ABD00308030 ABERDEEN PLANT VINYL CHLORIDE MONOMER OVEREXPOSURE SUMMARY FY 1992 DATE 2/17 2/17 4/1 5/9 6/16 7/10 9/14 JOB MECHANIC MECHANIC MECHANIC OU -A" OP MECHANIC MECHANIC CHF. OP. SHTFT DAY DAY DAY NIGHT DAY DAY DAY SAMPLE 3.02 5.98 6.9 3.4 1.06 1.8 1.9 RESE. NO NO NO YES YES YES NO TASK CHANGING SPRAYHEAD - 745 RX CHANGING SPRAYHEAD - 745 RX BLANKED D-500 CONDENSER CHANGING VCM FILTERS REMOVED BLANK FROM RECOV. LINE CHANGING OUT 903 COMPRESSOR UNKNOWN FY 1993 11/15 11/19 2/24 3/3 3/15 3/25 MECHANIC MECHANIC SHFT SUP MECHANIC OPERATOR MECHANIC DAY DAY DAY DAY A DAY 25.8 1.5 21.33 11.7 6.9 2.0 YES NO YES NO YES NO RMV/RPLC RAM VALVE ON D400 CHG. RX SEAL ON 742 OPENED D600 RX - HYDRO LIQ. VCM LINE, WRKD ON CORKEN CHNG RING SEAL H20 FILTERS UNKNOWN