208 -CHAPTER 9 > fT9S8! Guide Table 16. Determination of U Value Resulting fbom Addition of Insulation to Uninsulated-Building. Sections (Concluded) " (For use with Tables ISA arid 1SB). PART E. FLAT ROOFS AND CEILINGS WITH ROOF DECK - ; .: U Value os* Roof. without Roof-Deck Insulation . ` 0.12 V: CConductance of Roof-Deck Insulation 0.15 0.19 0.24 0.36 ;u u V V . 0.72 .u A A -> 5VJ. s 0.10 0.15 0.20 0.25 0.30 -0.05 0.07 0.08 0.08 .0.09 ' 0.06 0.08 0.09 6:69." 0.10 0.35 0.09 0.40 ; 0.09 0.50 . , -0.10 0.60 -0.10 0.70 0.10 0.10 -.0.11 0.i2 . 0.12 0.12 0.07 0.08 0.10 0.11 0.12 0.12 0.13 0.14 - 0.14 0.15 0.07 0.09 0.11 0.12 0.13 0.14 0.15 0:16 0.17 0.18 6.08 0.11 0.13 0.15 0.16 0.09 0.12 J 0.16 a 0.19 * .0.21 a; 0.18 0.19 . 0.21: -' 0.22 . 0.24 : 0.24 ir 0.26 ;v: 0.29 5; 0.33 0.35 ii a Interpolation or mild extrapolation may. be used. ' ' ' ; .. & Example 4- Consider the' floor-ceiling construction shown in the example at the; top of Table 11, insulated with a sheet of aluminum foil, or paper faced on both sides -,: with foil, (effective emissivity (E) of airspace = 0.05) placed between the joists ahjL; dividing the air space intoTwo.lequal spaces. From Table 11, the U value for die';, uninsulated construction is 0.18 for heat flow down for summer, and 0.23 for hc&V - flow up for winter. Determine the coefficient Ui for: ~ ; &;- (a) Heat flowing downward from uncooled room above to cooled space below/(a`. summer condition) and, '' - (b) Heat flowing upward from heatedr room below to unheated space above/ja, winter condition). J o'O Solution: -' (a) Use Table-16 Part D, and corresponding to V = 0.18 in Column 1 find/iS: -Column 11, Ur= 0.049. Use 0.05. r; (b) Use Table'16 Part C, and corresponding to U = 0.23 in Column 1 find,jin;'. Column 11, U-, = 0.124, (by interpolation). Use 0.12. it'1 Special Uses of Table 16 : Jjf' Values of Ui for insulating applications or combinations other than thog` indicated by the headings of Columns 2 to 14 of Table 16 can be ascertained!^ if the table is used -appropriately. For instance, going horizontally in tfjftxtable from Column 2 to Column 3 is equivalent to adding in. of fibi.buj> insulation to the construction. Similarly, going from Column 2 to ColuntfUl .4 adds \)/2 in. of fibrous insulation to the construction. In the same way going horizontally from Column 8 to Column 11 is equivalent to adding.tfl; a construction the insulating value of one additional highly reflective.; (E = 0.05) air space, and going from Column 6 to Column 12 in effect ; adds two non-reflective (E = 0:82) air spaces to the construction, etc. Examples 5 and 6 show the combinational use of Table 16. tir Example S: Determine the coefficient U\ for the wall of Example S, with of fibrous insulation added on one side of the air space. '$ Solution: Ui can be .determined in several ways, by using Table 16 Part A,-f example: :' -' (a) By going from Column 1 to Column 2 three times, for a total ofl)4 inches.11 insulation, as follows: enter Column 1 at 0.24 and find Ui = 0.166 in Column 2; en Heat Transmission Coefficients of Building'Materials 209. Column 1 at 0.166 and find Ui = 0.126 in Column 2; enter Column 1 at 0.126 and find Ui = 0.102 in Column 2. Therefore, for a total of 1)4 in. of insulation, use 0.10. (b) Move simply, by going from 0.24 in Column 2 to 0.103 in Column 4. Use 0.10. Example 6: Considering again the wall hi Example S, assume that'one-inch blanket insulation is to be installed in mid-space, leaving equal air spaces on. the two,sides. The coefficient Ui is desired for two cases in winch, , , , ,, _ (a) the blanket has non-reflective surfaces.on both sides, so that both air spaces are non-reflective (E = 0.82) and, (b) the blanket has one highly reflective surface, so that one of the air spaces is highly reflective (E = 0.05). . ' _j ) Solution: (a) In Table 16 Part A, when U without added insulation is 0.24, Ui for one inch' of fibrous insulation and one non-reflective air space, is 0.127 in Column 3. To add the second non-reflective air space, enter Column 6 at 0.127, and by interpolating find Ui = 0.112 in Column 9. Use 0.11. (b) Ui for one inch of fibrous insulation and one.non-reflective air space is 0.127 as in (a). To add one E = 0.05 air space, enter Column 8 at 0.127 and by.ihtefpo-. lating find Ui = 0.092 in Column 11. Use 0.09. 1 ,, . u/ul Fig. 6. Correction for Effect of Framing in Insulated Building Sections U*.r = average V value for building section. . .. Ui = U value for area between framing members. Ua = U value for area backed by framing members. S - Percentage of area backed by framing members. ^ r./, -. CORRECTION FOR FRAMING Correction for parallel beat flow through framing and-, insulated Areas may be made by use of Fig. 6. Correction for the effect of framing should be applied after final Ui and U,, values have been obtained for a given con struction. In many cases this correction may be omitted. Example 7: Consider a frame wall with 2-in. blanket insulation winch has a Ui value of 0.08. By calculation it is found that heat loss from the area backed by fram ing members (U.) is 0.13. UJUx is 1.63. From Fig. 6 if 15 percent oh wall area is backed by framing, the value71/,,/fA = 1-1. U,, is therefore 1.1 X 0,08: = 0.088. Combined Ceiling and Roof Coefficients If the attic space between the ceiling and roof is unheated and not venti lated, the combined coefficient from room air below the ceiling to exterior can be calculated from the following formula: .... Rr~VU^,, '+nnUU,, The combined coefficient U is the reciprocal of Rt, or (4).