Document 0JMKrXk6wnbD7b5q3D6pJn4R

M. F. Baber - St. Louis October 2, 1970 UNDERGROUND POWER TRANSMISSION CONFERENCE P. G. Benignus R. H. Munch W. R. Richard J. G. Bryant R. Davis D. A. Olson/ T. L. Gossage Please find attached a list of handouts given out at the "Underground Power Transmission Conference" which I recently attended. The first three handouts are attached to the addressees* copy of this memo. The present status in underground power transmission is adequately described in handouts (2) and (3). Three possible business opportunities for our group are discussed below. However, because of Ismail volume of fluids consumed in power cables, and because some of these needs will not develop into signifi cant markets for smother 5 to 10 years, the business opportunities for Monsanto related to underground power transmission are limited. The tabulation below lists cable voltages which will be installed before 1980, the number of miles which will be energized during the three years from 1973 to 1975 and the type ^.underground cable system which will be used for^voltage level. Line Voltage 115 KV-230 KV 3^5 KV 500 KV 765 KV 1100 KV Above 1100 KV Miles Energized 1973-75 Type of Underground Cable System Overhead Underground 18,600 690 Mostly oil-filled pipe cableSome extruded P.E. 6,400 3,500 650 380 Pipe cable -- Force-cooled pipe cable Force-cooled pipe cable Probably Synthetic paper insul ation and Synthetic oil. Probably pressurized SFg, maybe force-cooled pipe cable with synthetics. Pressurized gas and cryogenic systems. DSW 201845 STLCOPCB4059912 2- Synthetlc Fluids and Papers sf?6 a'S. As indicated in the -attached table, most underground trans mission which will be installed before 1980 will be at 500 KV and below. For such systems, cellulose paper insulation impregnated with mineral oil or polybutene is satisfactory. Synthetic polypropylene paper impregnated with a compatible (synthetic?) fluid will probably be used for 765 KV under ground systems, but few of these will be installed before 1980. Synthetic papers, films and inpregnants for underground cables must be compatible with one another. There is presently no problem with compatibility, but there may be at 750 KV. For instance, mineral oil swells polyethylene film and paper too much. The Electric Research Council (ERC) has given 3M Company a contract to develop and test polypropylene synthetic paper. This will probably be the solid dielectric material used in 765 KV cables and some 500 KV cables. DuPont is also a likely producer of such a paper. This could be a business oppor tunity for Monsanto. As an aside, present thinking is that the solid insulation in cryogenic cables will be polyethylene paper or spun bonded polyethylene. If this market develops, it will not be significant until about 1980. Fluids are needed which are conpatible with polypropylene at as high a temperature as possible, certainly to lOO^C; 130C would be better. At 750 KV and/or at temperatures above 100C the dissipation factor and consequent heat generation of mineral oil goes up rapidly. The synthetic fluid should not have these limitations. A significantly higher price than mineral oil could be ob tained for a synthetic fluid which is eonpatible with paper and which retains an inherently low power factor at temperatures of 120C or above. Such a product might replace mineral oil for many lower voltage applications. Of course, a fluid which in combination with paper has a significantly lower dielectric constant than mineral oil/ paper would be desirable. A significant premium over mineral oil should be paid for its use at 500 KV and above. Below 350 KV, little premium probably would be paid. DSW 201846 STLCOPCB4059913 -3- Dodecyl Benzene This impregnant has a slightly bad name in the U.S. cable industry because it performed poorly in a series of ERC tests. However, many persons may not realize that the paper used in those tests contained contaminants which distorted test results, lhus, if this product is better than mineral oil or polybutene it may have a small market In high voltage cables. Dodecyl benzene was used in cables produced by Pirelli of Italy to connect a chain of islands off the New England Coast. It was used more for its hydraulic properties than its im proved electrical properties. Films Plastic films were investigated as potential cable wrap for 750 KV cables. They were discarded because they could not be completely saturated with fluid. As in transformers, the development of a film which can be completely saturated with fluid should yield a marketable product. An alternative solution would be to develop a method to form a high dielectric strength gel in the paper cable wrap. ms Atts. MICHAEL F. BABER DSW 201847 STLCOPCB4059914 UNDERGROUND POWER TRANSMISSION CONFERENCE HANDOUTS Attached 1. Program and Speakers . 2. Underground Transmission in the United States, A. F. Corry, Boston Edison Co., 1969 3. Developments in Underground Transmission R. C. Waldron, The Okonite Co., April 1970 Not Attached 4. Addresses of Registered Conferees and Leaders. 5. Present Underground Transmission Techniques, F. J. Bender 6. Gas Insulated Systems, ITE Imperial Corp. 7. Operating Parameters of Compressed-Gas-Insulated Transmission Lines, H. C. Doepken, et al., 19^9 8. A New Concept for Power Cost Underground Transmission and Termination, P.F. Pugh 9. Underground Power Transmission, A Report to the Federal Power Commission, 1966 (The Bible of Underground Power Transmission, approx. 200 pages) DSW 201848 STLCOPCB4059915 K (iVnI * & cCMit l! 5 Io f8 55 e> C/3 3 % so J: s m t: 1 F | <5 c . - it I S m> 9 o 5; "c J O# ^to ig si* 03 CO ^ CC X ?lo|?c i i 5= 0UI S $5 SSi.^QSsi AC Ul 0 3 Ul H Q_ Ul 09 > < o i JC g s o O ;: u? tc i1 .5 Ul 0 | S i i IS m cd o 0 Xc 9io9. ! |*- 0. i c 5UJ CO s c _ V 5 o T_T ' o - frs acl a= S = |io " . *> g : >. c5>o- E3 > < o 09 O) -n * e p0 3 o . s >X s 5 f s i i 33^0)0W OC o> too o*0 *^.. ' 5UJ jj a-- 9 g| > U (U ,, -o - 5 5U-U1C S Sc ,, h- S W .j OJ "O -1^23 *O*___ms____= s. "O a ^ e X e 'O c oo co o j= (UhS c : Jill 31 E i lc- 2 -a O1 ba. -*3 _2 _ I_ ; a 5 | co CD j= to > S CO 2 S 0 m L -3 UJD 0. 5 ss O *- "1 ws> g 3 _c =c03 UJ O 3a s 5 >- :!* < 06 5 tr ii :Z i111 -J "*0? UJ h* <M D j:- t. -JtJu'CcM 3< om wo oI_ 1-- s --s c 3 -3 = == <0 iu - , - ^ -o n E u. a> c c a Z eai ^j *0=1, =w --jm --o U.>^U.O<HCLUJmO< 1 1: cirni cini ott DSW 201849 T E L ./(6 0 8 ) 262-2061 (or Program tnformatio /(6O0) 262*1122 for Program Enrollmen STLCOPCB4059916 g | 2 5 2.S -- 3 a 2. 3 , --- .1 S' S -o o ^o X --u Q3- --m X tn F" ~ i -- 3 3 -- CD -n _. B " < QJ Q. - 3 ? 1 tO VI (O 3 2. Q. g 3 2 Cfl 3 05 3 QJ r 3 iC a:Ef . "< DSi rc- t--t) 5__" r2n r-i ffiS-jrSfS. -. rr Q_ s:T CO 3" 2 8 = ^ O 3 & 1 1 g ^-s 3 o -2. ? S S 3 Q. s 8- 3 = I* < 0 3 _. ?& .O ^ CO Q. |i s. 0 3. - ^3-6 i3 3 o! s; * Igf g 8 I ? iOZ ="ii . C ~ 05 g 3 g. co --8-ti3o < -t. 2<. 3 22 | I 8. if. 5 -3 3 05 -O C 9 m W------- =3 3Q. 3i 0 --05 -- CfflL -O W 3 to O o < 2. =r 3 - 2 < , - ~ ?2 i f-l m - i. " 3o & 3Z UNDERGROUND POWER TRANSMISSION September 24-25, 1970 < ilapartment of engineoring/UNIVERSITY EXTENSION/the university of Wisconsin UNIVERSITY EXTENSION The University of Wisconsin Department of Engineering 432 North Lake Strnnt Madison. Wisconsin 53706 UNDERGROUND POWER TRANSMISSION September 24-2$, 1970 /----* a . :: ; .: . DSW 201850 STLCOPCB4059917