Document 0ooJzZE2N2vEEQa9qzbRmRqm
ASKARWS - Environmental Pollution
By: R.A. Lidgett & FI.A. Vodden
Introduction
The presence oT polychlorinated biphenyls* (PCBs) in wild-life specimens was first demonstrated 'in I960 by JeuscuM), who identified the unknown peaks,
interfering with GLC chromatograms in the analysis for organo-chlorine insect icides in bird-tissues, os chlorinated biphenyls. Since then a considerable amount of analytical evidence has been accumulated to support the view that PCD's exist in the environment over extensive regions of the earth in amounts which aro comparable in magnitude with those of insecticides.
Two features coimnon to both organo-chlorine insecticides and the PCBs being found in nature are that they are persistent and accumulate in oil and fat so that the highest levels are found in fatty tissues of birds ond in the blubber of certain marine animals. One noticeable difference is that, whereas insect icides are found in significant quantities in nearly all species of animal and plant life, significant amounts of PCBs are usually associated with the marine or aquatic environments. Thus the highest levels of PCBs have been found in fish-eating birds and in marine mammals, v*-/ w)
Net nil PCBs are found in wild-life; the chromatograms usually reported
suggest that homologucs containing
chlorine atoms are the most common, r-'
li is often claimed that the closest match for the chromatograms of wild-life
extracts is that obtained from commercial products corresponding to 50-5*i .
chlorine.
`
"'
Biphenyl is synonymous with diphenyl.
DSW 147977
STLCOPCB4039587
2* -
persistence rtnd Taxicily
TJic principal cause of concern, unionist conservationists and ecologists, about polychlorinated biphenyls and organo-clilorino insecticides is that they
are very stable chcmicul compounds. They are resistant to degradation by oxidation both chemically and biologically. Clearly, if the rate of dispersal of these materials into the environment is greater than the rate of degradation, there will be accumulation. ; The combination of persistence and accumulation in
fat during transition through a food chain can result in considerable increases in concentration of these compounds; it is quite possible that a very low level of perhaps, 1 part in 10" in water can be concentrated through a food-chain of marine or aquatic species, to levels of about 1 part in 103, which are sometimes
observed in the organs of fish-eating birds.
The toxicity of these compounds i6 relevant since the level which can be
accepted will obviously depend upon this. It is perhaps worth rnahing the point here that practically all chemical compounds"are toxic to some extent so that any persistent compound would eventually become a toxic hazard. Compounds of rolutive high toxicity, which arc degraded in the environment, do not necessarily pose ecological hazards. The acute toxicity of polychlorinated biphenyls to rats has been determined and, for example, the acute LD50 value for Aroelor I2'i2 is about h ml./leg. In the present context, however, the chronic effect of continued assimilation is probably more pertinent. The difference in sensitivity of diffore Bpecics makes generalisation impossible, but published information suggests that th chronic toxicity of PClls is one or two orders of magnitude less than that of DDT. For small mammals, feeding trials indicate that at levels of 1 - 10 ppm in foodstuf no significant toxic effect is observed, but at 100 ppm there are indications of some long term effects. Published work also suggests that, as with organo-chlorin insecticides, PClls affect the breeding success of birds.W Some marine animals, such as shrimp, arc sensitive to PCBs, but again, the toxicity of insecticides is known to be much higher.
Thus, although it may be argued that there is no immediate cause for alarm,
sufficient evidence exists to cause disquiet amongst ecologists and conservationist:
It is clear that continued accumulation of persistent compounds like PCBs and organ-
chlorine insecticides cannot be allowed, and means must be found to check the
increasing pollution of the environment.
,
One of the problems arising in any discussion of PClls in the environment stems
from the largo number of homolagues and isomers which arc possible. The commercial products, in fact, contain large numbers Of these in varying proportions. These different homologuos and isomers may have different properties. For example, Bincc the lower chlorinated compounds are rarely found in wild-life specimens, it if suggested that these arc degraded more rapidly than the more highly chlorinated species such os the pento- and hrxn-chlorinntcd biphenyls. The mixture of PCBs eventually found in n wild-life specimen may therefore be very different from that
initially fed into the ecosystem. Thus, although claims to have detected signifies quantities of Aroelor 12^2, or its equivalents, in wildlife are rare, it is not prudent to assume that these products arc completely acceptable. On the other hand polychlorinated biphenyls containing five and six chlorine atoms, such as arc prescr, in transformer oskarcls, have definitely been indicted as environmental pollutants.
DSW 147978
STLCOPCB4039588
ftnalysis
Because of the need to measure F.C.B.'s at extremely low levels (often 1 part in 10^ or less) the analytical method must be both specific and highly
sensitive. For this reason gas chromatography using electron capture detection
)>ub been universally chosen with occasional identification and structure
confirmation by gas chromatograph mass spectrometry,
Analytical methods vary in dotail between laboratories depending upon specific requirements, o,g, plant pollution control, analysis of vrildlifc samples etc. but essentially the method consists of tho following steps:-
1, Sample Preparation 2, Extraction of P.C.B.'s 3, Removal of interferences h. Concentration 5. Gas Chromatography & Measurement,
'
In general, it is found that wildlife samples being more complex require more extensive pretreatment than, for example, plant effluent and for this reason analysi of the latter will be described to illustrate'the basic analytical method.
The P.C.D.'b arc extracted from the aqueous sample by shaking with hexane and it is possible at this stage to introduce a concentration step by using a high ratio of sample to solvent, e.g, 500 ml, water to 100 ml, solvent. After two extractions the solvent is reduced to 2-5 ml. by evaporation on a steam bath and it is then passed through an alumina column with hexane as solvent to remove interfering non-, P,C,D, materials. The first 150 ml, of the hexane which elutes are collected from tho column and this is evaporated to u small known volume. This solution is used for gas chromatography,
Separation by gas chromatogrjdiy involves passing the sample in an
carrier
gas through a column packed with a material which will selectively retain components
of the sample for limited periods. Components elute.from tho column at periodic
intervals and ore detected using properties which differentiate ^tho/ components
from tho carrier gas,
DSW 147979
`
STLCOPCB4039589
-2-
.I
There ere many detectors in use in gas chromatography but for P.C.B, analysis it is only possible to use the electron capture detector. This is based upon the fact that certain compounds will abstract electrons from an artificially produced plasma (rndio^ active source), Reduction in electron concentration (in base current) is a-function of component concentration and car be measured with a suitable amplifier,
` Details of the gas chromatographic system used by Monsanto are available as an appendix to the paper plus illustrative chromatograms,
Measurement of the P.C.D, content from the gas chromatogram for plant effluent is generally a simple procedure - the chromatogram of the sample is compared with chromatograms of standard samples mude up from known P.C.D,rs and, for accurate analysis, calibration graphs can be prepared from specific peaks in the standard samples.
In the cose of environmental samples however, it is more difficult to obtain accurate measurement of P.C.D, content because in many of these samples dogrodation has occurred changing the chromatogram so that measurement by peak is less reliable. However, the experimental error although greater than that in the analysis of plant samples is still acceptable for the study of P.C.D, levels in the environment.
DSW 147980 STLCOPCB4039590
- 3 -.
pollution Control
It is clear that, if transformer and capacitor askarcls are to continue to
be used in the clcctricnl industry, positive effort must be made to control and
prevent pollution by these products.
'
Since the most significant levels of polychlorinated biphenyls arc found in
species associated with the marine or aquatic environment, the highest priority
should be given to preventing pollution of sewers and waterways. Atmospheric
pollution must also be avoided because PCDs, washed out by rainwater, may again
end up in r*ivers and sea.
The manufacturers of askarcls have a clear responsibility to prevent pollution at the manufacturing siteE Fortunately the process itself is "dry", so that aqueous effluent is not a by-product. Provided that sufficient care is taken to contain spillages and leakages during manufacturing and handling, pollution of drains and waterways can be avoided. Experience has shown, however, that it is necessary to study all aspects of the process, including drumming and tanker-loading facilities, with particular emphasis on the possibilities of leakages and spillages reading surfaco-water drains. Whore any chance exists of this happening, sumps or interceptor pits must be installed in the drainage system. It has also been found helpful to institute regular monitoring of plant effluent, using analytical tcchniqu similar to those described previously, to ensure that the instructions relating to the control of pollution are being observed. Atmospheric pollution at the manu facturing site is not a serious problcm,since the process is designed to avoid losse. but, again, good plant-keeping is essential to prevent accidental loss.
Close attention to detail and good plant-keeping or house-keeping practices
are the main hoys to pollution control and provention at capacitor and transformer t manufacturing plants. Facilities should be provided so that spills and leakages " cannot run or be washed away to surface or effluent drains. Sumps or interceptor , pits should be incorporated in any areas where askarcls can spill or leak. In
capacitor plants, vapour traps should be included at venting points to prevent atmospheric pollution. Care should be excereiso'd to ensure that all test-samples and waste askarcls arc collected for disposal in an acceptable way.
In the event of accidental spillage or leakage t)ii6 should be contained and
absorbed on dry sand, ash or sawdust ready for disposal by one of the methods
described in the next section.
DSW 147981 STLCOPCB4039591
Waste Disposal
It iB clear that askarel wastes should never be disposed of deliberately
down effluent drains or sewers and that the utmost care should be exercised to
prevent this happening accidentally.
'
In the capacitor industry, waste askarels may arise in scvc>..l ways. Liquid askarel from the impregnation cycle may bo too badly contaminated for further recycling; spent filter cake from the treatment plant will contain roughly its own weight of askarel; .finished capacitors or capacitor elements which have been
impregnated', but have failed electrically, test samples and cleaning solvents containing proportions of askurel are all waste products which will require disposal vIn the caso of liquid eskarcls, consideration should first be given to reclaiming. ` Some hsknrel manufacturers offer a reclaim service whilst others can refer users to specialist organisations who will do this. > Two basic methods of disposal of waste products exist. Those are dry tipping and incineration. In the case of aBlcarelB, incineration should only bo carried out under the correct conditions. . In order to break down the PCIi molecules thermally a minimum temperature of B00C is necessary. At this temperature a residence time of not less than 10 seconds will be required. At higher temperatures, shorter residence tiroes may be occcptahL Open-hearth incinerators ore not suitable for this operation and their use would serve only to volatilise the askarel and pollute the atmosphere. With suitnbly designed closed tube incinerators, howovor, incineration provides a good method for the destruction and disposal of uskarols. Since hydrogen chloride is one of the breakdown products, the effluent gases should he scrubbed with woter which can thon be discharged to a lime tank. Liquid askarel wastes can readily be handled by incineration, provided that heating is available on the feo^system to achieve pumping consistency. The major problem associated with such wiLiter probably concern! 1 storage, collection ond transport to the incinerator site.
For solid wastes the problem is rather more complex, and, at present, it is
thought that a two-stage process offers the most hopeful solution. The first
stage would consist of a rotary kiln furnace, operating at below 800C, to volntilis<
the askarel. This would then pass to the second stage for combustion at 1200C.
Such a system would be capable of dealing with capacitor elements, and even complete
capacitors if these were first broken open by a suitable crushing machine, in
addition to spent filter-cake and other solids. hv-the-'-cveniwy'-f Accidental
leakages or spillagej-of liquid
should be absorbed on dry sand, ash or sawdust .
and treated as solid waste.
Dry tipping, ond subsequent covering with earth at an approved site, offers o temporary expedient for dealing with askarel wastes. Although probably not acceptable us a permanent solution it is certainly better than indiscriminate dispersal of such products ini.o drains, waterways .and the atmosphere. Owing to its low solubility in wnler, askarels will be loaded out only very slowly from a
dry site, by rainwater, so contamination or streams and rivers from such sources will be slight. Tests carried out on stagnant water in close proximity to such a site indicated very low ( < h parts in l(r) levels of PCD. It is also known that soil normally contains multitudes of bacteria, some of which may be active against the lower liomologuos of PCDs, so that over very long periods of time significant degradation may occur. In these circumstances the delay imposed on the passage of the uskarcl materials into the aquatic environment may in fact provide a more porinnnont solution to the problem than Blight be expected. Nevertheless,
DSW 147982
STLCOPCB4039592
dry tipping should be regarded ns a temporary weuwure which should be abandoned when facilities for proper incineration Imvc been organised.
Remarks made about the capacitor industry also apply to transformer application! In the ease of transformers, a much bigger proportion of waste askarel could perhaps l>o reclaimed and efficient- use of reclaiming organisations should bo the first line of dofcncc against pollution. The establishment of acceptable specifications for reclaimed askarel could provide more incentive for reclaiming if, for example, these can be relaxed in any way. Certainly more efficient usage of reclaimed askarcls should form pari of the strategy for the continuing use of askurcls in transformers. As with the capacitor industry, groat care should be exercised to avoid Bpillagcs and leakages and where these occur they should be contained and absorbed on sond, ash or sawdust ready for subsequent disposal.
HAV/moh 27/7/70
DSW 147983 STLCOPCB4039593
HKIWIUltsT.KS
(1) Jenson, S, Now Scientist.. 32, 612, (1966). . (2) Prosit, I., Jeffries, D.J., & Moore, N.W., Environmental Pollution 1.3. {1970' (3) Holden, A.V, & Marsden, K., Nature. 216, 12?'j (196?). (k) Risebrough, H.W., Rieche. P., Pcaknll, D.D. Herman, S.G. & Eirven, 11,N.,
Nature. 220, 1098, (1968).
Monsanto Chemicals Lid., Ruabon, Wrexham, Denbighshire, U.K.
OSW 147984
STLCOPCB4039594