Document 0Jq4aQ472DVZOkwxLNDqZ3jMR

Wednesday, December 28,1960 FEDERAL REGISTER <\ 13817 to give the nip-point of the belt and covered with safety sleeves or where they 12 square feet, additional frame mem pulley the maximum protection. are used parallel with the shafting and bers shall be provided to maintain panel (c) If the cone is located less than are countersunk or else do not extend area within this limit 3 feet from the floor or working plat beyond the flange of the coupling. (5) All joints of framework shall be form, the cone pulley and belt shall be guarded to a height of 3 feet regardless of whether the belt is endless or laced with rawhide. 50-204.168 Gears. Gears shall be guarded in accordance with one of the following specifications: (a) A complete enclosure. (b) A standard guard as described in section 204.181 at least 7 feet high ex tending 6 inches above the mesh point of the gears. (c) By a band guard covering the face of the gear and having flanges extended Inward beyond the root of the teeth on the exposed side or sides. Where any portion of the train of gears guarded by a band guard is less than 6 feet from the floor a disk guard or a complete enclosure to the height of 6 feet shall be required. g 50-204.169 Sprockets and chains. Guard Standards for Mechanical Power Transmission 50-204.179 Materials. (a) Standard conditions will be se cured by the use of the following ma terials: Expanded metal, perforated or solid metal or wire mesh on a frame of angle iron or iron pipe securely fastened to floor or to frame of machine (see sec tion 50-204.181). (1) All metal shall be free from burrs and sharp edges. (2) Wire mesh shall be of the type in which the wires are securely fastened at every cross point either by welding, soldering, or galvanizing, except in case of diamond or square wire mesh made of No. 14 gauge wire. inch mesh or heavier. tb> Design of guards: (1) Where it is necessary to change made equivalent in strength to the ma terial of the frame. 50-204.180 Disk, shield, and "U" guards. <a> Disk guard: A disk guard shall consist of a sheet-metal disk not less than No. 22 gauge fastened by "U" bolts or rivets to spokes of pulleys, flywheels, or gears. Where possibility of contact with sharp edges of the disk exists, the edge shall be rolled or wired. In all cases the nuts 6hall be provided with lock nuts which shall be placed on the unex posed side of the wheel. (b) Shield guards. (1) A shield guard shall consist of a frame filled in with wire mesh, expanded, perforated, or solid sheet metal. (2) If area of shield does not exceed' 6 square feet the wire mesh or expanded metal may be fastened in a framework All sprocket wheels and chains shall be enclosed unless more than 7 feet above the floor or platform. Where the drive extends over other machines or working areas, protection against fall ing shall be provided. g 50-204.170 Openings for oiling. belts, make adjustments or apply oil or grease, guards shall have hinged sec tions or be removable. <2) Guards shall be designed so as not to interfere with the usual machine op erations, but give the maximum protec tion to the operator. (c) Methods of manufacture: When frequent oiling must be made., (1) Filler material shall be expanded openings with hinged or sliding self- metal, sheet or perforated metal, or closing covers shall be provided. All wire mesh and be securely fastened to points not readily accessible shall have oil feed tubes if lubricant is to be added while machinery is in motion. g 50-204.171 Friction drives. frame. (2) By welding to frame every 4 inches. By weaving through channel or angle frame, or if No. 14 gauge % inch mesh or heavier is used, by bending en (a) The driving point of all friction tirely around rod frames. drives when exposed to contact shall be (3) Where openings in pipe railing guarded. are to be filled in with expanded metal, (b) All arm or spoke friction drives and wire or sheet metal, the filler material all web friction drives with holes in the shall be made into panels with rolled web shall be entirely enclosed. edges or bound with "V" or "U" edging of % inch solid rod, % inch x % inch x Vb inch angle bon or metal construction of equivalent strength. (3) Metal shields may have edges en tirely rolled around a % inch solid bon rod. AU material of shield guard shall meet the requirements of section 50-204.181. (c) ''tr* Guards: A VTJ" guard con sisting of a flat surface with edge mem bers shall be designed to cover the under surface and lower edge of a belt, multiple chain, or rope drive. It shall be con structed of materials specified in table of section 50-204.181 and shall conform to the requirements of sections 50204.183 and 50-204.184. Edges shall be smooth, and if size of guard requires, these edges shall be reinforced by rolling, wiring, or by binding with angle or flat bon. (c) All projecting bolts on friction of No. 24 gauge or heavier sheet metal 50-204.181 Approved materials. drives where exposed to contact shall be guarded. g 50--204.172 Ke;s, set screws, and oilier projections. All projecting keys, set screws and other projections in revolving parts shall be removed or made flush or guarded by metal covers. This does not apply to keys or set screws within gear or sprocket fastened to the panels with bolts or rivets spaced not more than 5 inches center to center. The bound panels shall be fastened to the railing by sheet-metal clips spaced not more than 5 inches center to center. (4) Where the design of guards re quires filled material of greater area than (a) Minimum Requirements. The materials and dimensions specified in this section shall apply to all guards ex cept horizonal overhead belts, rope, cable or chain guards more than 7 feet above floor, or platform. (For the latter, see table following section 60-204.184J Table or Standard Materials and Dimensions casings or other enclosures, nor to keys, set screws, or oil cups in hubs of pulleys less than twenty inches in diameter where they are within the plane of the Material Clearance from moving part at all poults Largest mesh or opening allowable Mlnlmnm ptt|tt (U.6. standard) or thicksets height of gnard from floor or platform level rim of the pulley. g 50-204.173 Collars. All revolving collars, Including split collars, shall be cylindrical, and screws or bolts used in collars shall not project beyond the largest periphery of the collar. g 50-204.174 Couplings. (a) Shaft couplings shall be so con structed as to present no hazard from bolts, nuts, set screws, or revolving sur faces. Woven wire................................... Expaudod metal........................... Perforated metal______________ Sheet metal.............. .................... Wood or mctel atrip croaaed Under 2"._........... 2"-4"____________ Under 4" 4"-16".................... Unflor 4"________ 4"-16".................... Under 4'' 4"-16"............... ... Under 4"________ 4''-18"........ ............ Under 4". 4~-l3". H"_~........... r._....... Under 4" M" width.. Wood or metal atrip not crossed. 4"-16".................... I" width... No.lfl No. U. No. 20. No. 14. No.2J_ No. 22fWood 44" (Metal No. IS (Wood 14"___________ Metal No. 16---- /Wood 44" (Metal No. 16 (Wood 44"_________ (Metal No. 18 rcr. rrroooeee... roe. TV'. TV'. TV*. TV'. TO". TV'. TV'. 7V'. TO". (b) Bolts, nuts, and set screws will, Std. ralL. however, be permitted where they are Min. l*_. Mac. 20"- jsee Standard for Railings Section 306JS6. No. 261--Part H- 2