Document 0kjE7aQgwm1mjEqKp56QeMJO
ORGANIC CHEMICALS DIVISION
ESE
gtf$<SSSpecial Repor
18
MCS 153 Transfer Report
Transfer to Organic Development
January 7, 19^3
Job No. 4013 Written by: J. D. Sullivan
DEPOSITION EXHIBIT
Pifs 97
HARTOLDMON0041558
MONSANTO CHEMICAL COMPANY ORGANIC CHEMICALS DIVISION ST. LOUIS RESEARCH DEPARTMENT
96^Special Repo
18
&
MCS 153 Transfer Report
Transfer to Organic Development
Job No. 4013
January 7, 1963
Written by: J. D. Sullivan
o
TRAN 001301
'
HARTOLDMON0041559
DISTRIBUTION
1. Pile 2. K. L. McHugh 3. W. R. Richard, Jr. 4 . Dupliisate Pile 5. 6. J. D. Sullivan 7. R. E. Hatton - Development 8. L. R. Stark 9- L. E. Klein - Development 10. Extra 11. Extra 12. Extra
This report contains confidential information which is the
property of the Monsanto Chemical Company and which shall be
disclosed only to duly authorized persons. The recipient is
held accountable for the filing and safe custody of the report,
which must be returned on demand.
.
TRAN 001302
HARTOLDMON0041560
TNT'-?rX
' ?^e ` Nc.
A. INTRODUCTION ........................................................................................................ 1
3. CHEMISTRY................................................................................................................ 2
kmkmkm km kmkmkm rv>^
1. Degree of Polymerization . . .
2. Addition of Reactants
.
a. Stepwise Polymerization. .
b. Batchwise Polymerization .
C. PROPERTIESOP MCS 153...............................
1. Fluid Properties ........................... a. Viscosity ................................ b. Pour Point ................................ c. Viscosity Index Study. . .
2. Quality Tests ................................
m m no--4-'i --1 a \ o i o \ a i0 iC T icr> a *o iO \ u iu iv jiu i u iu iu i
3. Physical Properties....................... a. Densities ................................ b. Specific Heat............................
4. Electrical Properties.................. a. Dielectric Constants . . b. Power Factor ...........................
. c. Specific Resistivity . .
5- Flammability ................................ a. AIT.............................................
b. Flash Point................................ c. Fire Point ................................ d. High Pressure Soray Test . e. Hot Manifold Test..................
f. Molten Metal Ignition Test
6. Lubricity..............................................
a. Four-Ball Test ....................... b. Timken Wear Test .................. o. Shear Stability ..................
7. Performance-Tests....................... a. Oxidation-Corrosion Test b. Foam Tests ................................ o. Rust Testa ................................ d. Emulsion Tests .......................
5. Heat StabilityTests........................................................................... 9
9- Toxicity.................................................................................................. 9
10. Fatent Status. .................................................................................. 9
TRAN 001303
HARTOLDMON0041561
A. INTRODUCTION
This report is an attempt to bring together in one place all of the pertinent technology on the preparation and use of
MCS 153. The publication of this report will formally transfer the responsibility for this product from the Research Department to the Organic Development Department.
Although OS 81, Monsanto's synthetic steam turbine lubricant, has served as a suitable gas turbine fluid, the lower vis
cosity MCS 153 is desirable to facilitate start-ups at low temperatures. MCS 153 la a shear stable functional fluid having the following formulation:
Aroclor 1242 Aroclor 1232 Tricresyl phosphate (TCP)
Poly(Oxybutylene-MDI) Diol (PH-139) N-Phenyl-a-Naphthylamine (PAN)
DC-200 Silicone
75-3155 12.84#
10.00#
1.8055
0.0556 50 ppm
PH-139 is a shear stable viscosity index improver prepared by the reaction of polyoxybutylene diol (B-2000) with methylene di--phenylene isocyanate (MDI). This is a "long sought after" development in functional fluid research and its utility may be visualized beyond the current gas-turbine application. Shear stability is Imperative for hydraulic fluids of the Aroclor
and the Fydraul series and would prove extremely advantageous in the Skydrol fluids used in the aircraft industry.
An intensive effort was made to design a shear stable viscosity index improver which did not cause emulsification when the formulation was mixed with water. Non-emulsifying fluids are not a requirement for the gas-turbine application but it is an important property for fluids which could be contaminated by water by mechanical failures such as in steam turbine or ship board installations. Water washing, followed by dehydration, is becoming a popular method for recovering used hydraulic fluids and increasing emphasis is being placed on formulations which will not. emulsify in contact with water.
Of the viscosity index improvers prepared and tested, the most effective polymers, which also gave non-emulsifying fluids upon formulation, were ones prepared from polybutylene glycols (B-2000) and MDI. However, this polymer (FH-139) prepared in the plant from production size lots of B-2000 and MDI caused the resulting MCS 153 formulation to emulsify in contact with water. This emulsifying tendency was traced definitely to a contaminant, other than moisture and free acid, in the poly butylene glycol. Purifying this diol by customary techniques, prior to polymerization, failed to give non-emulsifying
formulations.
Iran 001304
HARTOLDMON0041562
1
2. Addition of Reactants
a. Stepwise Polymerization - In order to obtain the desirea polymerization, the diol and MDI were added in definite increments to supply the required excesses of each reactant, for various time intervals, during the reaction period. Specifically, two moles of MDI were added to one mole of the diol to form a polyoxyalkylene dllsocyanate. This diisocyanate was
reacted with two more moles of the diol to form a
poly(oxyalkylene urethane) diol. The cycle was repeated until a polymeric diol, having an approximate molecular weight of 10,000, was obtained.
b. Batchwlse Polymerization - If the total MDI and polyglycoi required were added at the same time in a single reaction mixture, the desired order of polymerization cannot be attained even with prolonged
heating. Under these conditions, the molecular weight of the polymer did not reach its maximum and optimum viscosity index improvement of the resulting formu lation was not obtained.
C. PROPERTIES OP MCS 155
.
1. Fluid Properties
Table I lists the pour point, along with the viscosities of MCS 153 at various temperatures. Similar results are listed for OS-81, Monsanto's current steam turbine lubri cant, for comparative purposes.
Table I
a. Viscosity (cs)
MCS 153
OS 31
at 20F at 40F
at 60F at 100P
at 130F at 175P at 210P
3,681.0 468.6 120.0 22.6
10.7 4.9
3^2
200,000 3,200
34 i 5-5 3.1
b. Pour Point
O'F +20P
In Table lc are listed viscosities of numerous formulations in which the shear stable viscosity index improver (PH-139) was added to various Monsanto base stock fluids.
TRAN 001306
HARTOLDMON0041563
3- Physical Properties
The following table lists the densities of MCS 153 at various temperatures along with the specific heat of this fluid at
77`F.
a. Density
Temperature
Gm/ml
20P 60F
100F 2108F
1.3663 1.3452
1.3247 1.2674
MCS 153
OS 81
b. Specific Heat at 77F, BTU/lb./F
0.30
0.31
Electrical Properties
Table II lists dielectric constants, power factors and specific resistivities for MCS 153 OS 31, DTE Oil 797 and Cellulube 220.
Table II
MCS 153 OS 81 DTE 797 Cell. 220
a. Dielectric Constant at 25C
at 60 cps at 1000 cps
6.52 5.94
5-95 2.22 5*84 2.24
6.91
b. Power Factor (%) at 25*C
at 60 cps at 1000 cps
52.0 . 17.6 0
3.45
1.08 0
17.5
c. Specific Resistivity (ohm-cm)________ '
at 25*0 at 100C
1.7x10* 5-OxlO* 1.4xl0n 2.0x10t 2.0x10 3-3x10 3-9x10 8.6x10
Dielectric constants and power factors were measured at 60 and 1000 cycles per second at room temperature (25C). Specific resistivity measurements were made at 25*0 and
100C with a megohm bridge.
TRAN 001308
HARTOLDMON0041564
c. Shear Stability
PH-139 In formulations of Aroclor and/or trioresyl phosphate are exceptionally shear stable. After twelve (12) passes through the Diesel Injector, the viscosity of the fluid is decreased by only 0.556.
7- Performance Tests
a. Oxlcation-Corroslon Test
For purposes of comparison, MCS 153 is compared to the 7808 type fluid specifications along with OS 81
and WS-3777. an Esso candidate for a 9236 type fluid. The following table lists the results of comparable oxidation and corrosion tests after a 72 hour
retention time at 347F per MII-L-7808C.
Viscosity
Initial Too Too
Viscosity Change
132
Acid
Metal Attack
Change Ms -JT-
Cu As
wt. Loss
i
os 81 34.5 3.15 17.9
1.9 0.14 .01 .03 .03 -.11 -.01 3.4
MCS 153 22.9 3.28 -4.9 -13-7 0.15 .02 .02 .02 -.34 -.10 8.1
WS-3777 52.3 10.4 >4.3 - 5-9 0.54 .02 .02 03 ' T 02 .01 2.3
7808C
11. 3.
-5_to
2.0 + .2 + .2 + .2 + .4 *.2 . -
No sludge or cocing was observed In the MCS 153 formu lation after th-- test was terminated.
The following t.ible lists the results of oxidationcorrosion teats on MCS 153 and OS 8l at 250#F for 168 hours.
OS 81
MCS 153
tal Attack, M 3/cm: M; Al
Pj Cu CD/Fe
0 -0.01
-=.0.01 . 40.05
-0.04
-0.01 -0.01
0 -0.04
-0.01
scosity: 100P Initial 100P Pinal 56 Change
210P Initial 210aF Pinal % Change
34.51 cs. 35-48 cs. +2.8
3.15 cs. 3.H cs. -1.3
22.55 cs 24.71 cs +9.6
3.24 3.31 +2.1
- TRAN 001310
HARTOLDMONOQ41565
8. Heat Stability
.
Laboratory tests showed that large molecular weight polymers (20,000 to 30,000) made from MDI and polyalkylene glycols degraded when heated for prolonged periods above 200F. On the other hand, lower mole cular weight (approximately 10,000) polymers are still
effective viscosity Index improvers and are more
thermally stable. In addition to shear stability and
non-emulslflcatlon, this thermal characteristic of the polymer was another reason for limiting the chain
length of the PH-139 going Into the MCS 153 formu lation. Table.Ill (see page 10) lists the changes in viscosity and acidity In MCS 153 and 03 81 after long retention times In a severe (static) oven test at 300F.
It will be noted that the acid build-ups and viscosity increases were only moderate at temperatures well in excess of the operating temperatures of a gas turbine.
9. Toxicity
The toxicity of MCS 153 Is unknown at present, but It la
anticipated that this fluid will prove to be relatively
non-toxic and non-lrrltatlng to the skin.
10. Patent Status
.
A disclosure (No. 2451) has been filed by the Organic
Division to cover the use of polymers, made from
polyglycols and diisocyanate, as shear stable, non
emulsifying viscosity Index Improvers for various
fluid base stocks.
2-25-63
J. D. Sullivan tRAh 0013
HARTOLDMON0041566