Document 0gpBna46MnJpQJBMeOz70V6EJ

i JULY 1953) CATALOG 98 28804 (JULY 1953) FOR HIGH AND LOW PRESSURE STEAM And Hot Water Heating The Kewanee M-800 Boiler is not only Scotch in name hut decidedly Scotch in its extra ruggedness and extreme thriftiness! t- It is designed, engineered and built to achieve new "highs" in fuel economy and operates at full efficiency even when pushed to produce 509/ more than its rated capacity. And back of this outstanding product is Kewanee's more than SO years expedience in the engineering and fabrica tion of steel boilers A "plus value" that can't be con verted into terms of dollars and cents. A "REAL" BOILER ENGINEERED TO DO A BIG JOB Kewanee puts more into a boiler, so the owner gets more out of it . . . that's the simple way to explain why Kewanee Boilers stay on the job for many extra years, delivering a lifetime of dependable service with notablesavings in fuel. There is more Engineering, more Material and more Experience built into every Kewanee Boiler and these are the elements which make them different and better. M-800 is a real Kewanee in every respect From the largest to the smallest size every M-800 is a big husky unit. surface which gives the water in the boiler a chance to pick up and use all the heat. The long travel of hot gases . . through the furnace, then back through the lire tubes . . holds them within the boiler until all usable heat is absorbed. More steam space and more steam disengaging area permit steam to rise without turbulence so only dry quality steam gets into the mains. The corrugated furnace (a feature of HM-800 for high pressure) adds strength and extra heating surface at the hottest parts of the fire andjnakes this boiler a fast steamer. There is more Furnace Volume providing plenty of space for complete combustion. It has ample heating Like all Kewanee Boilers, M-800 meets or exceeds the requirements of the A.S.M.E. and SB.I. Codes. Copyright 195}--KewanicRoss Corporation C^ EASY to clean and inspect Easy access to fire tubes is proytel . Through hinged doors on the fron r:,r smokebox, r*n wit 1" * nlate is removed in two parts / access to rear combustion chamber - Or rear chamber can be cleaned ' through lower access plate, w.thout removing entire back. accessible water surfaces Manhole on top of the bote ^d waff .*PA'TordyS" , rcuu.,00 a TM accessible water surfaces. Li* aL 1 TMeld' x-"ayed AND STRESS RELIEVED St#SS is an Ihfl dS Where Perfection at ss are stressed to^esnuctiom""5 ^ deKCted and *t specimens Pressure Botes" are^heat^dTa'tern Furnace' Kessanee H.gh allowed to cool gradually AH t?f"Pe/atlire of 1200" F,, thfn J2121Z1 28805 j 39 to } 1,313 MINIMUM WATER LINE k A riWGS, DIMENSIONS AA D DAI A (t set - in; hes) Boiler Number -- High Pressure -- Low Pressure Hm-878 LM-878 HM-879 'hm-880 LM-879 LM-880 Hm-881 LM-881 Hm-882 LM-882 SBI Rating--Horsepower -- Steam Radiation -- Water Radiation -- Btu per Hour -- Steam per Hour--212F sq ft sq ft 1000's Ib 39 5470 8750 1313 1 350 44 6080 9720 1459 1500 52 7290 1 1660 1750 1800 61 8500 1 3600 2040 2100 74 1 0330 1 6520 2479 2560 SBI Net Rating -- Steam -- Water -- Btu per Hour Certified Output Rating Firing Rate -- Oil gph* ' * -- Gas Btu hr . sq ft sq ft 1 000's hp ! 1 000 s 4500 7200 1 080 59 16 2460 5000 8000 1 200 66 18 2740 6000 9600 1440 ' 78 22 3280 7000 1 1 200 1 680 r 92 26 3830 8500 1 3600 2040 111 31 4650 Heoting Surface (SBI min) Furnace Volume (SBI min) Net Furnace Volume sq ft cu ft cu ft 322 39.1 45.8 358 43.5 48.4 429 52.1 57.9 500 60.8 62.4 608 73.8 79.8 Safety Valve Capacity -- over 15 ib swp -- 1 5 Ib swd A -- Boiler Diameter B--Boiler Length lb steam per hr .lb steam per hr 2576 1610 4-6 1 1-8 2864 1790 4-6 12-7 3432 2145 5-6 1 1-7 4000 2500 5-0 1 2-9'/: 4864 3040 5-6 1 3-2 C -- Steam Supply Height D--Smoke Outlet Height E-- Water Column Height 6-6 6-6 7-0 7-0 7-6 '/, 6-4 6-4 6-10 6-10 7-4 5-1 5-1 5-6 5-6 5-9 A F --Furnace 0. Dio. at Front G -- Furnace Height 2-3'/, 3-0 2-3 A 3-0 2-6'/, 3-1 A 2-6 '/) 3-1 '/, 2-9 A 3-3 H--Steam Supply J--Safety Valve K -- Feed Water, each side L -- Return 1 5 Ib swp, each side M -- Blow-off 3-0 3-6 3-1 3-7 3-8 3-6 4-3 4-3 4-4 4-5 6-7 7-1 6-6 7-1 7-4 4-4 4-4 4-4 4-4 4-9 4-0 4-0 4-0 4-0 4-3 N -- Smoke Outlet--Width O--- --Length 0-1 ! 0-1 1 1 -0 1-0 1-1 2-5 2-5 3-0 3-0 3-4 P -- Support -- Length R-- --Width S-- --Height T-- --Location U-- --Center to Center 3-1 1 A 1-4 1 -6 2-3 6-1 1 3-11 A 1-4 1 -6 2-3 7-10 4-5 A 1-5 1 -6 2-4 6-9 4-5 '/, 1-5 1-6 2-4 7-1 1 5-1 A 1-6 1 -6 2-5 8-1 V -- Tube Replacement Space 7-2 8-1 6-1 1 8-1 A 8-2 Steam Supply Size--15 Ib swp4 -- over 1 5 Ib swp * * Blow-off Size Return Size 1 5 Ib swp, each side Feed Water Size Outside Surface to Cover sq ft 0-6 0-4 0-1 'h 0-4 0-1 '/ 1 65 0-6 0-4 0-1 A 0-4 0-1 '/* 1 80 ; 0-8 0-4 0-2 0-4 0-1 % 1 80 0-8 0-4 0-2 0-4 0-1 /< 200 0-8 0-6 0-2 0-4 0-1 Zi 230 Breeching Diameter -- One Boiler Stack -- Diameter -- Height Breeching Diameter--Two Boilers Stack -- Diameter -- Height Approx. Weight-- 15 Ib swp --125 Ib swp --150 Ib swp 1-9 , 1-10 Mi ; 2-0 j 1-7 1-8 ' 1 -9 ! 1-10 ! 2-2 2-0 40-0 40-C 3 5-0 4C-0 2-3 | 2-1 ' 2-4 2-2 2-6 | 2-4 ! 2-7 1 2-10 2-5 ; 2-8 45-0 - 45-0 40-0 ' 45-0 | 45-0 Ib 7000 : 7400 Ib 7600 ' 8000 Ib 8200 8700 8200 10000 10400 8800 11100 11500 1 1 300 1 I310C 1 13900 I POWER FOR HfSU PRESSURE )0,000 BTU FOR ZOWPRESSURE 1---------- r------- b------------------------------------- i HM-883 LM-883 87 1 2150 1 9440 2916 3010 10000 1 6000 2400 131 37 5460 715 86.8 87.5 HM-884 LM-884 1 09 15180 24280 3643 3750 1 2500 20000 3000 164 46 6840 893 108.5 1 10.2 HM-885 LM-885 I 30 1 8220 29150 4373 4510 15000 24000 3600 195 54 8200 1072 130.2 141.1 HM-886" ' HM-887 LM-886 LM-887 152 21 250 34000 5100 5260 174 24290 38860 5830 6010 17500 28000 4200 20000 32000 4800 228 64 9560 261 73 10920 1250 151.8 153.7 1429 173.5 174.0 Hm-888 IM-888 217 30360 48570 7286 7510 25000 40000 6000 326 91 13670 1786 216.9 217.0 HM-889 LM-889 ' 26V 36430 58280 8743 9010 30000 48000 7200 392 1 10 1 6400 2143 260.3 262.9 HM-890 LM-890 304' 42500 68000 10200 10510 35000 56000 8400 456 127 19120 2500 303.6 308.8 5720 3575 7144 4465 8576 5360 10000 6250 11432 7145 14288 8930 17144 10715 20000 12500 5-6 14-10 6-0 16-1 6-6 16-7 6-6 18-7 7-0 17-9 7-6 18-1 1 8-0 20-0 8-6 20-1 7-6 Vi 7-4 5-9 Vi 8-0/2 7-10 6-1 V2 8-6 V, 8-4 6-5/2 8-6/2 8-4 6-5 Vi 9-0 Vi 8-10 6-9 Vi 9-7 Vi 9-4 7-3 10-4 Vi 10-1 7-10 Vi 10-10/i 10-7 8-4 2-9 Vi 3-3 2-11 Vi 3-5 3-2/2 3-6/2 3-2/2 3-6 Vi 3-6 3-8 3-8 Vi 3-9/2 4-1 4-2 Vi 4-5 4-4/ 4-2 4-9 4-10 5-4 5-5 5-5 5-6 5-7 5-0 5-0 5-0 6-6 5-6 6-6 7-0 7-0 8-2 8-10 9-3 10-3 9-10 10-6 11-0 n-o 4-9 5-3 5-8 6-2 6-3 6-5 6-7 6-7 4-3 4-5 5-4 5-4 5-6 5-6 5-6 5-6 1-1 1-2 1-3 1-3 1-4 1-4 1-5 1-6 3-4 3-6 3-11 3-1 1 4-7 5-4 5-7 6-1 5-1 Z, 1-6 1-6 2-8 9-6 5-7 Zi 1-7 1-6 2-9 10-6 6-1 1-8 1-6 2-10 10-6 6-1 1-8 1-6 3-4 12-0 6-6 7i 1-10 1-6 3-5 n-o 7-0 Vi 1-10 1-6 3-5 12-0 7-6 2-0 1-9 3-6 13-0 7-6 2-0 1-9 3-7 13-0 9-10 0-8 0-6 0-2 0-4 0-1 Vi 260 2-4 2-2 45-0 10-9 0-8 0-6 0-2 0-4 0-1 Vi 305 2-6 2-4 50-0 10-8 0-8 0-6 0-2 0-4 0-1 Vi 340 2-7 2-5 50-0 1 2-8 0-8 0-6 0-2 Vi 0-4 0-1 'h 380 2-9 2-7 55-0 M-7 0-8 0-6 0-2 Vi 0-4 0-1 Vi 390 2-11 2-9 50-0 12-7 6-10 0-8 0-2 Vi *0-6 0-1 Vi 440 3-3 3-0 55-0 13-6 0-10 0-8 0-2 'A *0-6 0-2 500 3-5 3-2 55-0 13-5 ^ 6-10 0-8 0-2 'A *0-6 0-2 530 3-7 3-4 55-0 3-0 2-10 50-0 12400 14000 15100 3-4 3-1 55-0 14800 17500 18700 3-5 3-2 55-0 17400 20800 22700 3-8 3-5 60-0 19200 21900 24900 3-1 1 3-8 55-0 22400 27100 28700 4-2 3-11 60-0 26600 32000 34500 4-6 4-2 60-0 31300 37200 40100 4-8 4-4 60-0 35000 41 900 45100 ISO lb American Standard Drilling. 300 lb American Standard Drilling. Fuel burning rates based on 150,000 Btu oil. Low Pressure Boilers furnished with openings for Oil Heater and Temperature Control. High Pressure Boilers furnished with openings for Oil Heater and Injector. Overoll Height is increased IV2" when steel skids ore furnished. SAFETY VALVES--Boilers over 15 lb swp--Number and size varies with valve setting. All boilers having 500 sq ft or less of heating surfoce furnished with one valve. Boilers having more than 500 sq ft of heating surface furnished with two or more valves. Manufacturer reserves right to use separate outlets or yokes as conditions require. Boilers 15 lb swp--One or more valves furnished depending on required capacity, regardless of boiler heating surface. STANDARD EQUIPMENT (15-125-150 lb STEAM)--Steel saddle supports, refractory lined rear combustion chamber factory installed. Flue cleaner and handle. Washout plug socket wrench for 15 lb boilers only. STANDARD TRIM (15-125-150 lb STEAMJ-Safety valve(s) as required by A.S.M.E. Code, steam gouge with syphon ond cock, water column, water gauge valves, glass, guards and three try cocks. Chain operated water gouge valves and try cocks with boilers HM-884, LM-884 and larger. NOTE--For 125 and 15Q lb steam boilers: Globe and check valves for feed line, quick action and slow action blow-off valves are furnished. STANDARD EQUIPMENT (Water Bailers)--Steel saddle supports, refractory lined rear combustion chamber factory installed. Flue cleaner and handle. Washout plug socket wrench. TRIM (Water Boilers)--None furnished. Additional equipment or trim at extra cast. Choose KEWANEE and You Get More ... Look Inside and See UD *'** "V . ! VJ y SHEll shaped from heavy flange steel with heads and furnace of firebox quality. Greater strength insures longer life. B MANHOIE 11" x 15" in all boilers and washout open ings provide accessibility to waterside. STEAM SPACE . . . generous steam space for ample reserve of dry steam to take care of unusual and sud den demands. STEAM DISENGAGING AREAS are long and wide so steam bubbles move up into the steam chamber with out turbulence. REAR COMBUSTION CHAMBER is heavily lined with refractory. Boilers for high pressure incorporate dry back design. Low pressure boilers designed with water back top. Sectional rear cover plate with observation port and access opening to fusible plug. FIRE TUBES, 3" in diameter of heavy gage steel, ex panded into holes with ends firmly rolled and beaded. M-800 shown with skids furnished ot extra cost Long GAS TRAVEL, through the lengthy combustion chamber, then back through the full length of the fire tubes, transfers all usable heat to the boiler water. H CORRUGATED FURNACE for extra strength and add ed heating surface next to the fire. Its generous size provides plenty of space for the burning fuel to mix with the air and burn completely. Low pressure boilers provided with plain circular furnace. RAPID CIRCULATION through the wide, unobstructed waterways sweeps steam bubbles up without commo tion. M-800 is cf very fast steamer. Sturdy steel SADDLE SUPPORTS require no special base construction. Steel skids shown in cut-away illus tration above, furnished at additional cost. Substantial hinged FLUE DOORS, gasketed for per manent gas-tight fit, provide easy access to fire tubes for cleaning and inspection. M Gas tight SMOKEBOX of heavy gage steel . . . welded in one piece to boiler shell. Rectangular smoke out let located at top. SQUARE FEET OF HEATING SURFACE per Horsepower of Boiler Rating The M-800 Series, like every Kewanee boiler, has been designed on S.2 square feet of heating surface for each horsepower of its rated capacity, which is in strut accord ance with the time-tested and proven code established by the Steel Boiler Institute. This proper proportioning of primary and secondary heating surfaces to the volume of water in the boiler comes only as a result of many years of experience and continual testing to find out just what is right. Kewanee's 84 years of experience can't be matched! 28808 M-800 A GREAT TEAMMATE FOR ANY QUALITY OIL, GAS OR COMBINATION OIL-GAS BURNER nr# v>; . ---- The Kewanee M-800 Boiler is ideal for use with any quality Oil, Gas or Combination Oil-Gas Burner to form a complete Boiler-Burner Unit. A few of the many features which make this boiler so adaptable to Boiler-Burner Units are . . . complete range of sizes for both high and low pressures . . . unusual strength and dependability . . . ability to pro duce far above rated capacities at highest efficiencies . . . greater heating surface . . . ease of cleaning and inspection . . . steel skids that eliminate special base construction . . . only two or three matching connec tions to make in mounting burners to boiler frame. KEWANEE-ROSS CORPORATION Division of American Rodiator & Standard Sanitary Corporation KEWANEE, ILLINOIS Three Boiler-Burner Units de veloped using the M-800 Series are shown above. For additional information on these units, write for separate catalogs. 28809