temperature is considerably greater than body temperature. V. WORK FOR NEXT QUARTER One major effort during the next quar ter will be directed toward aerodynamic classification of the aerosol produced with the new Owens Corning fibrous glass and cal ibration of the 10 mm nylon cyclone for the sampling of respirable glass fibers. Major emphasis will also be directed at completion of the "standard" coal dust test aerosol. In addition considerable time will be devoted to the design and construction of two "large" aerosol test systems to be sup plied to NIOSH and TCL by July, 1973. To terminate the humidity-aerodynamic size study, experiments are planned utilizing the Spiral to sample a submicron aerosol un der high relative humidity and constant tem perature conditions. This same apparatus will then be used to sample several types of fibers. REFERENCES 1. V. Timbrell, "The Inhalation of Fibrous Dusts," Ann. N.Y. Acad. Sci., 132, 255273 (1965). 2. Aerosol Research and Development Related to Health Hazard Analysis, Los Alamos Scientific Laboratory Project R-038 Quarterly Report, LA-4936-PR (Jan. 1 March 31, 1972). 3. T. Hatch and S. P. Choate, "Statistical Description of the Size Properties of Non-Uniform Particulate Substances," J. Franklin Inst., 207, 369-387 (March 1929). 4. O. R. Moss and H. J. Ettinger, "Respira ble Dust Characteristics of Polydisperse Aerosols," AIHA J. 31_, 546-547 (1970). 5. P. Kotrappa and M. E. Light, "Design and Performance of the Lovelace Aerosol Par ticle Separator," Rev. Sci. Instr., 43, 1106-1112 (1972). 6. O. R. Moss, H. J. Ettinger and J. R. Coulter, "Aerosol Density Measurements Using A Modified Spiral Centrifuge Aer osol Spectrometer, Env. Sc. Tech. 6, 614-617 (1972). 7. N. A. Fuchs, Evaporation and Droplet Growth in Gaseous Media, Pergamon Press, p. 3 (1959). 8. H. L. Green and W. R. Lane, "Particulate Clouds: Dusts, Smokes, and Mists," E & F. N. Spon Ltd. London, p. 92 (1964). 411064 1749 13 14 411084 1750 Fig. 2. Electron Micrographs UICC Chrysotile 'B', Millipore Filter Sample. Transferred to EM Grids. 4110841751 15 / Fig. 3. Fibrous Aerosol Generation System. 16 411084 1752 411084 1753 F ig . 4. F ib ro u s G la s s A e ro s o l: Mass C o n c e n tra tio n vs R e la tiv e S a m p lin g T im e . I17 /1 411084 1755 19 y W' 20 IOS AlAMOS SCItNTIflC IARORAIORV ' / MS' ' Wtt |v> 1 IOS AlAMO5. 0fCW MF.RICO h STANDARD INSTRUMENT CALIBRATOR I'ty* 7. SIC UppcT'Secrion, (front) 4110841756 411084 1757 2! l-'ig. 9. SIC Lower Section, (rear). 4110841758 Mass C o n c e n tra tio n U < g /l) Fi. IQe Mass concentration in SIC chamber, iisn^rsi^n run r-73. 411084 1759 23 \ l r 4110841760 "\ 24 >i I i Measured S p e c ific Surface X 10" ( cra^/cm^) 2.2 -- 1.8 -- 1.6 -- 1.4 -- 1.2 1.0 0.1 0.6 0.4 0.2 'grinding time: 24+5 sec. Fig. 12. 30 35 40 45 50 55 60 Grinding Air Pressure (psig) Specific surface of NIGSH coal dust as a function of micron lie- pressure. 4110841761 25 CUMULATIVE PER CENT l e s s than (WEIGHT) tW.Vii P-80 (NA-1.41 } ANDERSEN IHPACTOR SIZE DISTRIBUTION F-SO (NA-1.41 ) ANDERSEN IMPACTOR SIZE DISTRIBUTION 773 1SSS ------ 1*50 -- 3015 TOTAL WT -* MASS OATA (MiCPOGRAMS) 2*00 32fl5 2235 1*713 CUMULATIVE FRACTIONS ------ .0525 _ TOC 1 .1562 1 .3213 .5**6 .696! s ss* Tz # mo r 2.9x!n 0-p =2 .6 MAXIMUM PARTICLE DIAMETER (MICRONS) Fis- 13. Typical Andersen impactor aerodynamic size distribution results. 26 4110841762 Fig. 14. Respirable mass--ACGIH standard--as a function of aerodyrmaic mass median diameter for polydisperse aerosols. 411084 1763 27 28 4110841764 Singlet PSL depositions with (*) and without () humidity in the laminating air of the spiral (based on the dry calibration runs) x l0 "4cm o Ho b. 4110841765 O' H C O r-4 %4 H o c C*4 O U OOINO -H 4J Ou-H H 2p9 -mH oC xO u O U 4J au 41 D 4HH QS4H 1 APPENDIX PREPARATION OF STANDARD ASBESTOS FILTER SAMPLES September 1972 A. Materials and Apparatus 1. UICC Standard Reference Chrysotile 'B' - available on request from V. Timbrell, Pneumoconiosis Research Unit, Llandough Hospital, Penarth, Glamorgan CF6 1XW, Eng land. 2. Aluminum Oxide (A1203) - 0.3 ym mean diameter. Commercially available in bulk form from Buehler Ltd, Evanston, Illi nois. 3. Membrane Filters - Millipore AA, 25 mm diameter. (0.8 |im pore size) available from Millipore Corporation, Bedford, Mass. 4. Grade. 5* Toluene - Mallinkrodt Analytical Filter Holders w/Reservoirs - 25 mm, Gelman Instrument Co., Ann Arbor, Michigan, Cat. No. 1112. (A manifold arrangement with several filtration funnels attached makes multiple filtrations convenient. Fig. 1-2) . 6. Ultrasonic Bath - Sonicor (SC 150) Sonicor Instrument Corp., Farmingdale, New York, 1-1/2 Gal. capacity, 150 watt output. 7. Syringe Pipettes - large bore (0.8 cm I.D.) graduated, capable of delivering 10 cc with rinse attachment (Fabricated in our local glass blowing facility. Fig. 3). 8. Bottles - reagent type, 2 liter ca pacity with polyethylene lined stoppers. Corning Pyrex. B, Procedure Prepare four dispersions containing UICC chrysotile 'B', each having different fiber concentration levels (0.2, 0.4, 0.6 and 0.8 yg chrysotile/cc) and one dispersion containing A^O^ (3 to 8 yg/cc as desired) using analytical grade toluene as the dis persion medium. Weigh the desired quanti ties of UICC chrysotile 'B' (+ 0.01 mg) or AljO-j (+ 0.01 mg) into a 2 liter container and dilute to a measured volume with tol uene. Specific suspension fiber concentra tions should be maintained within limits 30 noted in this discussion. Thoroughly dis perse each separate suspension by sonication and intermittent vigorous hand shaking. Repeat as necessary until the dispersions are uniform. The relative uniformity of each dispersion is checked by visual obser vation of Tyndall light scatter within the suspension. A uniform dispersion will ap pear to have a great many small fibers, with very few large fibrous clumps. Fifteen to twenty minutes of sonication is normally adequate when accompanied by intermittent vigorous hand shaking of said dispersions. Dispersions at these concentrations can be stored several months prior to use in prep aration of filter standards. When properly dispersed, the resultant suspension concentrations are: Chrysotile 0.2 to 0.8 yg/cc (as prepared) A1203 3 to 8 yg/cc (as prepared) The filtration manifold is detailed schematically in Fig. 1. Photographs of the manifold, and large bore syringe pi pette are shown in Figs. 2 and 3. Shake chrysotile suspension to be fil tered, then pipette ten (10) cc into the filter reservoir and filter in a controlled fashion (- 0.4 - 0.6 cc/sec g 5"-7" HjO neg ative pressure - also see Fig. 1). Rinse the pipette with pure toluene into the fil tration reservoir before the reservoir goes dry. (A clean solvent rinse is included in order to wash fibers adhering to the inner pipette walls into the filtration reser voir) . Immediately, in sequence and before the filtration reservoir goes dry, pipette 10 cc of the AljOj dispersion into the fun nel. Allow - 3/4 of the AljOj suspension to filter through the Millipore filter and again follow with a clean toluene rinse. Allow filtration to proceed at a slow, con trolled rate (0.4 to 0.6 cc/sec) until the filter reservoir is void of liquid. Then 411084 1766 pull room air (at 20-30 1pm) through the "wet" Millipore filter, to facilitate dry ing. The air dried, asbestos -AljO^ loaded filter is then removed for counting and/or shipping. As a practical aid to these procedures, the following details must be observed in order to insure successful operation of this dispersion-filtration technique: 1. Asbestos should be UICC Standard Reference Chrysotile 'B'. 2. Prepare separate stock dispersions (suspensions) for each fiber concentration level desired. As a basis for calculations, assume ten (10) cc as the volume to be fil tered . 3. Dispersions must be dilute in order to prevent agglomeration. The chrysotile dispersions must not exceed 1.3 ug/cc tol uene. a123 dispersions (0.3 pm mean diam eter) must not exceed 11.0 ug/cc toluene. 4. Two separate dispersions (AljO^ and asbestos) for each series of "identical" filters must be prepared and these disper sions must be filtered in sequence; asbes tos first, followed by AljO^. One solution, containing both materials at the concentra tions needed causes extensive fiber/particu late agglomeration and a predictable fiber deposit concentration becomes impossible. 5. Optimum fiber/particulate distri bution on the membrane filter is obtained when filtration is limited to small disper sion volumes (20 cc maximum for each). 6. Dispersions must be subjected to sonication during preparation in order to break up loose fiber bundles and particu late agglomerates. 7. Dispersions must be agitated imme diately prior to the filtration process. Vigorous intermittent hand shaking through out a series filtration is adequate. 8. The vacuum filtration funnel (reser voir) must not be allowed to go dry between successive asbestos and AljO^ steps, or fibers already on th^ filter sur face will be washed f.om thei original site and be redeposited in a non-random fashion. Usually this "washing" phenomenon is ob served as a concentrated ring deposit on the membrane near the inner walls of the filtration funnel. Dispersions are not true solutions and must be treated as such. Dilute suspen sions, good initial dispersion, intermit tent vigorous hand shaking, controlled fil tration, sequential application of fibers then particulates, and operator consistency will produce a predictable and controllable fibrous/particulate deposit. Care and good judgment should be exer cised if parameters described in this meth od are changed. C. Typical Results The following table is intended only as a guide for the preparation of loaded Milli pore filters and was tabulated using actual samples prepared by the dispersion filtra tion technique. A moderate particulate 22 background (AljOj - 400 x 10 grains/mm ) was included on these filters using a dis persion concentration of 8 ug/cc.* 2 Dispersion Cone.(UICC Chrysotile 1 B1) (ug/cc) Volume Filtered Through 25mm Millipore Filter (cc) Actual Fibrous Mass Filtered per Millipore (ug) Fiber* Cone. Measured (Fibers/ 2 mm ) 0.2 0.4 0.6 0.8 10 10 10 10 2 724 4 966 6 1483 8 2172 "Average of 4 counters on same filter wedge. Phase contrast, 400X. These typical data, based on the aver age of four (4) fibrous deposit levels (data from 4 counters each counting the same wedge obtained from two different fil ters sampled from a consecutive series of "identical" filters) indicate the follow ing semi-quantitative relationship: For each microgram of UICC chrysotile 'B' fil tered through a 25 mm membrane (as described 2 above) one may expect - 250-350 fibers/mm . The higher value occurs at the lower fiber concentrations. 31 4110841767 J ! p 4 -fA*, 7-^, < ~ i ', ,* "\ ^: j1 ,,t \`. i jt ,'C, * i xc -^ ,r.I #K1 1 -'\ ' '., ' 'V'6v' ^/.y^sT ^ This relationship is reported as ap- proximate for several reasons: 1) Dis persions are not homogeneous solutions, 2) the particulate background influences the fiber count (i.e. higher particulate densities on the membrane surface tend to mask small fibers and hence lowers the fi ber count), and 3) variations are intro duced by microscopic tectwigues and optics used for counting fibers. Considering that the fibrous deposit is of primary interest, the particulate (AljOj) deposit may be adjusted as desired. Extremely high particulate deposits (on the order of 600 x 102 grains/mm2) should be avoided for the reason previously noted. ;'*r- '?', xV .:p. The dictated,; procedure,, when followed . in a careful and consistent manner,: is ca- pable .of producing predictable and control lable fibrous/'particulate. deposits oh a - "^7 r... membrane surface. ,t, . < ' , '' hr K ' .. . ' ..i/', 1ji!-. -l1 /' -*'*'*.' p. Safety Precautions </,, y,t s1 ,5 The inherent hazard associated with hu--' man exposure to microscopic asbestos fibers i' is well documented. - Extreme care should be exercised,, in the handling of liquid a*?*0" tos dispersions as well'-asji,tiheidry;' milled.- -Vf. material. Dispersion-preparation (sonica- '. K tion included), filtration and membrane packaging operations'[should: nil be .carried out in a well ventilated^chemical fume hood.., Toluene - a flammable and volatile organic solvent - should likewi.se ; be accorded, sim ilar treatment. _ t i. ;y V-1 pi--l %. r Fig. 32 A small capillary {connected in series between the vacuum source.andthe filtration manifold is used as a critical orifice to help control7 the filtration rate; A valve bypass allows one tOi conveniently, pull . * sufficient air through the wet membrane to aid. in drying. * ^ 4110841768 . 'C j^^ '--I'p-V; 4 Fig. 2. Filtration manifold. fig- 3. Large bore syringe pipette with rinse reservoir attachment. CM:33l(uO) 411084 1769 33