Document 0gQRDnvDY5p8bg7yax59VRy4R
r i
_-r*
*
v\.u ;u
PKO`-' (NAME fi LOCATION!
OATE
SUBJECT
REFERENCE,
TO
W. G. Krummrich
July 7, 1969
S~1 Odor - Chemical Service
Dan Roman . Harry Yapp H. J. Horner
s&'i.-M I
Samples of Santophen-1 and Chlorophen-1 received from Chemical Service, Division of IMGCO-GATEWAY Corporation, Baltimore, Md. were checked for possible sources of mercaptan type odor.
The samples were fused with metallic sodium and qualtitative tests for sulfur performed. The Santophen-1 showed the presence of sulfur, which was expected because of the thiourea inhibitor. Chlorophen-1 did not show any sulfur present. An additional method for sulfur involving the reduction with Raney-nickel, evolution of H2S, and formation of the methylene , lue complex did not show the presence of sulfur in Chlorophen-1. This method is sensitive to tenth's of a ppm.
A G.L.C. analysis of both samples showed a
difference of about 5:1 in one impurity. This
material is higher boiling than o-benzy1-p-chloro-
phenol and was more concentrated in the chlorophen-1
material.
.
.
Isolation and identification of this impurity would require considerable effort. (> 10 man-days).
If additional work on this problem Is requested, please inform and assign priority.
. QG
J. Roth
dv
f
DSV\f 298986
IN- IO REV. 11 45
STLCOPCB4068899
REAGENTS:
Benzophenone (Marker) HexamethyIdisilazane (HMDS) TrimethyIchlorosilane (TMCS) Tetrahydrofuran (THF) SE 50 Silcone Chromosorb G AW DMCS Treated
Fisher Scientific B-270 Pierce Chemical Company Stock No. 847704 Pierce Chemical Company Stock No. 85550
Pierce Chemical Company Stock No. 278604 Wilkens Instrument and Research Company Varian Aerograph
EQUIPMENT:
Varian Aerograph Model 1820 GLC Varian Aerograph
. Varian Aerograph Model 50 Recorder with disc integrater
-,t SS column 6' long packed with 5$ SE 50 on 70-80
chfOtnosorp u AW PMcs treated:
Syringe 50 ul
#705 Hamilton Company
Syringe Luer 1 and 5 cc Fisher Scientific 14-820
INSTRUMENT CONDITIONS:
Detector Block Temperature 525c
Injection Port Temperature 510 C
Detector Voltage
150 Ma.
Helium Flow
60 cc/min.
Helium Back Pressure
10 lbs.
Column Temperature
Start 7._5C Finish _520C_
Program immediately @ 10c/min. Hold until all comp. elute
Column Teirperature limit control 550C
DETERMINATION:
Using an analytical balance, weigh 0.55 0.05 grams of sample to the nearest 0.0001 gram into a 20 ml. serum bottle. Add 0.2 grams of Benzo phenone marker, weighed to the nearest 0.0001 gram, to the serum bottle.
Add, by pipet, 2.0 ml of tetrahydrofuran and swirl to dissolve the sample.
Using a 1 ml. syringe add 0.5 ml. trimethylchlorosilane. Swirl to mix.
Using a 5 ml. syringe add 5.0 ml. hexamethyldisilozane to the serum bottle swirling the bottle while adding the HMDS.
Stopper the serum bottle and insert a #20 syringe needle through the stopper
for a' vent. Place the bottle in a 75C bath for 50 minutes. Swirl
occasionally to help complete the reaction. Remove from bath at the end of
the 50 min. period and swirl vigorously. Allow to settle.
`
Inject a 10 ul sample of the supernatant liquid into the GLC.
Program immediately at 10c/min.
'
Attenuations will have to be determined according to the materials present
In the sample.
.
oSMM298981
STLCOPCB4068900
-2 -
.&") i
Correct peak areas for base line drift.
CALCULATION;
$ Component =
Area Comp. Area Marker
X
Wt. Marker Wt. Sample
X Comp. ACP X 100
Area correction fa :tors for each component "are determined by weigfv'r'g given amounts of pure reagents and running several chromatograms per standard sample. The average value of each component was used as the
AFC.
AFC
Weight Comp. Weight Marker
X
Area Market Area Comp.
Note:
This analytical procedure was developed for a special project by the WGK Process Research and Development Group. Its precision and accuracy have not been determined. Accordingly this analytical procedure is not recommended for routine analytical use, particularly Assay of Santophen 1.
"The- information contained herein is, to our best knowledge, accurate; but all recommendations or suggestions are made without guarantee, since the conditions of use are beyond our control. Monsanto disclaims any liability for loss or damage incurred in connection with the use of the above."
STLCOPCB4068901