Document 0gLkYM6m4BnRLeYvK0QKDmVRJ

Air Conditioning, Automatic Heating Systems The Henry Furnace & Foundry Company Manufacturers of MONCRIEF Furnaces & Air Conditioning Systems 3471 East 49th Street Cleveland, Ohio Phone Michigan 9322 Moncrief 'Aristocrat" Air Conditioning System --for coal, hand or stoker fired. The Moncrief Aristocrat Air Conditioning Unit is made in two Series, " C" for cast iron and "S" for steel, riveted and welded. The Series "S" unit up to and including the No. 2456 is in. boiler plate construction. All larger steel units are made of M in. boiler plate. The equipment consists of a quiet operating blower, a patented windbox (exclusively Moncrief) which distributes the air evenly and at a high velocity over the -heating' surface, Minneapolis-Honeywell Thermostat, damper motor, blower and high limit control, automatic humidifier, and air filters. The casing is well designed and is furnished' in red and black crackled enamel finish. Dimensions, Capacities and Data of Moncrief Aristocrat Coal Fired Air Conditioning Units C SERIES -CAST FURNACE NUMBER size or ca. IN& WTT 4OUT 6LOWER M01> IXMGT) *ifrm SIZt 6f (ai NO WITHX RSELAO... amrt* Marne NOTH LtNGD K06HT worn size 4020 40 40 41* 40 73 41% 74 no 4422 42- 34* -41% 42 72ft 41% 76 1(2 4624 44 40 41% 44 74 5224 44 44 42% 44 6o 41% 80 42% 62 112 112 5426 46 46 42% 46 64* 42% 64 114 4055 54 57 /s 54 99 75 94 214 10T0I IIHP tttTt CASU6 sunna AREA met SQ IKS SA9G 3QIN5 C/M naif B*rru MAUfU IffiM &<n fwccoair roeccoAiR SfiortR sii BUSES HTU two-fun OHKfrmX Mcestrai Mtwnuu GRAVITY GftMTY mats BIl VUfiL 5400. RATIO ft 5021 214 336 347 350 2 73&00 65200 55200 401 7544 ft 5409 249 474 1157 350 3 66300 101800 44000 476 ?oas ft 4010 324 547 1330 350 3 101.400 112300 75600 5.V 1645 ft 4753 397 450 1560 350 4 120.400 I39D0O 90000 455 >700 ft 7579 472 757 1640 350 5 140,300 142000 104600 747 1404 10920 70S 1115 2710 350 4 204,400 234400 I54S00 1106 1X50 5 5CRIE5-STCEL 2 0 54 2254 24S4 2 758 3040 3040J 34 4 2 34-4 2J 40 40 40 40 46 52 46 52 40 41 % 40 43 41% 40 44 4 1 % 40 51 42% 40 54 46% 46 54 48 ft 52 40 46ft 46 40 46ft 52 90 41% 97 4 1 % too 4 1% 104 42% 109 48* 109 46 % 120 46ft 120 46ft 74 74 74 74 64 66 90 94 110 1 12 1 12 1 14 212 212 2 14 214 ft 4224 214 ft 4499 249 ft 4940 330 ft 6064 434 ft 10041 SS7 ft 11460 552 440 1070 350 504 1232 350 565 1424 350 747 1615 350 925 7740 350 971 7347 350 7 3 4 5 5 5 61.400 94200 94000 108.400 136,400 171.000 160300 I4QOOO 206000 ft% 11245 730 1 137 2800 350 4 213600 12364 730 1 190 2695 350 4 221200 255200 40900- 442 (03500 737 145200 >201. J497 With blower on side use dimensions length and height under size of casing without blower. C.F.M. is based on 70 deg. room temperature and 135 deg. register temperature. For heating capacity 2 per cent was added for each square foot of heating surface above ratio of 20 to 1 and 2 per cent deducted for each square foot below ratio of 20 to 1. Heating capacities are based on a 7 lb. combustion rate using 12,000 Btu coal and efficiencies of--65 per cent at bonnet, 85 per cent register for fan coal hand fired--75 per cent at bonnet, 85 per cent at register ' for oil or stoker fired (oil--140,000 Btu and 0.55 gal. per sq. ft. grate per hour)--55 per cent bonnet! 75 per cent at register for gravity hand coal fired. Gravity pipe area equals 1.75 X grate area [1.00 + .02 (R - 20)]. If 6 lb. combustion rate is desired for prolonged firing period deduct approximately 15 per cent from forced air Btu ratings. Maximum velocity through filters. 200 feet per minute. The Anthracite Winter Air Conditioner consists of a MONCRIEF Unit and a Miles Combustion Modulator. The outside temperature is correlated with the warm air temperature- to affect a Graduated Room Temperature, 68 deg. in mild weather and 78 deg. in zero weather. Constant Modulated Heat Supply eliminates COLD 70 and complicated control equipment. Write for particulars. Note: This unit can be made with either the Moncrief Cast or Steel Aristocrat Air Conditioner. 862 Henry Furnace & Foundry Air Conditioning, Automatic Heating Systems Dimensions and Capacities of Moncrief "Special" Oil Fired Air Conditioners Unit No. 75 100 Input Gallons per hour............................ Size of casing: Heating surface--sq. in............................ C. F. M.......................................................... Btu Del- at Register................................. 3/* 28* 703/4* 60* 110 1/6 6120 800 2 73.000 1 28* 703/4* 60* 112 V* 6120 1100 2 100.000 Moncrief "Aristocrat'' Oil-Fired Air Conditioning System Moncrief tlCBF" Gas Air Conditioning System The Moncrief Gas Air Conditioning Unit is a cast iron heater, designed to bum efficiently, mixed, artificial or natural gas. It is equipped with a quiet operating blower, air filters, thermostat, blower and high limit control, automatic humidifier, motor valve, pressure regulator, shut-off cock and automatic pilots. It is furnished in a well designed casing with manifolds enclosed, and finished in green crackled enamel. Controls are Minneapolis-Honeywell. The Moncrief Special Oil Fired Air Con ditioner, designed for small homes--% and 1 Gal. Per Hour Input--and Moncrief Aristocrat Oil Fired Air Conditioning units--designed for larger homes with cor respondingly larger oil input--Both welded steel, %6 in- boiler plate. These units are compact, finished in Red and Black Crackled Enamel, with en closure for burner, supplied with automatic humidifier, air filters, quiet operating blower and adjustable blower control. They are made for use with standard types of oil burners and are supplied less burners and burner controls. The Aristocrat model is equipped with special patented windbox supplying a directional flow of air over all heating surfaces. Moncreif Air Conditioning Unit for 1937 is being improved in style and these new styles will be shown in literature which may be had on request. Dimensions, Capacities and Data of Moncrief Gas Furnaces and Gas Air Conditioning Units | MOTOR HPj Size or CASINGS IN INCHES FURNACE lYPtti imb AN0 LESS ItVU TYPE C LESS WITH ryptB TYPEC or MA. size FLUE GAS NUMBER TYPC.C W01> SLOWER AONtfi BUMER HEIGHT LttSTW LENETt LENGTH ItftHT BURTCRS PIPE UNC CASOX > j| FREE Ur oS AREA ll BTU. INPUT TOEDAS BDJ AT CfM t REttSTCR 3m 50 100 1 50 zoo- 1? 19 74 34 44 46 44 51ft 72 51% 54 44 51ft 72 51% 54 44 51ft 72 51% 54 1 2 5 4 3 % 2160 233 30,000 4 1 4320 376 215 4Q000 42750 540 110 5 1 6480 458 277 9Q000 64125 840 110 4 1 8640 584 277 120000 85500 1120 112 250 41 3 00 49 44 51ft 72 51% 54 44 51ft 74- 5I%- 54 5 4 7 IX 10800 730 277 150000 106875 I400 112 8 IX 12960 976 246 180000 128250 1480 114 350 54 44 51ft 74 51% 54 7 6 IX 15120 1146 244 210000 149425 1940 114 400 44 450 71 44 51ft 77 51% 54 44 '51ft 72 51% 54 6 9 Ift 17280 1166 277 240000 171000 2240 212 IO IX 19440 1314 274 270000 192250 2520 212 500 78% 44 5tft 74 51% 54 GOO 94ft 44 51ft 74 51% s4 10 II K) . ITS 2I60C 1376 293 300000 213750 2600 214 10 Ift 25920 1676 266 340,000 254SOO 3340 214 Ovi rs GRAVITY GfiAflTY 35 ! BIUAT PIPE 5c z ROSTER AREA 19125 170 ft!4 2 105 38250 281 2 156 57375 - 422 X 3 140 74500 542 * 4 131 95425 703 r 4 156 114750 844 ft>s 5 147 133875 984 5 I4&I 153000 1124 ftft 5 163 172000 1245 6 175 191250 1404 X 6 210 229560 I486 Type B furnace casing has manifold exposed and is designed for gravity use. Blower and filters can be added as separate unit. . ... Type C furnace casing has manifold enclosed and is designed for blower-filter use. Can be used for gravity circulation if desired. Forced air Btu ratings are based on efficiencies of 75 per cent at bonnet and_95 per cent at register Gravity Btu ratings are based on efficiencies of 75 per cent at bonnet and So per cent at register. C.F.M. capacities are based on 70 deg. room temperature and 135 deg. register temperature. Add 11 in. to overall height for 14 in. pitched top used with Type B casing. 863