Valves
Anderson Manufacturing Co.
Cambridge, Mass.
Manufacturers of VENT-RITE Air Valves (Balanced Radiation\
VENT-RITE Radiator Air Valves can be regulated to meet the venting requirements of any radiator. They can be set to correct unbalanced resistance and compensate for pressure drop, thus accomplishing controlled distribution and balanced radiation.
VENT-RITE Valves will balance the resistance op posing distribution of steam in a one-pipe job so that there are no laggingradiators. The venting capacity can also be restricted at desired points, to prevent overheating.
VENT-RITES, when installed on a thermostatically controlled heating system, can be so set as to allow all radiators to receive the desired amount of heat before the
thermostat shuts off. VENT-RITE Valves can be taken apart and cleaned
with the use of an ordinary strap wrench. All valves have a conventional union coupling with a heavy lead gasket which makes the joint leak-proof. The adjustment feature on VENT-RITE Valves is not obvious to the casual observer, but is readily, accessible, and once set, stays set,
in any desired position. VENT RITE Valves are made in both vacuum and non
vacuum types. The construction of the vacuum type does not . depend upon a ball or disc check to maintain
Vacuum in a system. This is accomplished by a sensitive and positive acting bellows, internally sub jected at all times to atmospheric pressure which elongates the bellows, and closes the vent when the internal pressure in the valve is less than the atmospheric pressure. This perfects an Inner
Vacuum Seal. VENT-RITE Radiator Air Valves are noiseless
in operation, positive in action, and seal by float action against water. They close thermostatically under temperature and will not Leak or sputter. All parts are made of the best material suitable for valves of this type, the valve pins being of nickel silver. The base is made of a brass drop forging. They are attractively finished in chromium plate. VENT-RITE Valves are guaranteed against de
fective workmanship or material.
Cross Section Verd-Rilc No. S-IVS
THE VENT-RITE LINE OF RADIATOR AIR VALVES
VENT-RITE No. I--(Automatic non-vacuum)--Yz in. side vent' for radiators. Variable venting capacity. Come-apart construction. Float seal against water. Closes thermostatically
under temperature. VENT-RITE No. 3--(Straight shank
automatic non-vacuum)--Y in. bot tom outlet. For risers, mains and con vection type radiators. Float seal against water. Variable venting capacity. Comeapart construction. Closes thermostatic
ally under temperature.
VENT-RITE No. 2-IVS (Vacuum)-- \/% in. side vent for radiators, with Inner Vacuum Seal, Variable venting capacity. Come-apart construction. Float seal against water. Closes thermostatically
under temperature. VENT-RITE No. 4-IVS (Vacuum)--
M in. bottom outlet. For risers, mains and
convection type radiators, with Inner Vacuum Seal. Variable venting capacity. Come-apart construction. Float seal against water. Closes thermostatically
under temperature.
934
Alco Valve Co., Inc.
REFRIGERATION CONTROLS
2628 Big Bend Blvd.
St. Louis, Missouri
THERMO EXPANSION VALVES
1. They assure positive, in dependent, automatic control of temperatures in each refriger
ated unit of a multiple system. 2. They automatically regu
late liquid feed and suction pres sure in accord with the refriger ating load in any unit thereby materially increasing the effici ency of the compressor as well as the evaporating coils.
3. They provide a positive method of obtaining a maximum wet interior surface in any type of evaporator.
4. They prevent the return of liquid refrigerant to the com pressor. . There is a size and type for all refrigerants and all capacities from fractional tonnage to 60 tons Ammonia, 50 tons Methyl Chloride, or 25 tons Freon.
MAGNETIC SUCTION STOP VALVES
Alco Magnetic Suction Stop Valves are designed for use on frosted lines as a suction line shut-off or as a low side by-pass valve. They are built without packing so as to operate successfully on heavily frosted lines' Makes pos sible individual control of two or more evaporating units in series on either a flooded system or a direct expansion system using a constant pres sure expansion valve. Built in Y in., % in., 1 in., l}4 in., \Y> in., or 2 in. sizes.
MAGNETIC BRINE VALVES
Alco Magnetic Brine Valves are packless valves suitable for controlling the flow of any non-corrosive liquid or gas. Since all working parts are entirely enclosed, the successful operation of the valve is assured even where the sur rounding atmosphere is heavily, laden with moisture or dust, or where the entire valve is covered with frost. Especially efficient on brine circulating, systems either as a by-pass or as a stopvalve^ Built in % in., 1 in., and \ x/i in. sizes.
MAGNETIC LIQUID STOP VALVES
Alco Magnetic Liquid Stop Valves are positive acting, and tight closing valves, designed for use with liquid refrigerants. They are indispensable wherever instantaneous closing of the liquid supply line is indicated. They are used extensively with expansion valves where the temperature difference between the refrigerant and the refrigerated substance or area is very small. They are also, used extensively with Alco Float Switches to maintain a. constant liquid level in flooded evaporators.
One type may be equipped
with a pilot switch incorporated in the magnet housing, and when so equipped, may be used, with a single pole thermostat, to simultaneously start or stop the flow of liquid refrigerant and start or stop the cornpressor motor. Other types, not having pilot switches are for use with double pole thermostats to accomplish the same
purpose. All types are available in all the
ordinary pipe sizes up to % in., and for tonnage capacities rang ing from fractional tonnage to 60 tons Ammonia, 30 tons Methyl Chloride, or 15 tons Freon..
ALCO FLOAT SWITCHES
The Alco Float Switch is a highly efficient control for the maintaining of a constant liquid level in'individual flooded evaporators. By means of its electric switch it operates a magnetic valve in the
liquid feed line, thereby maintaining the liquid level as desired.
Alco Float Switches are furnished for any A.C. voltage or frequency but are not available for D.C.