Document 0geYZoE5334kOma3J0R24re4J
CO</~ 009?
INTERNAL
CORRESPONDENCE
UNION CARBIDE CORPORATION i m :mmh mi mu m
I'M | ( JX hi II } ' ' if II I II If .1 l/.i J:
PLAINTIFF'S EXHIBIT UC-4309
ii ; . (ii
H. E. Rucker 512/2009
"v" B. H. Avashia, M.O. - 512/23 J. W. Barna - 2009/6 W. L. Browning - 2009 R. E. Coyner - 2009 C. P. Maxwell - 701/2 B. R. McMakin - 2009
September 28, 1987 'EM&TS - HS&EA
Industrial Hygiene Asbestos Exposure Monitoring
Attached are the results of the nine days asbestos monitoring on insulators at the Institute Plant while removing asbestos from approx. 715 feet of pipe at the Cellosize Unit, Building 79 piperack. The area was barricaded and amended water was used throughout the abatement process. An enclosure was not used. The reasons for not enclosing the job were documented and subsequently reviewed by the UCC Law Department and Industrial Hygiene Department in Danbury, CT.
Only one of the 21 personal samples exceeded the 0.2 fiber/cc permissible exposure level of 0SHA standard 29CFR 1926.58. Six of the 21 personal samples exceeded the 0.1 fiber/cc action level of the same standard. None of the four area samples collected outside the barricade exceeded the action level of 0.1 fiber/cc of this standard.
Employees wore no street clothes, two pair of coveralls, headcovers, boots, gloves and A0 R57-A HEPA half-face cartridge respirators.
Please inform of the monitoring
results as soon as possible. Have them sign and date this report and return to M. A. Patel at 511/701-330.
UCC 011348
Asbestos Monitoring - cont.
-2- September 28, 1987
If you have any questions or we can be of further assistance please call us on extension 3750 or 6485.
WORK BY:
APPROVED BY:
H. U. Kimble & V. E. Stover
Attachment
VES:MAP:rab 2717P
Manhar A. Patel /
UCC 011349
AS8EST0S EXPOSURE MONITORIN3
Conp. Ref. W2299 W2300 W2301 W2302 W2303 W2304 W2305 W2306 W2307
Date 6-30-87 6-30-87 6-30-87 7-1-87 7-1-87 7-2-87 7-2-87 7-2-87 7-6-87 7-6-87
Sanple Type/ Enployee Name
Sanpl ing Time
Air Cone, fibers/cc
TWg fibers/cc
COTENTS
421 min.
0.053
422 min.
0.134
422 min.
0.074
428 min.
0.058
428 min.
0.083
428 min.
0.025
427 min.
0.025
426 min.
0.072
420 min.
0.056
422 min.
0.083
0.046 0.118 0.065 0.052 0.074 0.022 0.022 0.064 0.049 0.073
Stripped approx. 100 feet of 1-inch steam line at Building 79, Cellosize piperack.
Stripped approx. 100 feet of 1-inch steam line at kiilding 79, Cellosize piperack.
Stripped approx. 100 feet of 1-inch steam line at Building 79, Cellosize piperack.
Stripped approx. 60 feet of 1/2 and 1-inch steam line at Building 79, Cellosize piperack.
Stripped approx. 60 feet of 1/2 and 1-inch steam line at Building 79, Cellosize piperack.
Stripped approx. 100 feet of 1/2 and 1-inch steam line at Bldg. 79, Cellosize piperack.
Stripped approx. 100 feet of 1/2 and 1-inch steam line at Bldg. 79, Cellosize piperack.
Stripped approx. 100 feet of 1/2 and 1-inch steam line at Bldg. 79, Cellosize piperack.
Stripped approx. 85 feet of 1/2 and 1-inch steam line at Building 79, Cellosize piperack.
Stripped approx. 85 feet of 1/2 and 1-inch steam line at Building 79, Cellosize piperack.
UCC 011350
ASBESTOS EXPOSURE MONITORING (continued)
Carp. Ref. W2299 W2300 W2301 W2302 W2303 W2304 W2305 W2306 W2307
Date
Sanple Type/ Enployee Name
Sanpling Time
Air Cone, fibers/cc
TWAg fibers/cc
COMMENTS
7-7-87
7-7-87
7-7-87
7-8-87
7-8-87
7-8-87
7-13-87
7-13-87
Area
7-13-87
Area
7-14-87
7-14-87
423 min.
0.140
423 min.
0.199
423 min.
0.052
424 min.
0.035
422 min.
0.263
423 min.
0.136
410 min.
0.163
409 min.
<0.007
408 min.
0.010
425 min.
0.026
425 min.
0.053
0.125 0.176 0.046 0.031 0.231 0.119 0.140 0.023 0.047
Stripped approx. 100 feet of 6-inch line at Building 79, Cellosizet piperack.
Stripped apprqx. 100 feet of 6-inch line at Building 79, Cellosize piperack.
Stripped approx. 100 feet of 6-inch line at Building 79, Cellosize piperack.
Stripped approx. 100 feet of steam condensate line at Building 79, Cellosize piperack.
Stripped approx. 100 feet of steam condensate line at Building 79, Cellosize piperack.
Stripped approx. 100 feet of steam condensate line at Building 79, Cellosize piperack.
Stripped approx. 90 feet of steam condensate line at Building 79, Cellosize piperack.
Breathing zone level at west side of barricade 1-foot outside.
Breathing zone level at east side of barricade 1-foot outside.
Stripped approx. 80 feet of 6-inch line at Building 79, Cellosize piperack.
Stripped approx. 80 feet of 6-inch line at Building 79, Cellosize piperack.
UCC 011351
>
ASBESTOS EXPOSURE MONITORING (continued)
Corrp. Ref. W2299 W2300 W2301 W2302 W2303 W2304 VC305 W2306 W2307
Date
Sanple T)pe/ Employee Name
Sanpling Time
Air Cone, fibers/cc
TWs fibers/cc
COMMENTS
7-14-87
Area
7-15-87
7-15-87
7-15-87
Area
428 min. 427 min.
0.013 0.218
429 min.
0.058
430 min.
0.063
0.194 0.051 -
At breathing zone level 1-foot west of barricade.
Stripped approx. 100 feet of 6-inch line at Buildihg 79, Cellosize piperack.
Stripped approx. 100 feet of 6-inch line at Building 79, Cellosize piperack.
At breathing zone level 1-foot east of barricade.
UCC 011352
I