.........................has been used successfully since 1941 as a liquid phase heat transfer medium at atmospheric pressure and temperatures up to 600F.
The compound, essentially tetrachlorobiphenyl, is a fire-resistant and non corrosive liquid, which does not crystallize at low temperatures. Handled properly, in well-designed forced circulation heat exchangers which avoid localized overheating damage, the fluid gives satisfactory continuous service for many years without replacement.
Most significant, Aroclor 1248 is practically non-flammable. In one in stallation of record, a ruptured pipe spewed the hot fluid into gas flames: the fluid failed to ignite!
For general heat transfer, Aroclor 1248 has several other important qualities: it is highly mobile and can be readily pumped at temperatures as low as 50F. If cooling is necessary, the heat transfer fluid can be put through a water cooler and used as a coolant.
Aroclor 1248 transfers heat (up to 600F.) as a liquid. This liquid phase heat transfer makes it unnecessary to use the expensive pressurized equipment required by a heat transfer medium that operates as a vapor. Aroclor 1248 operates safely and efficiently with gas-fired, oil-fired, or electrical heat sources. It is used successfully in the following types of applications ....
L VV6T00
Chemical processing equipment, particularly for reacting flammable materials
Cooking of alkyd resins, varnishes, waxes
Plastics molding, extruding, calendering
Rubber processing
Heatingasphalt
Food processing, including potato chip and doughnut frying in vegetable oils
Processing titanium, magnesium, other non-ferrous metals
i
i Fabrication of magnesium and aluminum honey-comb structures for aircraft i
Indirect heating in dyestuff manufacture i
Heatingof corrugating rolls
Indirect heating of distillation equipment
Saponification of fats
Calcining ovens
Impregnation and lamination of fibrous materials
j 2\
U.JPfU! AJIP'WIW1
f
TOWOLDMONOQ20549
BVV6T00
TABLE I
Appearance Absolute density, g./ml.
Absolute viscosity, centipoises
Thermal Conductivity, Btu./hr./sq. ft./F./ft.
Spec. Volume, ml./g.
Practically colorless mobile liquid.
Temperature "Centigrade "Fahrenheit 1.44 30 86 1.41 60 140 1.37 100 212 1.27 200 392 1.17 300 572
112.0 30 86 17.5 60 140 4.2 100 212 0.99 200 392 0.47 300 572
0.0571
30
0.0564
60
0.0555
100
0.0534*
200
0.0512*
300
'Extrapolated Data
86 140 212 392 572
0.696 0.709 . 0.728 0.787 0.860
30 60 100 200 300
86 140 212 392 572
CONTINUED
3
TOWOLDMON0020550
(Table 1, emit.)
Spec. Heat, cal./g./C.
Vapor Pressure, mm. Hg.
Distillation Range, ASTM D-20 Flash Pt., Cleveland Open Cup,
ASTM D 92-45 Fire Pt., Cleveland Open Cup,
ASTM, D 92-45 Pour Pt., ASTM, D-97 Average Coefficient of Expansion
cc./cc./F.
0.283 0.297 0.326 0.355
0.00037 0.16 2.9 18.0 350.0
"Centigrade 50 100 200
300
"Fahrenheit 122 212 392 572
37.8 100 100 212 150 302 200 392 300 572
345-385
652-725
193-196
379-384
None
0.00037 0.00038 0.00041 0.00044 0.00047 0.00052
--
-7
-17.8 to 37.8 37.8 to 93.3 93.3 to 149 149 to 204 204 to 260 260 to 316
--
19.4
0 to 100 100 to 200 200 to 300 300 to 400 400 to 500 500 to 600
PHYSICAL CHARACTERISTICS
of AROCLOR 1248
A complete knowledge of the physical characteristics of heat transfer media is highly essential to their satisfactory application in a heat excluingcr. These physical constants have a major hearing on the equipment design, its maintcnance, and its operation. The following figures and charts give basic physical data on Aroclor 1248.
TOWOLDMONOQ20551
0019449
DENSITY OF AROCLOR 1248
(Top axis, Ibs./cu. ft.; bottom axis, gm./ml.) DENSITY Ibs./cu. ft.
TEMPERATURE F.
t e m p e r a t u r e *f.
i'I,.
iuwu,m u j Min i iHi.a,jLqij iai
TOWOLDMONOQ20552
TEMPERATURE eF.
0019451
VISCOSITY OF AROCLOR 124S Figure 2
VISCOSITY OF AROCLOR 1248
(Saybolt Universal Seconds)
VISCOSITY, SAYBO IT UNIVERSAL SECONDS
Figure 3
k umimm****!*?
TEMPERATURE, DEGREES FAHRENHEIT
7
TOWOLDMON0020554
CSVfcT 0 0
HEAT CAPACITY and Its Relationship to Density
Systematic errors exist in the various accepted pro cedures for making specific heat determinations. Consequently values may vary depending upon the procedure used. In practical operation, it frequently appears that the values for Aroclor 1248 shown in Figure 4 are somewhat low. Consequently, although these values have been accurately determined, they may be regarded as conservative.
When comparing the specific heat values of Aroclor 1248 with corresponding values for other heat transfer fluids, it is important to note that the density of Aroclor 1248 is much higher, relatively, than the density of other liquids used for heat transfer. Accord ingly, when comparison of heat capacity is made on a
volume basis (which is most pertinent in equipment design and efficient operation) the heat capacity of Aroclor 124S shows itself to bettor advantage than In direct comparison of sjx'cific heat values.
Although specific heat values are important, they represent only one of several important constants that enter into the equations for calculating over-all heat transfer efficiency.
Through the use of these conservative heat capacity values, it is possible that equipment engi neered from such data might be slightly "over designed." This may be one of the factors that accounts for the exceptionally good operating performance of a number of highly successful commercial applications.
SPECIFIC HEAT OF AROCLOR 1248
(Btu. per lb. per degree F.)
O
TEMPERATURE F.
Figure 4
SPECIFIC HEAT Btu./I6./F.
1^
J x 1,1a*. ? in i..W uiiJ !U P|OTPIHPil
TOWOLDMONOQ20556
0019A55
Temperature
c. F.
0 32 10 50 38 100 66 150 93 200 121 250 149 300 177 350 204 400 232 450 260 500 288 550 316 600
TABLE II HEAT CONTENT
of Aroclor 1248
Specific Heat Btu./lb./F.
.269 .272 .280 .288 .295 .303 .311 .319 .327 .335 .343 .351 .359
Heat Content Btu./lb.
0.0 4.85 18.65 32.85 47.43 62.38 77.58 93.48 109.66 126.21 143.17 160.52 178.27
10
TOWOLDMONOQ20557
0019^56
t THERMAL CONDUCTIVITY !
and VISCOSITY t
j
ti
The thermal conductivity values of Aroclor 1248 are
Although Aroclor 1248 tends to darken in use,
ts
i
shown in Figure 5. The curve shows this value over
this darkening is not harmful and does not indicate
A{
the operating temperature range, from 50F. to600F., of Aroclor 1248.
decomposition. In actual use at Monsanto, it has not
As freshly charged into a heat exchanger,
been found necessary to replace the fluid after seven
I
Aroclor 1248 has an initial viscosity of 74 (S.U.S.) at
years of continuous use; additional fluid is only added
f
130F. which corresponds to a viscosity of approxi
as necessary to make up spills or leaks.
f mately 5000 (S.U.S.) at 50F. -- which temperature is
t
assumed for practical purposes to be about the limit at
In Figure 6, the horizontal line indicating vis
I
ii
fi
which Aroclor 1248 can be conveniently pumped with a centrifugal pump.
The following table shows a comparison of the
cosity limit of pumpability at 50F. shows that the rate of viscosity increase based on a year's continuous
initial viscosity and the viscosity after a year's con
service should permit Aroclor 1248 to serve approxi
j
tinuous service at 600F. in a LaMont forced circu
mately four years before increased viscosity may inter
!\
l
lation heater:
TABLE III
fere with its pumpability when cold. In practice,
After one Year
Aroclor 1248 has given satisfactory pumpability for
of service at
Original
60CF.
much longer periods. A simple S.U.S. viscosity deter
Appearance Specific Gravity, 65 G.
Colorless Liquid 1.410
Dark Brown Liquid 1.418
mination by the ASTM-D-88 method can be used for
f
Viscosity, S. U. S. at 130F.
74.0
83.5 periodic checks on the fluid.
\
i
i it - 11
TOWOLDMONOQ20558
THERMAL CONDUCTIVITY OF AROCLOR 1248
(Dotted extension indicates extrapolated data)
0019457
PumpmcPOTP
TOWOLDMONOQ20559
EXPECTED MINIMUM SERVICE LIFE IN A FORCED CIRCULATION HEATER
Figure 6
VISCOSITY, SAYBOLT SECONDS, al 130"F.
140 130 120 no 100 90 80 70
13
0019459
STABILITY
j
Aroclor 1248 is an extremely stable chemical com pound. Tests over long periods of time have shown that 600F. is a safe maximum temperature for continuous operation in heaters that are properly designed and operated to eliminate intense, localized overheating. At this temperature the fluid is 52F. below the initial temperature of its boiling range, and consequently re mains a liquid.
Near its boiling point Aroclor 1248 tends to dehydrohalogenate to a very slight but measurable degree. If this occurs as a result of accidental over heating, the small amount of IIC1 gas evolved tends to pass through the vent tank without harm to the equipment provided that the system is dry.
Experimental observations using ideally-suited heat exchangers operating at a temperature of 650F. with imposed nitrogen pressures of 80 and 70 psig. showed that application of pressure did not prevent this small amount of thermal decomposition, which also occurs when the material is heated above 600CF. at atmospheric pressure.
When heated continuously at 650F. under nitrogen pressure a gradual increase in the viscosity of the fluid occurs indicating that its service life would be limited to about 6 months to one year.
Results of operating at 600F., however, with out imposed nitrogen pressure indicate Aroclor 1248 can be heated continuously at this temperature for about 4 years before any viscosity increase could be expected to interfere with its pumpability at 50F. which is slightly below normal room temperatures.
Provision should be made to prevent water contamination of the system. If the system becomes contaminated with water, any HC1 liberated by local ized overheating may dissolve in the water film which will float on top of Aroclor 1248 in the expansion tank. The acidic solution thus formed can cause corrosion. It is recommended that moisture be eliminated from the expansion tank by installing a moisture trap or by sealing the tank and applying 15 to 30 psig. of nitrogen gas. With exception of the expansion tank, the system should be kept full of Aroclor 1248 at all times to pre vent formation of air pockets where moisture may condense when the system cools off between periods of operation.
Many years of practical operating experience have shown that Aroclor 1248 is virtually non-corrosive to valves, piping, tanks, and jackets made of cast steel, steel, or stainless steel. In actual use, brass valves have been used satisfactorily.
SAFETY of OPERATION
Aroclor 1248 can be considered a non-flammable liquid; no fire point is obtained by the Cleveland Open Cup method on heating to its boiling point (650F.). The spontaneous ignition temperature(2) is 1,299F.
In actual use, the following reported accident in a heating system demonstrates the fire resistance of Aroclor 1248 and the freedom it offers from the hazard of fire propagation. An operator's failure to start the circulation pump when the gas heater was on resulted in excessive coil temperatures. The line containing Aroclor 1248 sagged into the fire chamber. A weld rup tured and Aroclor 1248 poured into the red-hot fire chamber in contact with the flame. Dense smoke and fumes arose from the heater but there was no external fire. After the gas flame was cut off, the smoking stopped.
Insurance authorities allow the use of Aroclor 1248 heaters in many locations with a minimum of protection. No fire walls are required to isolate the heaters.
Aroclor 1248 has a low vapor pressure. In sys tems that employ a vented expansion tank, the loss due to evaporation is not measurable. If Aroclor 1248 in the expansion tank would reach a temperature of
266F., the vapor pressure of the fluid would be only 1 mm. of Hg.
SAFETY OF HANDLING
Aroclor 1248 is an inert, unreactive liquid. If it is spilled on the skin, there are no noticeable ill effects. It is advisable, however, to wash the skin with soap and water after contact.
A skin burn resulting from accidental contact with hot Aroclor 1248 should be treated in the normal manner for hot oil burns. Any liquid adhering to the burned area need not be removed immediately unless treatment of the burn demands it. If the burn must be cleaned, soap and water or repeated washings with a vegetable oil (olive oil) may be used.
The vapors emitted by Aroclor 1248 heated to elevated temperatures are injurious on prolonged ex posure and should not be breathed. It is indicated that 2.0 mg. of Aroclor 1248 per cubic meter of air is the maximum safe amount permissable in workrooms. In commercial heat transfer installations, it is presumed that Aroclor 1248 will be used in a closed system free from leaks. Accordingly, there should be little or no opportunity for workers to come in contact with Aroclor 124S vapors.
A bibliography appears on page 32.
0019^
HEATER
The most significant factor to remember when selecting or de signing a heat exchanger for Aroclor 1248 use is this:
Aroclor 1248 transfers heat while in liquid form, at the maximum recommended temperature of 600F. for continuous operation, which is approximately 50F. below the boiling point. Conse quently, Aroclor 1248 does not form vapor to accelerate convection circulation. Ordinary fire-tube or water-tube heaters which depend solely upon convection perform satisfactorily only at relatively low temperatures.
When temperatures of 500-600F. are required, a forced circu lation type heater is recommended. A satisfactory type of heater design would consist of a specified number of tubes in parallel, properly orificed to provide a high velocity fluid flow of 8 to 10 feet per second. These should be spaced to permit uniform heat absorption throughout their entire length. A typical construction is shown in Figure 7.
In its fabrication, the heater should be ASME Code all-welded construction, conforming to state and local ordinances. Tube joints, which in an ordinary steam heater would be the expanded type, must be sealwelded to prevent leakage. All connections larger than %" should be flanged connections, since ordinary threaded pipe connection is not suited for Aroclor 1248 service. Spiral-wound stainless steel and asbestos com bination is recommended for sealing joints and plugs.
Drain valves should be installed at all low points on the heater and the valves must conform with ASME requirements for "blow down" valves.
TOWOLDMONOQ20563
0019462
MULTIPLE SMALL TUBES
Since a heater operating on Arocior 1248 is completely filled with liquid, costly liquid-level controls and condensate return pipes, fittings, trails, etc. are completely eliminated.
Heaters can be provided with any desired kind of firing. Portable and small size stationary units are frequently elec trically heated; larger units may be gas- or oil-fired. In installa tions where an open flame presents a fire hazard, to meet insurance requirements the heater may be installed in a sepa rate building with piping carrying the hot Arocior 1248 to the point of use. Properly constructed transmission pipes may ex tend for hundreds of feet.
HEATER EFFICIENCY
Forced circulation heaters with integral economizers will show
an efficiency of from 75 to 80%. Heaters of the straight con nector type show efficiencies of 65 to 75%, depending upon the discharge temperatures.
HEATER CAPACITIES
Heaters using Arocior 1248 (gas- or oil-fired) are available in output capacities ranging from approximately 250,000 Btu. per hour to large units rated over 10 million Btu. per hour. A heat flux density (or heat energy input) of approximately 5,000 Btu. per hour per square foot of tube surface is regarded as satisfactory.
For lower output rate, electrically-heated units are favored, employing watt densities of 12 to 16 watts per square inch of element area.
17
TOWOLDMONOQ20564
THE USERS
The "users' or recipients of the heat at the point of processing can be any type of heating pan, platen, jacketed kettle, or coils of steel or stainless steel construction. Ordinary low pressure construction is satisfactory, since the pressure imposed on the Aroclor 12-18 seldom exceeds 30 psig. In the user, however, it is important that all-welded construction be used. Threaded connections tnay allow leakage of the hot fluid. As in the heater, all connections -V' and over should he flanged and all joints sealed with spiral wound stainless steel and asbestos gasket material. Alloy bolts should be used to secure flanges. A typical system with several users is
UPANSIOU vtsstl
FUll EXPANSION IEVEI GAUGE
COIO START
0019*63
Figure 8
15
TOWOLDMONOQ20565
THE PUMP
Fot most systems, cast-steel centrifugal pumps with watercooled stuffing box and bearings are to be preferred. However, high temperature centrifugal pumps with mechanical seals are now available which give excellent performance. In some in stallations, immersion pumps have Ix'cn used. Whatever type is selected, the pump capacity and pressure head must be sufficient to circulate the volume of fluid at the rate the particular installation demands.
To avoid shaft trouble and leakage at the seals, it is important to provide adequate expansion joints and to support the piping in a manner to avoid stresses on the body of the pump. Direct-connection pumps driven by 1,750 rpm. motors are most commonly used. Each pump should be fitted with a positive differential control to switch off the burner in case of pump failure.
When a new system is first put into operation; a slight leakage may be noticed at the pump. It is not advisable to tighten the pump gland, however, until the system has heated up close to the temperature of operation.
PIPING LAYOUT
The most important factors in the piping layout for Aroclor 1248 systems are (a) proper sizing for the required flow rate and (b) minimizing pressure drop. Because the sys tem will undergo temperature changes, adequate expansion joints and loops to relieve expansion and contraction stress are essential.
Preferably, all pipe lines and connections should be of extra heavy or Schedule 80 welded construction meeting A.S.M.E. requirements. However, Schedule 40 welded pipe construction is often employed. Flanged joints should be used as sparingly as possible to minimize potential leak points.
All valves and controls should be cast steel construction with stainless steel seats. Pipe lines should be well insulated and those exjwscd to temperatvires t>elow 70 F. should be steam jacketed.
All high points in the piping system should be provided with vent valves; all low points should have drain connections. Piping should lx? well anchored at frequent intervals, particu larly near expansion loops, to prevent vibrations.
Figure 9 shows a typical piping diagram that illustrates the important features of an Aroclor 1248 piping system. These may be varied to suit the installation.
19
TOWOLDMONOQ20566
0019465
THE EXPANSION TANK
The expansion tank should be large enough to accom modate about 20% of the total volume of the entire system, including the fluid content of the heater, piping, and all heatusers. Tank should be sized to be Vi-fuli when system is cooled to 70CF. and %-full when system is at maximum operating tem perature. Expansion tank should be fitted with a sight glass at the "full" range and a float-operated low-level switch to shut off burner in case of accidental fluid loss in the system.
The expansion tank should be mounted on a platform high enough to support the liquid reservoir at least six feet higher than the highest point in the piping system.
THE FEED and DRAIN PUMP
To eliminate manual filling and draining of the heating system, it is recommended that a small 2-to-5 gpm. positive displacement pump be installed at some convenient point to pump the Aroclor 1248 into or out of the system.
CONTROLS
Controls for heating systems using Aroclor 1248 should be installed both on the heater itself and on the heat-using units. A wide variety of thermo-operating controls are available and any reliable standard equipment is satisfactory.
Heater controls should be installed to regulate the firing mechanism in direct proportion to the required output. These controls should increase or decrease the heat in-put to main tain the Aroclor 1248 at the operating temperature required by the heat-demand of the user. Small units may be operated satisfactorily by relatively simple "on-off' or "high-low" con trollers; larger units may operate more uniformly if equipped with modulating temperature controls.
User Controls should be installed to regulate the flow of the heat transfer fluid in direct proportion to the heat-con sumption of the heat-using equipment. In a multiple-user sys
tem, separate controls should be installed on each consuming unit, to assure the proper heat-delivery.
Safety Controls. In addition to activating controls, the heater must also be fitted with the proper safety controls to
meet the include:
A.S.M.E. requirements. Safety controls should
1. A high temperature limit control operating at the heater outlet to shut off the burner in the event of an excessive temperature rise.
2. A suitable low-limit temperature control to hold the burner at low fire until the Aroclor 1248 in the system reaches a temperature level of 18()T\
The low limit temperature control is essential because the viscosity of Aroclor 1248 is rather high at normal room tem perature. To avoid localized overheating upon start-tip, it is not advisable to apply full heat from the burner until all the fluid in the system has attained a viscosity that allows good flow and unimpeded circulation. Cold start-ups require slow up-heats.
Burners should be equipped with automatic ignition controls and flame failure controls. In wide-range firing opera tions, an over-fire draft control will increase the economy of operation. Induced draft fans are another factor which should be considered as a means of avoiding the expense of high chimneys.
Where they are needed throughout the system, good quality recording or indicating gauges should be installed.
COOLING EQUIPMENT
Where fast reduction of temperature is required, suitable air- or water-cooling installations may be used. If the cooler is to be a water-type unit, it is suggested that stainless steel tubing be used for the coils to avoid corrosion on the water side. If a cooler is installed in the system, low temperature limit con trols should also be installed to avoid excessive cooling that might raise the viscosity to the point of impeding the circulation in the system.
20 l*fg *
W{i tfPHWWpWJMU WUJi
i | JUWUIU.^
. i..
TOWOLDMONOQ20567
FILTERING EQUIPMENT When heating systems operated on Aroclor 1248 are run
continuously near the recommended maximum temperature of operation (600*F.), it is advisable to provide a filtering device that can be attached to the drain line of the storage tank. In this way discrete particles of dirt that may get into the system can be filtered out periodically. This is an advisable maintenance step since it will eliminate the danger of dirt clogging the valve seats or lodging in parts of the control mechanisms.
A small portable filter such as those manufactured by Honan-Crane Corporation (Lebanon, Ind.) or Sparkler Manu facturing Company (Mundelein, 111.) is quite satisfactory.
CONNECTIONS and GASKETS To minimize the possibility of Aroclor leakage, welded
rather than threaded screw connections should be used. All connections %-ineli and over should be of the flanged type, fastened with alloy Iwlts; spiral-wound gaskets of corrugated stainless steel and asbestos should be used with flanged con nections. For three-inch lines, 300 pound flanges fitted with eight three-quarter inch bolts should be employed. As a joint compound, a product like "Q" Seal* has been found useful. In all cases, steel connectors arc recommended for all instruments and controls.
TESTING THE SYSTEM When a new system has been installed it is essential to
test for leaks. Testing with air should be avoided because of hazard
of rupturing pipes or jackets. Testing with water is not recom mended because it is difficult to remove residual moisture from the system which should be kept dry.
Halogen Testing for leaks is the recommended pro cedure. Introduce one pound of Freon F-12 or F-22 for each fifty cubic feet of volume of the heater and systern. Carefully introduce air not exceeding 10 psig. of pressure. With up to 10 psig. of air pressure, the con centration of Freon will be sufficient to give sensitive test results.
Attach a halide torch to an acetylene tank and light it. Using the lA inch hose as a probe, explore for leaks by passing the end of the hose along seams and joints. If a leak is present, the escaping Freon will be drawn
* A product of Quickley Co., Inc., 56 W. 115th St., New York, N. Y.
into the acetylene flame turning it green. A large leak will produce a violet color.
CLEANING THE SYSTEM After testing for leaks and making any required repairs,
the system must then be cleaned. A new system will contain dirt, mill scale and other
foreign particles. Unless removed, these particles will be sus pended by the Aroclor. They may then lodge in valves, con trols and mechanical equipment and cause faulty operation.
Purchasers of the heating equipment should request their suppliers to clean the equipment as thoroughly as possi ble, using brushes and wiping rags.
Where state or local codes require hydrostatic testing and cleaning with water, the procedure described by card No. 1 may he used. However, it is not easy to remove residual mois ture from the system. Since moisture is not desired in the system, testing and cleaning with water should be avoided whenever it is possible to do so.
Testing for leaks should be done as described above using Freon. After repairing any leaks, fill the system with ArocJor 1248, warm the fluid and circulate it thoroughly.
The Aroclor will serve letter than water for hydrostatic test ing and cleaning and will keep the system free from excess moisture. Since the Aroclor will pick up dirt and extraneous particles, it will be necessary to clean the fluid by filtration. To prevent filter arrangements, including screens from interfering with the required flow of Aroclor through the system, the filters must not l>e installed permanently in the line of flow. Tempo rary strainers in the suction side of the pump should be inspect ed frequently during initial start-up and removed when the system has proven clean.
The Aroclor should be cleaned thoroughly using a by-pass filter, eitlier a plattcn frame press fitted with dry filter paper and a thin bed of Attapulgus earth, or a convenient portable earthen cartridge type filter. Periodic use of this filtration equipment should assure that the Aroclor and the heating sys tem arc clean at all times.
In the event that the engineer chooses to carry out testing and cleaning using water, it is very important that all moisture be purged from the system during the early hours of operation. Details are given on Card No. 1. Following hydro static testing, periodic use of the filter equipment referred to above is desirable to keep the fluid and system clean.
0014466
21
j
I
n
GENERAL RECOMMENDATIONS for Operation and Maintenance
The following recommendations are primarily guides for the manner of using Aroclor 1243 in an operating system. They are supplemental to the equipment manufacturer's own recommendations for operation and maintenance that relate to the heaters or the heat-using installations themselves. The recommendations for start-up, shut-down, precautions in event of power failure, and periodic check-ups on the fluid and equip ment apply as generally accepted practice on all types and sizes of systems. By following these recommendations, the troublefree service life of the heat transfer fluid will be increased.
START-UP
When systems have been shut down for week-ends or over-night and the fluid is cooled to room temperature, follow this start-up procedure:
1. Start the circulating pump and check the expansion tank to make certain the Aroclor 1248 is at the proper cold-start level (Tank should be Vi-full.)
2. Start humor at minimum flame setting and continue full circulation until Aroclor 1248 is heated to 180F. when measured on the return side of the heater.
3. Turn heater up to full heat.
SHUT-DOWN
The following procedure will eliminate overheating of the fluid when shutting down:
1. Shut off burner completely with circulating pump still oper ating. Continue to run the circulating pump at full head for at least Vi hour to dissipate high residual heat in the com bustion chamber of the burner.
2. Shut off circulating pump at the end of Vz hour and switch off all heater electrical controls.
PRECAUTIONS IN COLD WEATHER
When heat exchanger is exposed to ambient tempera tures below 50F., it is recommended that unit not be shut down. It is recommended that the burner be turned low and the fluid circulated continuously at about 200F. The unit will then be "at ready" for immediate high temperature operation.
PRECAUTIONS IN CASE OF POWER FAILURE
In case of power failure, the burner circuit is interrupted by the heater controls. When power comes on, the circulating pump should first be run for a few minutes to eliminate any vapor pockets that might have been formed by the fluid's being held static in the hot combustion chamber. If there is no knock ing in the piping system, full-fire may be resumed immediately,
if the fluid temperature is above 180F.
PERIODIC CHECK-UPS The regular maintenance inspection schedule should
include the equipment manufacturer's recommendations and also inspection of the heat transfer fluid. The following is a listing of check points.
1. Lubrication of moving parts.
2. Operating fidelity and accuracy of readings of safety controls and teni|KTature limit controls.
3. Inspection of beater tubes, burner, refractory linings.
4. Periodic cleaning of beater surfaces. 5. Inspection of water cooling at the circulating pump.
6. Regular repacking of stuffing boxes according to the manu facturer's recommendations.
7. Semi-annual or annual sampling and analysis of Aroclor 1248.
Under normal operating conditions not affected by fre quent power failures or accidental overheating, when Aroclor 1248 is operated at 600 F. it should not be necessary to check on the condition of the fluid more often than once or twice a year.
The analysis for fluid condition is a simple determina tion of viscosity. The information given in Figure 6 serves as a guide to estimate the condition of the fluid, according to vis cosity values. Most users do their own testing; some have the viscosity determination made by an outside laboratory.
Customers can have their fluid tested by Monsanto free of charge. A one-quart sample is required, and sample should be carefully packed to avoid breakage in shipment. Samples should be shipped to:
Monsanto Chemical Company -
Organic Chemicals Division
Industrial Fluid Sales
St. Louis 24, Missouri
ABOVE INFORMATION APPEARS ON POCKET CARDS INSIDE BACK COVER
0019*67
\
TOWOLDMONOQ20569
oo
Designing or purchasing equipment for a heating system to be operated with Aroclor as a medium to deliver heat into a process requires consideration of heat transfer characteristics of both the user and the heater. Tlie actual heat which can be absorbed by a user, for example, depends upon the over-all heat transfer coefficient, heat transfer area, and a mean tem perature difference between Aroclor and the material being heated. Both overall heat transfer coefficient and mean temperature difference are, in turn, affected by the flow rate of the Aroclor. This inter-relation of flow rate, heat, and temperature is usually solved by a trial and error procedure as covered in standard reference texts. The approach of Granet(3) may be used to minimize or eliminate trial and error.
The following tables and graphs of physical properties and engi neering data are provided as an aid in layout and design calculations for systems to be operated with Aroclor 1248 as a heat transfer fluid in the liquid phase.
Table IV lists properties useful in heat balance calculations by which the flow rate is related to the heat transferred and the temperature change of the Aroclor. This relation is also shown graphically in Figure 10.
The over-all heat transfer coefficient for the heater or user may be estimated by the methods outlined in the texts of McAdams^) or Kern(*). This is usually done by combining the individual film coefficient of the Aroclor with other coefficients and conductivities to yield the over-all coefficient. Table V contains physical properties of Aroclor as a function of temperature which arc needed for calculating the Aroclor film coefficient. Table VI gives typical film coefficients for Aroclor flowing through a 0.81 inch i.d. tube. These are listed as a function of temperature and flow rate in a tubular heat exchanger. Other tube sizes would, of course, require a correction for the diameter in the Reynolds and Nusselt group of the equation (from McAdams) given at the top of Table VI. Correlations for estimating film coefficients for various materials that might be processed by indirect heating may be found in the texts cited (*), (5) and elsewhere in the literature.
For sizing pipe lines and pumping requirements, Figure 11 shows pressure drop vs. flow rate and pipe size for Aroclor 1248 at temperatures over 300F. Above this temperature Aroclor 1248 flows freely like water.
A bibliography appears on page 32.
TOWOLDMON0020570
\\
Temperature "f. CC.
32 0 40 4 50 10 60 16 70 21 80 27 90 32 100 38 110 43 120 49 130 54 140 60 150 66 160 71 170 77 180 82 190 88 200 93 210 99 220 104 230 110 240 116 250 121 260 127 270 132 280 138 290 143 300 149 310 154 320 160 330 166 340 171 350 177 360 182 370 188 3B0 193 390 199 400 204 410 210 420 216 430 221 440 227 450 232 460 238 470 243 480 249 490 254 500 260 510 266 520 271 530 277 540 282 550 288 560 293 570 299 580 304 590 310 600 316 610 321 620 327 630 332
TABLE IV THERMODYNAMIC PROPERTIES OF AROCLOR 1248
Enthalpy Btu./lb.
0.000 2.162 4.881 7.616 10.367 13.134 15.917 18.716 21.531 24.362 27.209 30.072 32.951 35.846 38.757 41.784 44.727 47.686 50.661 53.651 56.657 59.679 62.717 65.771 68.841 71.927 74.029 77.147 80.281 83.431 86.597 89.779 92.977 96.191 99.421 102.667 105.929 109.206 112.499 115.808 119.133 122.474 125.831 129.204 132.593 135.998 139.419 142.856 146.309 149.778 153.262 156.762 160.278 163.810 167.358 170.922 174.502 178.098 181.710 185.338 188.982
Cp (Spec. Heat) Btu./lb./*F.
0.2695 0.2711 0.2727 0.2743 0.2759 0.2775 0.2791 0.2807 0.2823 0.2839 0.2855 0.2871 0.2887 0.2903 0.2919 0.2935 0.2951 0.2967 0.2982 0.2998 0.3014 0.3030 0.3046 0.3062 0.3078 0.3094 0.3110 0.3126 0.3142 0.3158 0.3174
0.3190 0.3206 0.3222 03238 0.3254 0.3269 0.3285 0.3301 0.3317 0.3331 0.3349 0.3365 0.3381 0.3397
0.3413 0.3429 0.3445 0.3461 0.3476 0.3492 0.3508 0.3524 0.3540 0.3556 0.3572 0.3588 0.3604 0.3620 0.3636
0.3652
Density lbs./eu. ft
91.6 91.3 90.9 90.6 90.2 89.8 89.5 89.1 68.8 88.4 88.1 87.8 87.4 87.0 86.6 86.2 85.9 85.6 85.2 84.8 84.4 84.1 83.7 83.4 83.1 82.9 82.6 82.3 81.9 81.6 81.2 80.9 80.6 80.2 79.8 79.4 79.1 78.8 78.5 78.2 77.9 77,6 77.2 76.8 76.4 76.1 75.7 75.4 75.0 74.7 74.4 74.1 73.7 73.4 73.0 72.7 72.4 72.0 71.7 71.4 71.0
Lbs./gaf.
12.22 12.19 12.13 12.08 12.03 12.00 11.96 11.91 11.87 11.82 11.77 11.73 11.69 11.64 11.58 11.53 11.47 11.42 11.38 11.34 11.29 11.24 11.18 U.14 11.10 11.06 11.03 10.98 10.94 10.90 10.85 10.81 10.76 10.71 10.67 10.62 10.57 10.53 10.48 10.43 10.39 10.34 10.30 10.25 10.20 10.16 10.11 10.06 10.02 9.98 9.94 9.90 9.85 9.80 9.76 9.71 9.67 9.63 9.58 9.53 9.48
Specific Gravity
1.47 1.46 1.455 1.45 1.445 1.40 1.432 1.425 1.420 1.414 1.409 1.404 1.400 1.493 1.387 1.381 1.375 1.370 1.365 1.359 1.353 1.348 1.342 1.336 1.331 1.326 1.321 1.316 1.311 1.305 1.300 1.296 1.291 1.286 1.280 1.274 1.269 1.264 1.259 1.253 1.248 1.243 1.237 1.231 1.225 1.220 1.214 1.208 1.202 1.196 1.191 1.186 1.180 1.175 1.170 1.165 1.160 1.155 1.150 1.144 1.138
Absolute Viscosity in Centipoises
850 380 200 115 66 47 32 24 18 14 11
9.1 7.5 6.3 5.2 4.4 3.9 3.35 3.00 2.68 2.38 2.08 1.96 1.82 1.68 1.58 1.46 1.42 1.30 1.22 1.15 1.10 1.05 1.00 0.96 0.91 0.87 0.84 0.80 0.76 0.73 0.71 .068 0.65 0.61 0.60 0.57 0.55 0.53 0.51 0.49 0.47 0.45 0.43 0.42 0.40 0 39 0.37
0019 A 69
TEMPERATURE DIFFERENTIAE F OFAROCLORENTERINGANDLEAVINGTHEUSER
FLOW RATES FOR AROCLOR 124S
Temperature
F. c.
32 ' 0 40 4 50 10 60 16 70 21 80 27 90 32 100 38 no 43 120 49 130 54 140 60 150 65 160 71 170 77 180 82 190 88 200 93 210 99 220 104
230 no
240 116 250 121 260 127 270 132 280 138 290 143 300 149 310 154
TABLE V THERMODYNAMIC PROPERTIES of AROCLOR 1248
PRA NDTL
Absolute
Lbs. Hr. Ft
Thermal Conductivity
Btu.
Ft. Hr. F.
r^T'
k kCp>*
iL h J
Temperature
Absolute Viscosity
Hr. Ft.
Thermal Conductivity
Btu.
Ft. Hr. F.
Cp M k
2060 960 485 273 160 114 77.5 58.0 43.5 33.8 26.6 22.0 18.2 15.2 12.6 10.6
9.45 8.10 7.26 6.48 5.76 5.03 4.75 4.40 4.07 3.83
0.0577 .0576 0.575 .0574 .0573 .0572 .0570 .0569 .0568 .0566 .0565 .0564 .0563 .0562 .0560 .0559 .0558 .0557 .0555 .0554 .0553 .0552 .0550 .0549 .0548 .0547 .0546 .0544 .0543
9844 4430 2353 1361 789 566 388 293 221 173 137 115
95 80 67 57 51.1 44.1 39.8 35.9 32.1 28.2 26.8 25.1 23.4
222
39.5 28.7 22.3 17.9 14.4 ' 12.6 10.8 9.7 8.7 . 7.88 7.15 6.68 6.18 5.78 5.38 5.05 4.83 4.55 4.36 4.18 4.00 3.81 3.73 3.63 3.53 3.45
'
320 330 340 350 360 370 380 390 400 410 420 - 430 440 450 460 470 480 490 500 510 520 530 540 550 560 570 580 590
600
160 166 171 177 182 188 193 199 204 210 216 221 227 232 238 243 249 254 260 266 271 277 282 288 293 299 304 310 316
3.53 .0542
20.6
3.34 .0541
19.6
3.14 .0549
18.5
2.95 .0539
17.5
2.78 .0537
16.7
2.66 .0536
16.1
2.54 .0535
15.4
2.42 .0534
14.8
2.32 .0532
14.3
2.20 .0531
13.7
2.10 .0530
13.1
203 .0529
12.7
1.93 .0527
12.3
1.83 .0526
11.7
1.75 .0525
11.3
1.71 .0524
11.0
1.64 .0523
10.7
1.57 .0521
10.3
1.51 .0520 . 10.0
1.45 .0519 ; 9.67
1.38
.0518
- 9.26
1.33 .0516
9.00
1.28 .0515
8.72
1.22 .0514
8.36
1.18 .0513
8.14
1.13 .0512
7.85
1.09 .0510
7.63
1.04 .0509
1.01 .0508
7.33 7.16
L. kk
3.35 3.29 3.22 3.15 3.08 3.04 2.99 2.94 2.90 2.85 2.80 2.76 2.73 2.68 2.64 2.61 2.58 2.54 2.51 2.46 2.43 2.40 2.37 2.34 2.31 2.28 2.25
2.22 2.20
0019*71
0019*72
TABLE VI HEAT TRANSFER DATA for ABOCLOB 1248
HU* COEFFICIENTS
GO- KTK] (WcAdams;
Biud m flow throegh 9.11' I. D. febe (1' 1 -1 *3 12-) exprassed a 8t*./$t. ft./hr./'T.
F.
150 200 250 300 350 400 450 500 550 600 ,
fl0W RATE, 6PM. 1.0 2.0
33.5 40.5 45.3 49.0 53.3 56.3 60.5 64.2
44.9 58.5 70.1 79.0 85.5 93 98 105 112
3.0
63.4 80.9 97 109 118 128 136 145 155
4.0
78.7 102 122 137 149 162 171 183 195
5.0
94.0 122 146 164 178 193 204 219 233
6.0 83.2 109 141 169 190 206 224 236 253 269
7.0 86.2 124 159 191 215 232 253 267 286 305
8.0 93.8 138 177 212 239 259 282 297 319 339
9.0 103 151 195 233 262 284 309 327 350 373
10.0 114 164 212 254 286 309 336 356 381 405
Calculations for other pipe sizes can be made using the data found in Tables IV and V. No tUm coefficients wort calculated for flow rates whore the Reynolds number was lass than 2100.
11.0 123 179 229 274 309 334 363 383 411 437
12.0 130 191 245 294 331 358 388 411 441 469
27
FRICTION LOSSES IN SYSTEM PIPING AROCLOR 124S, ABOVE 300PF.
\
HEAD LOSS, FT. PER 100 FT.
o o i^ 73
Figure 11
SSS3SS
-
FLOW RATE, GALLONS PER MINUTE
i~ |l^||* 2-
gi giiO ig i8ig
p 'lJigl-1,1^ till.II I ',l|. l\a ...
V
TOWOLDMONOQ20575
TYPICAL HEATERS
USING AROCLOR
1248
T
A 200,000 Btu. (right) and a 300,000 Btu. heater, both gas-fired, have been in use at Monsanto for over 14 years for organic chem icals reactions. The heaters have operated near 600F. with the same charge of Aroclor 1248 for periods of 7 years.
29
TOWOLDMONOQ20576
o o i'*'.
30
0019475
RIGHT 1 A 40,000 8tu. per hour electrically heated ' portable heat exchanger used to heat I vessels of about 50 gallons working capacI ity. This unit was built for a variety of j small scale chemical reactions. It was | initially designed to vaporize approxii mately 200 lbs./hr. of an organic comI pound which has a heat of vaporization ! of 150 Btu. per pound; a 30% heat loss
was allowed for. Experience with the ; heater indicates that a horizontal rather ; than the vertical mounting of the immerj sion heater (at operator's left) would have 1 been more satisfactory.
FAR RIGHT
A 4,000,000 Btu./hr. forced circulation j International laMont heater.
I
( RIGHT ' Control panel for a 3.000,000 Btu./hr. | International LaMont heater that oper: ates the 3,500 gallon, glass-lined kettle j shown on the left. This kettle is the
largest of its kind in the United States.
FAR RIGHT Commercial heaters operating on Aroclor 1248 are available in any capacity desired. This is a 1,200,000 Btu./hr. installation.
.1 I I i
l
TOWOLDMONOQ20578
9ZV6 T00
(Photo Courtesy Patterson Foundry and Machine Co.)
(Photo Courtesy Union Iron Works)
FAR LEFT
A pilot plant resin processing vessel operated on indirect heat transferred by Aroclor 1248. Vessel and heater are mounted together in one unit.
LEFT This 500,000 Btu./hr. forced circulation heater is electrically heated and designed for a liquid temperature of 500 f. The construction is similar to a double pipe heat exchanger with the electric heating elements in the inner pipe; the Aroclor 1248 circulates through the annular space between inner and outer pipe. The liquid Aroclor 1248 is delivered from the heater at a temperature of 500f. and heats the contents of a jacketed kettle with a batch capacity of 1.000 gallons.
i f
i
r:~
I - ?; ,
V
CV .
`Hr
! nr 1 j cv
^-
,r> .
k
j:
w ww?
.i
i jpw^ijpu Un
This design for a forced cir culation heater was de veloped by Cleaver Brooks Company.
LITERATURE CITED
1. Monsanto Chemical Co., St. Louis, Mo., Application Data Bulletin O-P-115 (1954).
2. Sullivan, M. V., Wolfe, J. K., and Zisman, W. A., "Indus. Lug. Chem.," 39, 1607 (1947).
3. Granet I., Heat Transfer Performance Curves", Chemical Engineering, P. 1S7-190, March, 1955.
4. McAdams, W. H., "Heat-Transmission", McGraw-Hill Book Co., Inc., New York, (19-12).
5. Kern, D. Q., "Process Heat Transfer", McCraw-Hill Book Co., Inc., New York' (1950).