EQUIPMENT AND PROCEDURES FOP. MOUNTING MILLIPORE FILTERS
AND COUNTING AS3ESTGS FIBERS
BY PHASE CCNTRAST MICROSCOPY
i
Stephen G. Bayer Ralph D. Zumwalde Thomas A. Brown
4
Bureau of Occupational Safety and Health 1014 Broadway .
Cincinnati, Ohio 45202
JULY 1969
U. S. DEPARTMENT OF HEALTH, EDUCATION, AND WELFARE
Public. T!rc!J; Scrvlc* Cor.funcr Protection rod ri.vlros.-'.rntal Health Service
Environmental Control Administration
TX GARRETT
. v*
TABLE 07 CONTENTS
* .
IHTRODUCTTON
EQOTPMEKTLTST '
LABORATORY SET-OP
-
PRELIMINARY MICROSCOPE SET-UP
MICROSCOPE SET UP AND THE PROCEDURE FOR OBTAINING KOKLER ILT.ITMINATION
4 DETAILED INSTRUCTIONS FOR BAUSCH AND LOHB BINOCULAR MICROSCOPES
FILTER MOUNTING Set-uo prior to mounting
Mounting procedure
MICROSCOPE PRECAUTIONS AMD MAIKTEMAKC.E
COUHTTKG PROCEDURE
*
FIELD MONITOR DISCUSSTOW
.
* CftUJULATlUN OK CONCENTRATION
ADDRESSES
1 2 -2 3
5 8
9 10 11 12 13 14
17
TX GARRETT
004221
RMC0000058
FOREWORD To determine concentrations of asbestos dust in air for compari son with established hygiene limits, a simple reproducible method is required. A simple and inexpensive sampling method uses disposable (reloadable if desired) plastic membrane filter holders, pre-loaded with membrane filters. These membrane filters may be rendered transparent and
* the asbestos fibers counted with a phase-contrast microscope at 430X (or 400X)* This method has been used by the Asbestosls Research Council in Great Britain and the U. S. Public Health Service in the United States of America. It is specified in the proposed change for asbestos in the 1968 threshold limit values of the American Conference of Governmental Industrial Hygienists.
Uniform procedures must be used for carrying out these counts if reproducible results are to be achieved. Detailed equipment and proce dures used by the U. S. Public Health Service are described here.
004228
*
-1-
INTRODUCTION
For several years, a set method for counting and sizing airborne particulate matter, which has been deposited upon membrane filters, has been used. The filters used in this technique are 37 mm diameter cellu ! lose ester membrane filters manufactured by Milllpore Corporation, (cat.
u no. AAWP03700). The slide mounting technique refers only to these filters, and will not work for any others.
The filters may be purchased premounted in convenient field monitor cases, and are ready for sampling. The filters are nearly 100% efficient for any asbestos dust, even for fibers with d.iameters much smaller than the 0.8 micron (p) pore size. Sample preparation for electron and optical . examination are both relatively simple. Slide mounts of the filters ere semipermanent.
The following procedures and recommendations will produce accurate results. If each step is performed exactly as indicated.
TX GARRETT
004229
RMC0000060
- 2-
EQUIPMENT LTST
1. Table 2. Adjustable chair
3. Phase contrast microscope
4. Ribbon filament illuminator or (built-in illuminator)
5. Eye piece reticle (Porton type)
^
6. Lens tissue
7. Small camels hair brush
8. Slides
9. Cover slips
10* Spatula
11. TWeezers
12. Scalpel
13. Wheaton Balsam bottle
LABORATORY SET-UP It is important to provide a suitabl e counting area, for the room
in which the counting is to be dene has a great bearing upon the mlcroseonist. It should be out of the way of normal traffic, and be kept as free from duet and smoke as possible. The tables on which the microscopes are placed should be oe free from ribretione awd shocks as possible. /,n adjustable chair will do much to add to the comfort of the counter.
TX GARRETT
004230
RMC0000061
-3-
PRELIMINARY MICROSCOPE SET UP Before any dust sizing or counting can be done, proper equipment
mist be at hand. This section describes the required equipment. The illuminator should be small and reasonably compact. Ribbon
filament illuminators are generally much easier to use. The illuminator must incorporate a condensing lens, so that the enlarged image of the
4 lamp filament may be focused in the plane of the substage condenser diaphragm. The illumnator must also have an iris diaphragm located as near as possible to the condensing lens. The iris serves as a field diaphragm and is focused in the plane of the specimen.
The microscope used must have a substage condenser fitted with an iris diaphragm. This iris serves as an aperture diaphragm. The a mlcroscooe should have a calibrated reticle inside the non-adjustable eyepiece. The reticle should be small enough that all the counting field is in focus (if the flat field objective and eyepieces are used, essentially . the entire field will be in focus). The microscopes must be equipped with phase contrast accessories. Using phase contrast, even objects with almost , the same refractive index as the mounting media can be seen. Light waves which travel through such a specimen are retarded by a fraction of a wave length to produce a change in phase. The phase contrast optical system reveels these phase changes as light or clerk contrast against the back ground .
This procedure was written by a user of B.iusch and T.c;i.b phaseequipped mfcroscooes, so that microscope set-up procedures correspond with
GARRETT
004231
RMC0000062
-4
* "..............................................................
these. However, any good mieroscooe with phase contrast accessories will
be satisfactory.
For continual routine examination of filters, the binocular type
microscope is much more comfortable. The use of a first surface mirror
I is recommended, but not necessary. By utlizing a second surface mirror, multiple Images of the Illuminator field iris are formed which will detract
from the crisnness of the final image.
A
As mentioned orevlously, the microscope must contain a reticle.
Any reticle, such as the Porton or Patterson Globe and Circle, which
projects a constant counting area and has provision for sizing, will
work. The Porton reticle which we use outlines a rectangle that fits
easily within the periphery of focus. The rectangle Is divided Into two
squares. The left square is divided into 6lx rectangles which constitutes the counting area. Above and below the large rectangle are a series of
circles In which every other circle doubles in diameter. Hence the third is twice the diameter of the first; the fourth is twice the size of the
1
second, etc. The right half of the rectangle contains a scale for extending
the size above the number nine circle. The formula D*L 2 describes
the circles sizes. The diameter I) is found from L which is the unit of length,
and N which represents the number of the circle. L is determined by cali
bration with a stage micrometer. The entire length of the rectangle is
?00 L units. By measuring the length end dividing by 200, L is obtained
and the circle sires may he calculated. Whenever a microscope is disassembled
or cleaned, the reticle calibration should be checked. Another fact to tale
TX GARRETT
004232
-....... RMC0000063
i
* -5- '
Into consideration Is that changing the interpupillary distance of the
binocular will change the calibration, so the microscopist may want to
check the calibration at both extremes of adjustment. The counting area
on the reticle should be kept as clean as possible, as dirt on the reticle
Is In focus and may be counted.
--
4 MICROSCOPE SET-UP AND THE PROCEDURE FOR OBTAINING KOHLER ILLUMINATION
By utilising equipment that meets the requirements Just mentioned, any counter may achieve comparable counts after some practice. This section will deal with setting the microscope up and obtaining Kohler Illumination. It is extremely important that, every step be followed exactly as indicated. 1. Place the microscope on a flat, level surface at a height such
. that the eyeoieces may be observed without strain or discomfort. 2. Place a moderate dust sample upon the stage. 3. Place the illuminator directly in front of the microscope. Sight across the two and be sure they are aligned. For coil filament bulbs the illuminator iris should be ten inches from the center of the microscope mirror. For ribbon filament bulbs, the front of the filter holder should be seven inches from the center of the plane side of the mirror. Never use the curved side. 4. Remove, all diffusing filters fro.n the system and insert a neutral density filter and a clear blue filter. Blue or greeu colored filters may be used at the discretion of the microscopist.
TX GARRETT
004233
RMC0000064
-6 MOTE: Where the microscope includes a built-in illuminator to give Kohler illumination, the above steps will not all be necessary.
REVIEW A. Check microscope and illuminator alignment,. B. Check the distance betveen the microscope and the illuminator.
A
C. Be sure that you are using the flat side of the mirror. 0. Make sure that there are only two filters in the system.
5. By means of the focusing knob on the side of the substage con denser assembly, raise it until the upper lens nearly touches the botton of the slide. Remember that the free working distance of the condenser is in the order of 1.2 am and that the slide is about 1 mm thick.
6. Turn on the illuminator. Using the tilt controls, direct the beam onto the center of the mirror. Then, by tilting the mirror direct the beam upward into the condenser.
7.~ Close the substage iris completely. Open the illuminator iris all the way,
8. By means of the focusing controls on the side of the illuminator, focus the image of the filcment on the botton of the substage iris. This may be done by leaning over the microscope and observing the subnfage iris in the microscope mirror. (On such models as the Bausch & Lomb PIl-27, there is a fine focus knob at the rear of the illuminator). In that case, move the condensing lens all the way forward end trim the focus with the fine focus knob.
TX GARRETT
004234
RMC0000065
t" w_
- 7-
9. Open the substage iris about half vay.
REVIEW
A. Cheek the distance between the slide and condenser.
B. Be sure that the beam is striking the center of the mirror, and
that it is being deflected upward Into the condenser.
C. Please repeat step 7.
A.
D. Check step 8. If the image is not in focus now, correct it. Do not
continue until the filament is correctly focused.
E. Please repeat steo.9.
i
10. Put the 10X objective in place and focus on the sample. This
la done as follows: First, looking from the side of the
microscope, lower the objective until it gets very near to
the slide. Then, by looking through the eyepieces, focus up.
Never focus down with coarse focus when looking through eyepieces.
A word of caution; The objective lenses are very expensive, so be careful
not to grind them through the slide. Always focus up. Now trim the focus
with fine focus knob. Focus sharply on the sample. Secondly, close the
field iris fully. If the condenser is nearly in focus, you should see a
bright spot of light. By using the condanser focus knob, bring the field
iris into sharp focus. Now, both the field iris and the objective are in
focus on the r.s:.->le. If there appear to be multiple images of the field1-
I iris, it is because of the second suifrcc mirror. Soiac. of the light waves
are reflected from the first surface, resulting in secondary images.
i TX GARRETT
004235
RMC0000066
- 8-
12. If the Image of the field i-ris is not centered, re-center it by tilting the mirror. If the color around the field iris is not uniform, recheck the tilting of the illuminator.
REVIEW A. Check and be sure you are focused on the sample. 10X objectives have
a relatively long focal length and it may posslble'ro focus on: (a) the top of the cover slip, (b) the sample, (c) the botton of the filter, (d) the top of the slide, (e) the bottom of the slide. (f) the top of the condenser. So be sure of the focal plane. B. Be sure that the field iris is focused in the sample plane. Check this often vhen examining samples. As the sample focus changes, so - does the condenser focus.
4
C. Recheck the centering and tilt of the illuminator. DETAILED INSTRUCTIONS FOR EAUSCH AND LO?tB BINOCULAR MICROSCOPES 1. Leave the microscope phase rind on 0. Insert the telescope that is supplied with the kit into the right eyepiece tube. Focus on the dark phase ring. Open and close the substage iris to be sure that it is centered in relation to the objective phase ring. If it is not in the center, loosen the set screw on the condenser mount and properly seat the condenser. Then re tighten the set sere::. This should very seldom be necessary. Do not force anything, and be careful and patient. When you are satisfied that the condenser is aligned, open it all the way, 2. Turn the Dbssc* wheel to 10. This shows that the 10X phase
004236
TX GARRETT
RMC0000067
t-
\
-9 -
ring is in place. Look through the telescope again. By using
the adjustment screws on the side of the condenser, move the
rings until they are perfectly concentric. When changing phase
rings, move them carefully, so as not to knock the condenser
out of alignment.
3. Turn to the 43X objective. Carefully turn the wheel to the
43 phase ring. Align the two rings in the same manner as per
formed in step 2.
4. Remove the telescope and replace the eyepieces. Again, check the
condenser focus. You are now ready to examine the sample at 430X,
I
assuming that you are using 10X eyepieces.
I
t FILTER M0UKTT1TG
'
t Set-up Prior to Mounting
Have available at hand a quality scalpel and a supply of no. 10
curved blades, a pair of tweezers (fine pointed are preferred), a spatula
or fire polished glass rod and a box of lens tissue. Slides (1" x 3" or
25 x 75mm) with frosted ends are best because one may label the slide with I
the date, sample number, etc. It is advisable to use quality number 1-1/2
cover sllp3. Kost dry objectives are corrected for this thickness cover
glass. The mounting media should be kept in a Wheaton balsam bottle. The
edge around the lid should be coated with stopcock grease to keep out the
surrounding air.
The mounting solution may not* be pi-cpared. A one to one solution by
volume of dimethyl phthalate end diethyl oxalate is poured into the balsam
TX GARRETT
004231
RMC0000068
10 bottle. Then add 0.05 gram of filter material for each milliliter of
solution. . The added filters increase the viscosity of the solution.
Before using the solution, all of the filter material must be dissolved
and the solution must be of uniform consistency. This may require a day
or so with frequent stirring. Refrigeration may add to the shelf life
of the solution. ' Mounting Procedure
A
Keep in mind that cleanliness is important. First, lay down two
pieces of lens tissue; one directly in front of you and the other to the
left or right for the mounting tools. Next, wipe the scalpel, tweezers
and glass rod or spatula with lens tissue. Holding a slide by the frosting,
wipe it clean. Lay it down with the frosted end toward you. Even pre
cleaned slides must be cleaned this way. Hold a cover slip by the edges
between the index finger and the thumb, and clean it in the same manner as the slide.
Place the cover slip so that one edge rests on the unfrosted end
of the slide and the other edge rests on the lens tissue. Be sure that
the lower surface does not come into contact with the lens tissue.
Using the glass rod, or dropper, dispense a small drop of the mounting media onto the center of the slide. Replace the rod or dropper
Into the solution bottle and cover It. Using the spatula, spread the
solution into a ti-inngulcr shape. While the fluid is spreading, cut a
wedge of corresponding size from the filter. Place it upon the mounting
media, samnle side up. Pick up the cover slip and place it on top of the
filter. Press lightly on the cover slip to bo sure the mounting media
has made contact with it. Label the slide before completing any other
004238
GARRETT
RMC0000069
- *. -
- 11 -
slide. Sometlne, after an hour or so, the filter may not have cleared. Usually, this can be cured by pressing lightly on the cover slip vlth a pencil eraser that has been wrapped vlth lens tissue. If the filter has been used to filter liquids or is damp, it will require drying,`for it will not clear unless completely dry. J< Use only enough solution to clear the filter. If too much solution 1 is used the sample may spread and give an erroneous count per unit area. The filter should be counted as soon as possible because the solution may eventually form crystals that look like fibers and may be mistaken for part of the sample.
After a little practice and experience, several samples may be mounted at the same time with excellent results.
Remember to keep the area in which mounting is done as clean as possible to prevent contamination of the filter. MICROSCOPE PRECAUTIONS AND MAINTENANCE
Quality lens tissue is a must. The mlcroscoplst should use it for any kind of lens cleaning. It should be as lint free as possible. It may be wrapped around the blunt end of a small camels hdir brush and used to clean the eyepieces. Never wipe the inside of the microsocpe body. If it is necessary to remove dirt from the inside of the tubes, blow it out with an aspirator bulb, Whenever you arc using immersion oil, be sure that you wipe all surfaces that xrere in contact with the oil.
Generally, solvents should not be used when cleaning lenses.. Alcohol, >
like most solvents will dissolve the lens mounting cement, which may ruin
TX GARRETT
004239
RMC0000070
- 12 -
the lens system. Xylene should be used sparingly to remove laoierslon oil.
Use e camels hair brush to clean first-surface mirrors and non-
critical lens surfaces. Nevet wipe first-surface mirrors with lens
tissue.
Avoid touching a lens surface with fingers as the fingerprint has
a tendency to etch into the lens surface.
A
COUNTING PROCEDURE
Place the sample on the stage and focus on it. Since the sample
is retained in the top ten fifteen microns of the filter, be sure that
you are focused in the proper plane. The reticle in the left eyepiece is
used to define the counting area. The reticle should be calibrated prior
to being used. The total fiber count (a fiber is anything three times
as Long as it is wide) should be at least iOu fibers, or twenty tleids,
whichever fs less. It is advisable to made as large a count as practical
to get an accurate average. If a fiber crosses the limits of the counting
field, only those crossing either or both of two adjacent sides are counted.
For example, a fiber crossing the top or right, or possibly both sides would
be counted. The sides chosen are at the discretion of the counter, but any
counter must always use the same sides. The fibers counted are estimated
as to length,using the circles at the top of the reticle. Our practice
has been to record all fibers sec-n, ell fibers longer than five microns
and all fibers longer Limit 10 microns. However, for comparison with
the ACGIH TLV (1968), only the longer than 5p fibers need be counted.
TX GARRETT
004240
RMC0000071
13
FIELD MONITOR DISCUSSION
Membrane filters may be purchases pre-loaded In plastic holders
(Aerosol Analysis Monitors). The Monitors consist of three sections.
The filter Is held between the middle and bottom sections. Between the
j membrane filter and the bottom section lies a support pad. The calibrated
i ! pump, designed to draw a known and constant supply of air. Is always
connected to the bottom of the field monitor case. When-many loaded cases
are taken Into one particular area for sampling, a blank or control filter
(meaning a loaded field monitor case) should be taken out to the area,
brought back unused and counted. This will determine what degree of general
contamination is present on the filters. We have found that banding the
! field monitor cases with cellulose bands greatly reduces the general .i
)*. contamination of the filters. The bands may be purchase from Walter H. Jelly and Company, Inc. They are white, opaque, size 41 x 25 and come
1 i packed In solution S-132. .Upon removal from the solution, the bands are
'
| slipped around the middle and bottom joints, or around all joints, depending
r
j upon whether the sample is going to be drawn through the top section plug l
hole-, or the entire top section removed for "open" sampling. The latter
procedure is recommended for asbestos dust sanpling since It results in a
more even sample distribution over the entire exposed filter surface.
Convenient i>iitsoual s*i.:pling pui.ps, sudi as those distributed by
Mine Safety Appliances Co., Willson Products Division or Union Industrial
are excellent for short term, low rate (around 2 Ipra) sampling. A sampling
pump ic connected to a 3 foot length of non-collapccble, one quarter inch,
rubber tubing with a male Lcur slip adapter (stock number Lli/I-, .available
from Becton, Dickson and Co.) inserted into the other end. This enables one to
004241
TX GARRETT ....................................................................................................... ............... .............. RMC0000072
i - 14 connect the hose directly to the case by simply Inserting the adapter into the plug hole at the bottom of the case. Field monitor cases may easily be re-used. The plugs and all
t sections are separated and placed in warm detergent water. The parts
) should be scrubbed thoroughly and rinsed in tap water. However, If the
| filters are to receive any chemical analysis, the cases^ should also be rinsed in distilled water. The cases should be allowed to dry in a cleann area (a clean room is preferable), to reduce contamination. The clean area Is equally imoortant when loading the filters into the cases. The filter pad (the thicker, fibrous disc) Is placed in the bottom section. The filter is placed directly on the pad. The middle and top sections
r are added, the case is pressed tightly together, and the top plug Is inserted. neplaceuieuL ul the bottom plug Is uut necessary. A celluluse band Is then place around the case and after the band dries, the unit is ready for sampling. Sample code numbers, etc. may be written on the band or upon the filter case, first making sure the markings can be removed when
! and if it is necessary. Additional information concerning filters and field monitors may be
obtained from Millipore Corporation. CALCULATION OF CONCENTSATION
Wien a sample is taken, pertinent information about the sample should be recorded at the sampling site. First, the sample m.'r.:ber should j be written on the field monitor case and the sample ticket. Next, enter II a description of his operation in the appropriate space. If the sample is a general air sample and does not pertain to any particular employee.
TX GARRETT
~
--:
004242
RMC0000073
- 15 -
write "general air sample" in the employee's name space. Information
about the `area may be written in the "description of operation" space.
If you have several pumos which are Identical in appearance, but have
different flow rates, it would be a good idea to assign them instrument
numbers. This enables you to keen accurate records of maintenance and
ealifbratlon. When instrument numbers are kept it is not necessary to
enter the flow rate at the sampling site. It may be entered later from
the record cards. Otherwise, enter the flow rate at the sampling site.
When a number of filters are taken into a general area a control (or blank) is taken along. This should be assigned a number and entered in the blank number space. Do not assign blank filters duplicate numbers.
When the sampling pumo Is turned on, enter the time in the "time on"
spec. While tb
i hine> ta(rn
nnfoc nf rw^rpl Jj i,,
exhaust hoods, fans, window ventilation, etc. These notes should be entered
in the "description of controls". The sampler should then sign his name
or initials at the bottom of the sheet. After sufficient time has passed, the sampling Instrument should
be turned off and the time recorded in the "time off" space. The difference
between "time on" and'"time off" space. The "total air volume" may be found by multiplying the flow rate (expressed liters per minute) by the
total tlmf* and recorded in the. appropriate, space-.
After the ram-ole has been taken, brought back into the lab and
mounted, the counting procedure is next.
The micrc-rc.o.ia must be properly set up. Place the slide to be
counted on the mechanical stage. Focus on the sample a short distance away
TX GARRETT
004243
RMC0000074
16 from the edge. Never count close to the edges of the filter because the filter will spread a little and lower the count. Now, enter the date, sample number, blank number and field area on the count sheet. The counter should Initial the form in the "Initial"space. The sized .fibers are entered from right to left across the form, first entering the >10p fibers, then the >5p fibers and finally, all fibers seen, callej) the total. After 100 fibers or 20 fields are counted and recorded, all of the verticalcolumns are added up and the totals are entered under their corresponding columns. Divide the totals at the bottom by the number of fields counted to determine the average number of fibers per size range- per field. By using Information on these two sheets the concentration in fibers per cubic milliliter may be calculated and entered In the "con." space on the count sheet.
Concentration - . <kv- Ftbcr
filter area)
Afield area) ( Semple volume) (1000)
Av. Fiber Count: Average fiber count per size range
----------- ------
Filter area:
855 tnm^ for 37 mm dia. membrane filters
Counting area: Reticle calibrated In
Sample volume: total time x flow rate, express In liters
1009:
Converts liters to milliliters
If blank': are used, subtract the average blank count of the same
size range fvon the average fiber count.
i TX GARRETT
004244
RMC0000075
17 ADDRESSES
Hilllpore Field Monitor Cases (complete) Cat. No. KAWP 03?AO
Millipore filter (W. Pads) Cat. No. AAWPO37G0
Millipore Filter Corporation Bedford. Massachusetts 117498'',
Portcn Reticle
Cat. No. 30084 Patterson Globe & Circle Reticle
Cat. No. 30083 Edmund Scientific Co. 701 Edscorp Building Barrington, New Jersey 08007
Wheaton Balsas Bottle Cat. No. 2244
Arthur H. Thomas Company Post Office Box 779
Philadelphia, Pennsylvania 19105
Adapters, hose end for 1/4" tubing to male leur slip Cat. No. LH/L
Becton, Dickinson and Company Rutherford, New Jersey
White, opaque, cellulose bands, 41 x 25 No. 28
Walter H. Jelly & Co., Inc. - ----- - - -
2622 Birch Street Franklin Park, Illinois 60131
--
Personal Sampler II!:. IT Willson Products Division Reading, Pennsylvania
Monitaire Sampler
Mine Safety Appliances Co. Pi'ttslj.i"f;li, Penn:.yl\.'.fiih
Unico Telematic Nodal C-liO U:"*ico Fnvlrcnmeutal Tt:d'.istries, Inc. Fall River, Massachusetts
TX GARRETT
004245
RMC0000076
I-------------------- 1
*
*
4
i OOOoooooo.
: PATTERSON GLOBE AND CIRCLE > .
I oooOOO
t i i
i i
I
TX GARRETT
o c ( ) ( ; ( )I ) (
V; vvyy vV....-J \
PORTON RETICLE
j( j \.
\i /
004246
RMC0000077
t
COUNT SHEET
TlCKIT
SAMPLE
TX GARRETT
004247
____ :_____RMC0000078
~~n r irTU`< i
PHASE CONTRAST MICROSCOPE
i
i
i TX GARRETT
' '
'' ....:
004248
RMC0000079
fT"
-*r_
>s4
LAMP CONDENSER IMAGED IN SPECIMEN PLANE
-(
KOEHLER ILLUMINATION
i I i tt
TX GARRETT
004249
RMC0000080
VIII. APPENDIX I
Air Sampling* Methods
In the study of asbestosls conducted by Dreessen e al, 63 midget lmpinger count data were used as an estimate of dust exposure. All of
the dust particles seen, both grains and fibers, were counted since too
few fibers were seen to give an accurate measurement. The resulting
count concentration wes a measure of overall dust levels rather than a
specific measurement of the asbestos concentration. This method was
satisfactory at that time since exposures were massive and the control
measures Installed to reduce overall dust levels also reduced the asbestos
dust levels.
As dust levels were reduced, It became necessary to measure the
biologically appropriate attribute of the dust cloud. At equal levels
of overall dustiness, the concentration of asbestos could vary considerably
from textile manufacture (75-85%) to insulation (5-15%). Furthermore,
if the limit were lowered below the 5 mppcf used previously and dust
counts taken by the lmpinger technique, it would be neceesary to consider
the effect of background dust, which could be as high as 1 mppcf.
A number of methods for measurement of asbestos dust concentrations
have been used in the NIOSH epidemiological study of the asbestos product industry.13t7bt75,76 Based on these data, the preferred index of asbestos
exposure is the concentration of fibers longer than 5 jim counted on membrane filters at 430X with phase contrast illumination. 71 * 72 This
index is utilized in the method adopted as the standard field sampling
method by the Public Health Service.
'
f.
TX GARRETT
VIII-1
004250
RMC0000081
fibers longer than 5 jim In length are counted in preference to counting
all fibers seen in order to minimize observer/microscope resolving power
variability. Furthermore, the British define a "fibre" as a particle,
"sf length between 5 pm and 100 pm and having a length-to-breadth ratio
oi et least 3:1, observed by transmitted light by means of a microscope
62 aK * magnification of approximately 500X."
i
Although the British have refrained from standardizing on a single
neeciOd of measurement, recent measurements have been performed by a
method essentially Identical to the fiber-count method described in
detail below, and the British hygiene standards for use with their 62
asbestos regulations are stated in these terms.
Prici-iples of Sampling
A dust sampling procedure wst be designed so that samples of
actual dust concentrations are collected accurately and consistently.
The results of the analysis of these samples will reflect, realistically ,
the e.-xmcentrations of dust at the place and time of sampling.
In order to collect a sample representative of airborne dust, which
in ILnely to enter the subject's respiratory system, it is necessary to
jonlei-on a collection apparatus near the nose and mouth of the subject ,r tn his "breathing zone"*
TTne concentration of dust in the air to which a worker is exposed
Ml '/-cry, depending upon the nature of the operation and upon the
. ;>e <uf work performed by the operator and the position of the operator
Inci'.ve to the source of the dust. The amount of dust inhaled by l
0
r'-.iir can vary dally, seasonally, and with the weather. In order to
/
representative samples of workers' exposures, it is necessary
;o*.l.sct samples under varying conditions of weather, on different
VIII-2
D04251
TX GARRETT
days, and at different times during a shift.
The percentage of working time spent on different tasks will affect
the concentration of dust the worker inhales since the different tasks
usually result in exposure to different concentrations. The percentage
can be determined from work schedules and by observation of work routines.
The daily average weighted exposure can be determined by using the
following formula:
(Hours X cone, task A) + (Hours X cone, task B) 4- etc. 8 Hours (or actual hours worked)
The concentration of any air contaminant resulting from an Industrial
operation also varies with time. Therefore, a longer sampling time will
better approximate the actual average.
'
- With the following recommended sampling procedure, it is possible to
collect samples at the workers' breathing zones for periods from A to 8
hours, thus permitting the evaluation of average exposures for a half or
full 8-hour shift--a desirable and recommended procedure. Furthermore,
dust exposures of a more normal work pattern result from the use of
personal samplers. In evaluating daily exposures, samples should be
collected as near as possible to workers' breathing zones.
Collecting Sample
The method recommended in this report for taking samples and counting
fibers is based on a modification of the membrane filter method described
by Edwards and Lynch.
TX GARRETT
VIII-3
f.
004252
RMC0000083
The sample should be collected on a 37-millimeter Mlllipore type AA*
filter mounted in en open-face filter holder. The holder should be
fastened to the worker's lapel and air drawn through the filter by
means of a battery-powered personal sampler pump similar to those
approved by NIOSH under the provisions of 30 CFR 74, The filters are
contained in plastic filter holders and are supported on pads which '
also aid in controlling the distribution of air through the filter.
To yield a more uniform sample deposit, the filter-holder face-caps
should be removed. Sampling flow rates from 1.0 liter per minute (1pm)
up to the maximum flow rate of the personal sampler pump (usually not
over 2.S 1pm) and sampling time from IS minutes to eight hours are
acceptable provided the following restraints are considered: * (a) In order to obtain en accurate estimate of the number of
fibers the statistical error resulting from the random
distribution of the fibers must be kept to an acceptably
low level. Since fiber counts follow a Poisson distribu
tion, a count of 100 fibers in a sample would have a
standard deviation of TUU or 10 fibers or + 10Z. Thus
the 95% confidence limits would be approximately 2 standard
deviations or + 20Z. Since the 37 mm filter has an effec
tive collecting area of 855 smr and the projected field 2 ~
area of the Porton reticle is 0.005 mm , each field rep
resent:: 1/171000 of the sample. Based on this ratio the
following number of fields must be counted to measure the
--
-- ................
'*
varlouc limits in various sampling times:
001253
Mention of commercial products does not constitute endorsement by the Public Health Service or U. S. Department of Health, Education and Welfare.
RMC0000084
Sampling Time Minutes
10 15 30 90 90 240 240 480
Plow Rate 1pm
2 2 2 1 2 1 2 1
Number of Fielda for 100 Pibera 0.2 fibers/ml 2.0 fiberB/ml 10 fibera/ml
4350 2860 1430 1000
500 260 180 180
435 286
143 100
50 26 18 18
91 58
29 20 10
7
4 4 '.
Do not count a field containing over 20 fibers because In addition to the fibers being counted, there are also present a number of grains, which interfere with the accuracy of the count.
Based on these restraints, l.e., number of fields to be counted and maximum number of fibers per field, acceptable sampling parameters for the various limits are underlined in the above table.
The following conclusions may be drawn from this analyBlo:
(1) The short-term limit should be for a period of at
least 15 minutes and preferably 30 minutes.
(2) The 2.0 fiber/cc limit may be evaluated over
periods of from 90 to 480 minutes.
%L $Aa many fields as required to yield at least 100 fibers should '?fr
be counted. In general the minimum number of fields should be 20 and
the maximum 100.
Mounting Somnle
>
The mounting medium used in this method is prepared by dissolving
0.05 g of membrane filter per ml of 1:1 solution of dimethyl phthalatc
TX GARRETT
VIII-5
004254
RMC0000085
and diethyl oxalate. The index of refraction of the medium thus prepared ia ND - 1.47.
To prepare a sample for microscopic examination, a drop of the
mounting medium is placed on a freshly cleaned, standard (25 mm X'75 mm),
microscopic slide. A wedge-shaped piece with arc length of about Its is
excised from the filter with a scalpel and forceps and placed dust-slde-up
on the drop of mounting solution. A No. 1-1/2 coversllp, carefully cleaned
with lens tissue, is placed over the filter wedge. Slight pressure on
the coverslip achieves contact between it and the mounting medium. The
sample may be examined as soon as the mount is transparent. The optical
homogeneity of the resulting mount is nearly perfect, with only a slight
background granularity under phase contrast, which disappears within
one day. The sample should b' counted withlu two days after mounting. Evaluation
The filter samples mounted in the manner previously described are
evaluated in terms of the concentration of asbestos fibers greater
than 5 }im in length. A microscope equipped with phase-contrast optics
and a 4-mm "high-dry" achromatic objective is suitable for this deter
mination. 10X eyepieces, one of which contains a Porton or other suitable reticle at the level of the field-limiting diaphragm, should
be used. The left half of the Porton reticle field serves to define
the counting area of the field. Twenty fields located at random on the
sample are counted and total asbestos fibers longer than 5 jim are__
recorded. Any particle having an aspect ratio of three or greater is
considered a fiber.
,
VI11-6
a
OMlSb
TX GARRETT
RMC0000086
The following formulae are U9ed to determine the number of fibers/ml:
(1) Filter area (mm2) Field area (mm2)
-K
(2) Average net count X K fibers/ml Air volume sampled (ml)
For example, assume the following: area of the filter used was 855 mm t counting area of one field under the Porton reticle was 0.005 mnr
average net count per field of 20 fields was 10 fibers; and sample was
collected at 2 liters per minute for 90 minutes: Then:
855mm2 * 171,000 (K) 0.005 mm2
10 fibers x 171.000 - 9.5 fibers/ml 2,000 ml/raln x 90 min
Calibration of Personal Sampler
The accuracy of an analysis can L-. :.o greeter than the accuracy of the
volume of air which is measured. Therefore, the accurate calibration of
a sampling device is essential to the correct Interpretation of an instru
ment's indication. The frequency of calibration is somewhat dependent on
the use, care, and handling to which the pump is subjected. Pumps should
be calibrated if they have been subjected to misuse or if they have just
been repaired or received from a manufacturer. If hard usage is given
the instrument, more frequent calibration may be necessary.
Ordinarily, pumps should be calibrated in the laboratory both before
they are used in the field and after they have been used to collect a
large number of field samples. The accuracy of calibration is dependent
on the type of instrument used as a reference. The choice of calibra-
tion instrument will depend largely upon where the calibration is to be
performed. For laboratory testing, a 1-litar burette or wet-test meter
should be used. In the field, a rotameter is the most convenient
VIII-7
004256
Instrument used. The actual set-up will be the same for all of these Instruments. The calibration instrument will be connected in sequence to the filter unit which will be followed by the personal sampler pump. In this way, the calibration Instrument will be at atmospheric pressure. Connections between units can be made using the same type of tubing used In the personal sampling unit. Each pump must be calibrated separately for each type of filter used, if, for example, it has been decided to use a filter with a different pore size. The burette should be set up so that the flow is toward the narrow end of the unit.
Care must be exercised in the assembly procedure to insure adequate seals at the joints and that the length of connecting tubing be kept at a minimum. Calibration should be done under the same conditions of pressure, temperature and density as will be*encountered. The rotameter should be used only in the field aa a check if the diaphragm or piston pumps are not equipped with pulsation dampeners. The pulsating flow resulting from these type pumps causes the rotameter to give results which are not aa accurate as that obtained with a burette or wet-test meter. Calibration can be accomplished with any of the other standard calibrating instruments, such as spirometer, Marriott's bottle, or drygas meter. The burette and wet-test meter were selected because of theit accuracy, availability, and case of operation.
VII1-8
t
004251
1 \
TX GARRETT
RMC0000088
2/3 used ir. cement products
tire-oroop textiles, brake linings and gaskets
asacstos paper and mullborad, roof tiling, asbestos sheeting
paint-i, floor tiles, plastics -PRODUCT
CHEMICAL MAI IE
1
fil'-oro in uhen; food, drug, beer industries TRADE NAME, SYNONYMS
Asbestos
90% of asbestos held is of chrysatile variety
CHEMICAL FAMILY
MANUFACTURER
FORMULA Magnesium Calcium Silicate
STRUCTURAL FORMULA
MOL. WT
HAZARD CLASSIFICATION
( > EXPLOSIVE ( ) POISON ( ) CORROSIVE
( . ) FLMrVDLE LIQUID
( ) C-JCSUSTILLL LIQUID
( ) irritant ( ) Oxidizing agent < ) _____
TOxlCITY RATING '
SKIM
GI LUNG
0 * -Tone Acute Local
1 = Slight Chronic Local
2 " Moderate
3 = High Acute Systemic
C Unknown Chronic Systemic f 42 cases of mesotheliomas (rare cancer of pleura and petitoneum) one syr. period, all but 11
ad some exposure to asbestos (10 worked in asbestos plant, 8 lived or worked close to asbestos l&nt, 3 were family members of asbestos workers, 10 had history of assented exposure, 10 no nown history of exposure) (5)Long-continued inhalation asbestosis (intestinal polmonary fibrosis) isease is characterized by asbestos bodies in lungs and sputum. Based on x-rays can be inssified as minimal, moderate and advanced. It is a serious disease in some nisfones but
usually just disubliny unless some other serious disease sequences (5) Chief synptons f advanced asbestosis are variable cough, dysynea, substernal chest pains, cher. chest expansion,
etnass, emaciation, clubbed fingertips and curved fingernails. Any appreciable dec. in ain't
f jsbestoa lust in breathing atraos. will cause dec. in incidence and severity of asbestosis. ndi-'iduai susceptibility varies (7, Hyg. Guide)
Neoplasms, such as pleural and paritioned mesothelioma, occur in excess uven among aabestoc
crkr-cs with little nir.o radiological evidence of asbestosis, suggesting that exposures insuf-
tuaecic -o causa asbestosis may still produce neoplasia. (22,23)
004258
TX GARRETT
RMC0000089
.':TiSICr- re CHEMICAL PR.OPER.TIES See Mineralogical Appendix of (36).
Physical State-Masses, either compact or of long silky fibers, flax-like and readily separa Color white, greyish or greenish Cdor Vapor Density (air = 1) Vapor Pressure (arc Hg) Specific Gravity (^O = 1) halting Point Soiling Point
Hash Point Auto - ignition temp.
Vicsocity Surface Tension Evaporation Rate lei uel
Pa pka
Partition Coefficient Solubility Coefficient
Solubility - II..0
lipids
Stability
Che can Reactivity chem. inert and resists attach by most chem.
Decomposition & Polymerization Products
Materials 1 Conditions to Avoid
TX GARRETT
004259
RMC0000090
Ingredients (if mixture or contains sig impurities)
TLV
"nrysotile (hydrated nagnesium silicata) from serpentina = 95" of commercial asbestos
:rocicolits (sodium iron silicate) ir.osile (iron magnesium silicate) '.remolita (0-20 mole " of (OH) 7Ca?Fe^Sig022) inchophyllite iccinifs
FIRS & EXPLOSION HAZARD
Fire - fighting Procedures
Personnel Protection (Clothing, equipment, ventilation)
Storage & Handling
Clean - up and Disposal
liZALTH HAZARDS
LD._ (lethal dose 50)
LD (annrox. lethal dose) ca
LC^q (lethal cone. 50)
LCca (aoprox. lethal cone.) TJ2 (toxic dose)
TXC (toxic cone.)
TF.: (toxic effects)
TLV ppm
Sampling period
Biol.
(1/10 t/12)
half-time
Ref.
:.c 5 f i.ber3/ml (longer than 5 ) 5MPPCF
eg this is too high (See TLV documentation and 17)
(12,11) (1
(13,14,15,
TX GARRETT
004260
RMC0000091
riterui for limiting shrysociio exposure assuming if; of asbestos during 50 yr. working exposure.
use category
oglibibi:
suium
Chrysotila Cone. (av. of 3 hrs) fivers in iengc m
0.5
0.5-2.0 Unit of 100 fibers/ml yrs 2-10
10
5 mppcf would provide inadequate protection 2 night not be substantiated
/pus of Asbestos (21) hrysotila - widely used in food processing industries (sugar, lard, beer), re bundles of fibrils, each 2GQ-400A dia and 1000 A to several micrometers long narmnceutical use a3 filter rocidoiite - gas mask and cigarett filters nosite rithophyLlite remolite aount of asbestos in some samples of dwgs exceeded chose ir. other env. circumstances .uch as in (21)) These were drugs to be given on IV, IM in IP.
jurces of Asbestoc incl. serpentine rock (chrysotile).. Industrial controls are necessary 3 provent air pollution, particularly in construction products, ship building and repair.(22)
lrysotile :curs Lr. icpenrinc rock
rocidoiite rears in banded ran stone rosit -
Prod. (1962) 1000 tons 1700
132
75
Color white
blue brown
Composition (%) Si Me Fe 40 38 2
50 ---- 40
50 -- 40
Source
Canada, S. Africa, S. Rhodesia, U.S.A Italy, Cyprus
S. Africa (Cape) Australia
S. Africa (Transuaal
lthophyiiits
11
white
58 29 6
Finland, Italy
TX GARRETT
004261
RMC0000092
Breath TLV
Absorption Fata
Execretory Rate Am't of asbestos recovered from lungs of persons occupationally exposed as ranged from 0.6-0.001% of lung wt. (24) , with chrsotile asbestos fiber lew and anphibole sbastos fiber generally high (25)
Critical Site (Locus of Action)
ahalation, Alreolar membrane responds with production of chronim interstitial pnemonitis (35)
ce aisc 24) Biotransformation Chrysotile asbestos tends to break down chem. and physically after pro-
enged bid. residence. Is chen. unstable every in distilled H2O, and ag. sclu < 0.3 pH. Some f its aagnesiun will be leached out (24,25,26). The bundle of fibrils breaks open and the nuiviunal unit fibrils are separated (27) (Not seen with aaphibote asbestos) (often <0.5u)
Susceptible Individuals
Cone. X Time
itural chrysotila .05-0.2y-10.5 mg + 14 mg .2-1 pula.
Response or Effect
90% mortalilz in 18 nos. 100% mortalilz in 24 mos.
Species 55 rals.
P.ef. 3
/nthetic chrysotile firbrous also macrophage reaction with ninlmal stromal participation did
at collagenize
.02-0.04 u dia. 14 mg + 45 mg. 22% mortalilz in 12 mos.
3
53% mortalilz in 24 mos.
sic (trumolice
.1-0.2 u dia 25 mg to 50 rats injected intratracheally 40% mortality in 6 mos
0.2 ji = high natural nickel content
44% mortality in 6 nos
0.1 y * Low natural nickel content
3
Lsc. polypoid proh teratiose infiammuration which in time become callogenous scaes deforming
ir ways amorphous magnesium silicate 75 mg intratrachally in 10 rats 10% mortality in o mos. 3 roliferative inflammacion considered artificial
TX GARRETT
004262
RMC0000093
ST SPTOMS
Acute
Chronic Mesothelioma of the pleura occurred in 33 cases in S. Africa, all but one with a :robabl2 exposure to crocidolite asbestos (ape Blue) (32) Pleural calcification from asbestos :xposure may occur. Appears usually bilaterally in pauetal pleura (x-ray) vith no clinical objective or subjective resp. symptons. (36)
Diagnostic Procedures ^ characteristic finding in asbestosis is asbestos bodies in lung md sputum. The care of the body of an asbestos fiber is surrounded by protein deposits; un stained specimens are golden yellow or golden brovn. They (in lung or sputum) are not stained by ordinary histological stories but may be demonstrated by Prussion blue staining pro:edure (S). See also (9). After death when lungs examined by naked eye they are large and leasely fibrotic. Often the lung is completely adherent to chest wall and in advanced cases to iiaphrogan with formation of a thick and extremely dense layer of fibrous tissue. 4 main compil ations and segutae of polmonary asbestosis are purulent bronchitis, bronchial pneumonia, pulmona
TB and emphysema (8) Treatment
'.emoval from exposure.
Medical Surveillance
'eriodic clinical exams for signs and symptons of asbestosis, mil-examination of sputum or asbestos bodies and chest x-rays (hyg. Guide) In general the lapsed period between onset f asbestos air pollution and appearance of neoplasia is 20,30, 40, or more yrs (22). Possible ariable parameters mid-intensity of exposure, fiber variety, size, competitive risk of asbestos, ofaccors such as cigarette smoking, trace elements . . . (22) atent period rarely less than 10-20 yrs (30).
TX GARRETT
004263
RMC0000094
INDUSTRIAL HYGIE:iE
Detection of Odor
Environmental Concentrations (including by-products)
Operations Being Used
Plants Being Used: Potential Hazard
O.K. if
Range of Cone. Average Cone. + ->J n-i
TLV
Analytical Procedures
. Qual. Analysis of Ilinerals by Solid Infrared Spectroscopy for mineral identification suppleents used instead of X-ray diffraction. Qualitative infrared spectra for amouite, crocidoite, tremolite, serpentine, chrysotile. (4) Procedure for X-ray diffraction So chrysotile, rocidoiite and axaosite and applicable to quantitative determination in 1-8 mg range latte
and 1-10 mg range for chrysohS (37) (39,40) . Dust nay be sampled with electrostatic precipitation or by impinges method using alcohol or Icohol and water as collecting medium (1,3) The index of refraction of chrysolite is only lightly greater than Canada balsam, so relief is low. Other forms of asbestos have higher r.dices of refraction. Extinction is parallel except in case of tremolite which has oblique xtir.ction. Bizefungence of chrysotile is moderate nv - na = 0.03. Max interferences color s yellow of the 1st order. (8, see 10). TLV is bored on impinger sampling procedure.
Environmental Monitoring TLV is based on fiber count, but LM observations that would be aunted as; a article, by the EM is seen as numerous fibers (fibrils) attached to the surface f particles. In such circumstances any biol. effect of the fibers could be incorrectly atributad to particles (22). Each asbestos fiber variety is quite different. Chrysotile iber zor ex. is not a unit whole but is composed of a number of 300-400 A fibrils. In ndustrial situations one has soma idea of the ratio of optically visible fibers/total chrysotile on. Mot so in ambient air. Probably region EH to get this ratio and then use dp M in ccupatirnal setting. Ambient air reguines EH with magnification of at least 20,000 and probably ver 4C,o00 x (22) %'hat i3 seen by light microscopic methods often differs from EM observations or 1/100 fibers present in air could be seen with III as compared to EM) and chat rasp, size frac ions need not have 3oae size and 1st or properties as those in gross overall sample (24, 23)
004264
TX GARRETT
RMC0000095
M it
ric method u3ins Kariet sampler (31) ectronic Counter - continous series of dust cannot of predetermined si2a (31)
*
V.
TX GARRETT
004265
RMC0000096
Analytical Methods
(38) reports a procedure for separating respirable dust fraction (< 10y) from settled dust, dust collected with hi-vol and electrostatic precipitatas sam plers. The chera. and physical natures of the respirable fraction can then be analyzed. This method has been applied to asbestos and has shorn that the chemical composition of the fraction < 10|J may be quite different from the parent material.
The results of our surveys of 9 asbestos textile plants reveal that dust cone, as measured by impinger are generally below TLV. Estimates of relative dusti ness from membrane filter samples were in good agreement with those made from impinger samples by either cone, or body burden methods of graying. Both show approx, some variance, A gross airborne mass cone, of asbestos equiva lent to 5 mppet would be on the order of 1 rag/m^, and respirable mass cone, as determined by elutriator and cyclone, would be in the order of 0.5-0.6 mg/m3 and 0.3-0.4 n:g/nJ respectively. The impinger is as convenient as any other method of sampling and no less accurate. However the hygiene criteria is based on largely grain counts while the fibers are thought to be the cause of disease. For this reason the counting of fibers on membrane filters appears to have an advantage, esp. in industries where asbestos is only a small fraction of the aribaine dust. (41)
Sampling
The impinger method is not adequate for obtaining a statistically useful in dex of auharne fiber cone, i.e., that part which is most relevant to dis ease-causing mechanism. The impinger has a collection eff. related to aerodynomic size of particles and is not efficient for particles with falling speeds < 1 y unit density spheres. Further the lOx objective, light field, counting technique used does not resolve particles much smaller than 1 y. It is est. that M./100 fibers in the air as seen in EM was seen in im pinger samples. Impinger counts are based to large extent on grain counts. Cut the falling speed of fibers dependent on dia only when aspect ratios 710; It is possible for much larger and heavier objects to penetrate deep into the lung if shaped as fibers than in the shape of grains.
Using membrane filters pare sizes of 0.8 y/ almost 100SE efficiency is ob tained for fibers down to several hundreds of a micron. The fibers are rendered transparent witn 1:1 dipthyloxalate and dimethylphthlate I counted with 4 mm objective (430x) under phase contract illumination.
(Then impinger samples give cone, of a 5 mppcf, membrane filters cone, are
as follows: total fibers = 50 fibers/cc.
fibers longer than 5 y = 30 "
"
fibers longer than 10 y =15 "
"
A goal of 4 fibers longer than 5 y/cc has been mentioned for English asbestos textile mills, approx, equivalent to 1 mppcf by impinger count
TX GARRETT
004266
RMC0000097
which is vary near the Tower practical Unit of sensitivity for the impinger. Wt. method of analysis suffers fron soma dafect as impir.gar.
Chrysotile asbastos fibers are commonly found in lungs of urban dwellers with no occupational exposure to asbestos (22). Asbestotic pleural calcifiacion has bean associated with use of rock with high asbestos (anthcphyllite) con tent in various parts of world (Bulguin, Finland, Czechoslavakia?) Ref. 1522.
Recovery of chrysotile asbestos from lung tissue always low; recovery of amphibole asbestos generally high in human lungs (25).
Asbestos insulation workers have comparatively light asbestos exposures as asbestos trades go. Many of the material they use contain little or no as bestos and others 5-15%. What few dues exposure surveys have been done have generally been within the 5 rappcf TLV. When exposure is reduced, eearly death from ashestosis decreases, and lung cancer becomes more common. Light exposure may come from industrial exposure and/or community asbestos air pollution. In this study it was shown that there is an extraordinary risk of developing and dying from lung cancer for asbestos workers who smoke cigarettes regularly. In the group studied, the combination of asbestos ex posure and cigarette smoking a. 90x compared with men who neither work with asbestos nor smoke.(29).