Document 09Q5ZmEjjXkpZVQjLqJ4gZ8m
Table 9. Coefficients of Transmission (V) of Concrete Construction Floors and Ceilings Coefficients are expressed in Bin per hour per squarefool per degree Fahrenheit difference in temperature between the air on the two sides,
and are based on still air (no wind) conditions on both sides.
TYPICAL CONSTRUCTION (j------ICT"--"v<LL00R'lH<3
Type op Ceiling
No Celling Y in. Plaster Applied Directly to Under Side
of Concrete Suspended or Furred Metal Lath and Plaster
0^ in.) Ceiling Suspended or Furred Celling of Plaster Board
(H in.) and Plaster (M in*) Suspended or Furred Celling of Rigid Insulation
(Y in.) and Plaster (Y in.) Plaster (Y in.) on Corkboard (IY in.) Set In
Cement Mortar {Y in.) on Concrete
OF
(Inches)
4 6 8. 10
4 6 8 10
4 6 8 10 '
4 6 8 10
4 6 8 10
4 6 8 10
TYPE OF FLOORING
Maple or Oak
No.
No Flooring
Yellow Pine Flooring* on
Flooring* on YellowTine
Tile or
(Concrete Bare)6
Wood Sleepers Embedded in Concrete4
Sub-Flooring* on Wood Sleepers
Flooring on Concrete
Embedded in
Concrete
ABCD
i 0.65 2 0.59 3 0.53 4 0.49
0.40 0.37 0.35
0.33
0.31 0.30 0.28 0.27
0.61 0.50 0.51 0.47
5 0.59 6 0.54 7 0.50 8 0.45
0.38 0.35 0.33 0.32
0.30
0.28 0.27 0.26
0.56 0.52 0.47 0.44
9 O'. 37 10 0.35 11 0.33 12 0.32 13 0.36 14 0.33 15 0.31 16 0.30
0.28 0.20 0.25 0.24
0.26 0.25 0.24 0.23
0.23 0.22 0.21 0.21
0.22 0.21 0.21 0.20
, 0.36 0.34 0.32 0.31
0.34 0.32 0.30 0.29 .
17 0.24 18 0.23 19 0.22 20 0.22 21 0.15 22 0.14 23 0.14 24 0.14
0.20 0.19 0.18 0.18
0.13 0.13 0.12 0.12
0.17 0.17 0.16 0.16
0.12 0.12 0.11 0.11
0.24 0.23 0.22 0.21
0.14 0.14 0.14 0.14
K-in. Battleship Linoleum Directly on Concrete
E
0.44 0.41 0.38 0.36
0.41 0.38 0.36 0.34
0.29 0.28 0.27 0.25
0.28 0.26 0.25 0.24
0.21 0.20 0.19 0.19
0.14 0.13
0.13
"Computed from factors marked by * in Table 2.
..
*The figures in Column A may be used with sufficient accuracy for concrete floors covered with carpet.
Thickness of yellow pine flooring assumed to be % in.
...
.,
``The figures in Column B 'may be used with sufficient accuracy for maple or oak flooring4 applied directly over the concrete on wood sleepers.
Thickness of made or oak flooring assumed to be in.
>
o
//
122
(U)Table 10. Coefficients of Transmission
of Concrete Floors on Ground with Various Types of Finish Flooring.
Coefficients are expressed in Btu per hour per square foot per degree Fahrenheit difference in temperature between the ground and the air oner the floor, and are based on still air (no ttitnd) conditions.
TYPICAL CONSTRUCTION CONCfitra /PLOOfclNC
' ""LA^ ''CeHcRtTfi
IPUULATtON &e.TW(JlN
two WatRPR.ooping towi/e /
Thickness
OF Concrete
No.
. (Inches)
No Flooring
(Concrete Bare)
TYPE OF FINISH FLOORING
Yellow Pine Flooring6 on Wood Bleepers
Resting on Concrete
Maple or Oak Flooring* on
Yellow Pine Sub-Flooring on Wood Sleepers Resting on
Concrete
Tile or Terrawo4 on Concrete
X-b. Battleship linoleum
Directly on Concrete
Type and Thickness of Insulation
ABcDE
None*
4 1 1.07 6 2 0.90 8 3 0.79 10 4 0.70 4 5 . . 0.66 8 6 0.54
0.35 0.33 0.32 0.30
0.29 0.27
0.28 0.27 0.26 0.25
0.24 0.23
0.98 0.84 0.74 0.66
0.63 0.52
0.60 0.54 0.50 0.46
0.44 0.39
1 in. Rigid Insulation* 1 in. Rigid Insulation* 2 in. Corkboard* 2 in. Corkboard*
4 7. 0.22 8 8 0.21 4 9 0.12
8 10 0.12
0.16 0.15 0.099 0.096
0.14 0.13 0.093 0.090
0.22 0.20 0.12 0.12
0.19 0.18 0.11 0.11
"Computed from factors marked by * in Table 2. ^Assumed % in. thick. "Assumed % in. thick. ^Assumed 1 in. thick.
"The figures for Nos. 5 to 10, inclusive, include 3-in. cinder concrete placed directly on the ground. The insulation Is applied between the cinder concrete and the stone concrete. Usually the insulation is protected on both sides by a waterproof membrane, but this is not considered in the calculations.
EC 3
yi
E>F
H
acsos
88
o
3ss Si