Document 0J7dZJJkp5Jk9YObwmz0YXVqV

Monsanto 'TO r. w. Peterson - General Offices May 28, 1968 cc "cEA 1430 - EXPAND AROCLOR AT ANNISTON REVISED BIPHENYL TEMPERATURE CONTROL SCHEME RWP to WFT, 5/23/68, Same Subject W. F. Taffee Anniston S' JUN 4 1968 R. G. Corley B. D. Das L. L. Faulkner - Anniston R. A. Haydel - Anniston R. C. Herman/R., H. Henning W. H. Howard .< R. M. Kountz V. T. Langdon - Anniston P. K. Ward - Anniston H. L. Williams - Anniston Van Langdon has called to my attention ghat the biphenyl is available from storage day tanks at 100 C, not 85UC as in my memo. Thus, we may as well plan on transferring batches to the flaker feed tank at 100 C with 3-5 PSIG steam on the jacket. (This control would be bypassed for 100 PSIG steam to transfer Santowax.) In reviewing the desired biphenyl flaking temperature, I find that the Goslin Birmingham tests were run from 190-210UF and all successful. The 85C (185F) came from Department 221 WGK biphenyl flaking. Thus, the desired temperature is a balance of safety factor ig freeze-ups versus safe handling below the flash pgint. 50 F below the 123 C open cup flash point would be 95 C. My plan is to transfer batchesDin the evening, and with heat losses, we should be at 90-95 C by morning for flaking. If necessary, we can later add water to the plate coil intended for steam heating Santowax batches. A 35 ft2 plate coil will give 10C cooling to a 3,600 gallon batch in around three hours. ' We agree with Van's request to provide a level actuated cut off valve for safety against overfilling. Design will proceed on this basis. R.W. Peterson Project Manager 3s 0612744 TOWOLDMONOQ44866