43--Fire Protection
Flameproofing wood and fabrics
Fire-retardant treatments. Wood cannot be made fire resistive, but it can be treated to retard both the rate of flame spread ovei its surface and the rate it contributes fuel to the fire There are two methods for treating wood impregnation and use of fire-retardant coatings Water-soluble treatments .11 e nor suitable for exterior use
Fne-ietardant coatings reduce the hazard from small fires in existing structures Onlv those makes listed by Underwriter' Laboiatones, Inc, should he used Effective im pregnation can usually be done onlv bv com panies equipped to do this woik
Fire-retardant coatings on wood should he applied m accoidance with the application specifications which pioduce the desned de gree of 1 eduction of flame spiead Thev mav have to be renewed at frequent mteivals, especially if the wood is exposed to lam 01 excessive moisture Ready-mixed fire-ietardant paint is commeicially available, but espe cially mixed piepaiations can also be made Regardless of the tieating method employed, engineering data can be obtained from the supplier of the treated wood 01 the manufactuier of the ti eating chemicals
Flame-retardant fabrics Fahucs cannot be made noncombustible, 1101 even lesistant to chairing or to decomposition, but chemical treatment will 1 educe their flammability (See NFPA Standard No 701, Standard Methods of Fiie Tests for Flame-Resistant Textiles and Films ) Some treatments merely inhibit the rapid spiead of flame, whereas otheis prevent flames and depress dangerous afteiglow
Where the only anticipated exposuie is to small spaiks, small flames, or tempeiatuies up to 400 to 500 F, flame-i etardant canvas is often preferred to asbestos 01 chiome-tanned leather paiticularlv wheie flexibility, duiabilitv, strength, and lesistance to abrasion aie lequned Asbestos 01 chrome leather is lequired for moie serious exposures, such as heavv welding, fire fighting, or foundiv work
There are two pnncipal tvpes of fireretardant treatments for fabrics water-soluble and weather-resistant 01 water-insoluble Commercially available or homemade watersoluble treatments aie effectne, but must be
1384
leapphed aftei each laundering Seveial com mercially treated fabrics are listed by Under writers' Laboratories, Inc Samples of treated materials should be tested periodically aftei each application to assuie satisfactory peiformance
Water-insoluble chemicals, such as chlorin ated paraffin, chlonnated resin, 01 certain inoiganic chemicals, form the basis of weatherlesistant, fire-iesistant finishes for canvas, duck, rayon, and othei fabrics used foi awnings, tenting, tarpaulins, truck covers, and welding curtains Satisfactory weatheilesistant treatments requne special processing of the fabnt which can be done best by the finishing mills 01 chemical companies equipped to do this work
Fire and emergency dnlls
Regardless of what method is used to alert employees, they should thoioughly under stand what the signal means and how to lesponcl 111 the safest possible manner Tiaming employees to leave then woikplace piomptly on proper signal, and to evacuate a building speedily but without confusion, is laigelv accomplished through file 01 emer gency dulls Exit dulls must be caiefullv planned and cained out m a senous mannei under ngid discipline Periodic instruction sheets should be distributed to all employees, and an exit dull organization formed fiom the supeivisoiv staff
Fne dnlls at fiequent mteivals also demonstiate management's concern and smceie in terest in all fire prevention and fiie piotection activities The drills should serve as a leminder to employees and supervisor that mles, such as those on "No Smoking," and other fire pievention piactices aie impoitant
Emergency exit dulls also serve as a valua ble check on the adequacy and condition of the exits and alarm system Any deficiency should be immediately and permanently col lected Caieful plans must lie made to elim inate the possibility of panic m the event of an emeigencv, legai dless of cause, and to guaiantee the smooth functioning of the emei gencv plan Reference should be made to the NFPA Standard No 7, Management Control of Fire Emergencies Also see Chapter 18, "Planning for Emergencies," eailiei in this Manual