Document 0JDrBLqv1Vm9803aB58bg7q2V
Autovent Fan & Blower Company 1809-23 N. Kostner Ave., Chicago, Illinois
FANS--BLOWERS
UNIT HEATERS
Member National Association of Fan Manufacturers and Industrial Unit Heater Associations
Coolvent Fan--Belt Driven Propeller Fan for com mercial and industrial applications as well as residential attic fan installations where large volume of air is
required with quiet operation at low initial and oper ating costs. Sizes from 24" to 54" diameter. Bulletin
No. 204-A sent on request. Autovent "31" Series Propeller
Fans--Will not churn air or overload the motor. Especially recommended for
economical ventilation. Ruggedly con structed. Capacities from 500 to 38,000 cfm. Write for bulletin No. 200.
X' X
Acid-moisture and Explosion Proof Fans--The acid-Moisture proof units are equipped with fully en closed motors and specially constructed fan wheels. The vapor-explosion proof units designed to handle ex plosive dusts and gases have underwriters label "Class 1 --group D" motors and non-ferrous fan wheels to meet the requirement,
bulletin No. 201.
Write for
AUTOVENT "31 SERIES" PROPELLER FANS
Constant or Two Speed--Alternating Current--Multiphase-- 220 or 440 Volts--60 Cycle
Size Type I6HMN I6HMR I8HMN 18HMR 20HMN 20HMR ' 24HML 24HMN 24HM
Motor HP
i/a
1/5 1/8
1/4
1/4 1/4 1/6 1/4 1/3
Cfm Max. 1700 1950 2350 2950 3450 . 3550 ! 3850 4500 5250
Appr.
Rpm Max. 1140 1725, 1140 > 1725 1140 1725
850 1140 850
Appr.
Shpg. Wt Lb
64 66 77 90 115 115 145 150 175
Size Type 30HML 30HMN 36HMT 36HML 42HMT 48HMT 54HME 60HME 72HME
Motor Hp
1/3 Vi Vx Va 1.0 V/i 2 i'h 3
Cfm Max.
Appr.
Rpm Max.
7100 850
8100 1140
10000' > 690
12500
850
13500
690
16900
690
21500
575
26500
480
38000
480
Appr.
wth
210 220
335 390 510 650 890 1200 1500
Autovent Uniblade Volume Blowers--Motor driven--universal discharge for fume hoods, chemical labs, processing, drying, forced draft, etc. Handles low volumes of air at medium pressures. Wheels range from 6 in. to 11 in. dia.--same design as heavy duty blowers. Can be mounted on floor, wall or ceiling. Direct Connected Blowers for general ventilating applications, available in wheel diameters up to 25 in. Bulletin No. 300. Forward Curve Belt Driven Blowers No. 301.
Autovent "V" Belt Driven Unit Blowers--Forwardly curved blade type with smooth air f\ow and quiet bearings. Motor mounted on steel pedestal, integral with blower housing, making a compact unit. Air delivery can be decreased or increased if desired. Interchangeable, motors. Sturdily constructed of sheet steel, rolled lock seams. Write for bulletin No. 300. Backward Curve Belt Driven Blowers No. 302.
Autovent Super-Type Steam Unit Heaters--This suspended type heater forces air circulation and directs warm air to lower part of room. Heating element of flat copper fins, attached to seamless, drawn copper tubes. Tubes run vertically for perfect drainage. No welded or brazed joints in coil or header. Fans have non-overloading power feature. Motor furnished to requirement. Write for bulletin No. 102.
The Complete Line of AUTOVENT Propeller Fans is tested and rated in accordance with the Standard Test Code adopted jointly by the National Association of Fan Manu facturers and the American Society of Heating and Ventilating Engineers.
970
1 V
A
Fans
Bayley Blower Company
s.I817 Sixty-Sixth Street Branches in Principal clues
Milwaukee, Wis.
Builders of Heating, Ventilating, Cooling, Purifying, Humidifying and
Air Washing Equipment; Exhaust and Drying Apparatus, Mechanical Draft and Blast, Fans and Blowers of all Types
Bayley Plexiform Fan:
Is a multi-blade fan for
supplying air for heating and ventilating systems, manufacturing processes, drying systems, forced and induced draft sys tems. It is suitable for handling high or low temperature gases at medium or low pressure. Will deliver maximum quanti ties requiring minimum space with great
economy. This is a distinct Bayley product, high
class material and workmanship, properly designed to avoid excessive vibration and overstressing of parts. Inlets and outlets are properly sjzed for maximum delivery and maximum efficiency. Fans are fur nished in single or double width of any required arrangement and with sleeve or anti-friction bearings.
Aeroplex Fan:
Is of high speed design with self limiting power characteristics. Application parallel to the Plexiform Fan. Highly efficient and quiet in operation.
Bayley Exhausters and Pressure Blowers:
Type "B" exhaust fan is for heavy duty, hand ling refuse from industrial and textile plants. Type "SE" is used in handling smoke, fumes and dust laden gases. Type " H " for high-pressure work. These units are highly efficient and of high class design and workmanship.
Bayley Turbo Air Washers, Humidifiers and De-Humidifiers:
The Turbo
Atomizer used in the
Bayley Washer pro-
duces a steady, fine spray. Water at low pres
sure is deliv ered . to the center of a rapidly re
The Bayley Turbo Air Wather Showing Turbo Atomizer and Eliminator
volving cone-shaped rotor provided with atomizing pins set in its periphery. This
atomizer requires very little attention, and will operate successfully under low water pressure. The orifices are large and this atomizer, unlike high pressure nozzles, cannot clog.
Bayley Chinook Heating Sections:
The Chinook sec tion is used with blast heating, venti lating and drying systems, and is suit able for high or low pressure steam cir culation. The base is divided into two chambers. Steam enters (see cut) the lower chamber, ris ing through H-in. pipes located within the 1^-in. pipes leading from the upper chamber. Condensation takes place in the larger pipes, the water falling into the upper chamber and draining away through the return outlet. The Chinook can be repaired in the middle of the bank without breaking steam connections or taking down a section.
Shipped assembled in smaller sizes, and . knocked down in the larger units. May be installed in horizontal or vertical position.
Bayley Chinookfin Heating Sections:
Are the same design as the Chinook Heaters, using heavy gauge copper fin tubes. As compared with Chinook it is much lighter and occupies less space.
Bayley Plexfin Unit Heaters:
This unit incorporates Chinookfin radiation and Plexiform or Aeroplex fans. The fan assem bly including top plate and motor is re movable as a unit for main tenance and inspection. The heating element is a re movable unit. Casing all welded extra heavy gauge. This is an exceptionally high grade unit at a moderate price.
971