302 CHAPTER 13 1958 Guide Table 8. Summer Design Sol-Air Temperatures Used for Tables 9 and 10 Mean Sun Time Sol-Are Temperature Fahrenheit Degrees ` Any Sur face1* Horn. North East South West Ratio*: -7-- Jco 12 Midnight 1 AM 2 3 4 5 6 7 8 9 10 11 1 PM 2 3 4 5 6 7 8 9 10 11 24 Hr Avg C 0 0.225 0 0.225 0.125 0.225 0.125 0.225 0.125 77 76 76 75 74 74 74 75 77 80 83 87 90 93 94 95 94 93 91 87 85 83 81 79 . 83.1 77 77 76 76 76 76 75 75 74 74 74 74 76 74 91 75 106 77 119 80 129 83 137 87 142 90 144 93 140 94 132 95 120 94 107 93 96 91 90 87 85 85 83 83 81 81 79 79 100.5 83.1 77 77 77 77 77 77 76 76 76 76 76 76 76 76 76 76 76 76 75 75 75 75 75 75 74 74 74 74 74 74 75 80 74 74 74 74 110 93 74 74 74 74 123 100 75 75 75 75 126 103 82 '78 77 125 104 93 86 80 117 100 102 93 83 108 96 110 99 . 89 77 80 83 87 92 92 114 104 96 92 93 93 115 105 110 102 95 94 111 104 124 111 95 95 104 100 135 119 94 94 99 96 141 120 93 93 95 94 139 118 91 91 91 91 125 111 87 87 88 87 103 94 85 83 81 79 93.0 85 83 81 79 88.4 85 83 81 79 89.0 85 83 81 79 86.2 85 83 81 79 93.0 85 83 81 79 88.4 a surface absorptivity, dimensionless: root = 0.9; dark walls = 0.9, and light walla -- 0.5. fco = unit conveetive conductance = 4.0 Btu per (hr) (F deg). b values in this column are magnitudes of fo> the outdoor air temperature. of walls and roofs which appear in the literature.11 12 Both analytical and experimental studies have been made on the problem10 of heat flow through walls and roofs. Those concerned with a further study of the details of cooling-load estimates in particular relation to periodic heat flow will find much of value and interest in the reports of experimental studies of these problems.10- "1!-13-1415 The reader may also refer to the Cooling Load chapter of The Guide 1952 for the theory of heat flow through walls and roofs. PRACTICAL TABLES FOR CALCULATING SOLAR HEAT GAIN THROUGH WALLS AND ROOFS The analytical10 method reported by Mackey and Wright was used by Stewart16 to obtain temperature differentials based on Table 8 and shown in Tables 9 and 10. These analytical procedures, as well as those using Tables 9 and 10, presented here, yield generally higher rates of heat gain Cooling Load 303 than reported for Pittsburgh in early- A.S.H.A.E. experimental studies. Current authoritative opinion indicates a preference for analytical calcu lations. Thermal and physical properties of materials used in these tables are given in a paper.16 The rate of heat flow is obtained by multiplying the overall heat transmission coefficient of the structure by the equivalent temperature differential obtained from the tables. Tables 9 and 10 were developed by using an outdoor surface conductance of 4.0 and an indoor film conductance of 1.65 Btu (hr) (sq ft) (F deg). A reduction was made in the temperature differentials for roofs amounting to some 20 percent of solar radiation as explained by Stewart.16 This was to compensate for several factors, one of which is the radiant heat lost to the sky which is not included in the Mackey and Wright method. Recent experimental work by Parmelee17 and previous work by Brunt18 gives data showing the magnitude of this radiant heat loss from a roof or wall to the sky. Temperature differentials for roofs probably would be reduced be low those shown in Table 9 whenever the radiant heat lost to the sky is in cluded in calculation of sol-air temperature. The temperature differentials for roofs were based on an inside surface conductance of 1.65 because the charts prepared by Mackey and Wright10 used this value, and it was not considered practicable to repeat their work using a different film coefficient. An examination of the values given in their paper indicates that the tem perature differential would be changed very little even if a value 1.20 were used instead of 1.65. But to obtain the heat flow rates through roofs, more accurate values will be obtained if the overall heat transmission coefficient is calculated using 1.2 as the inside film conductance for summer. The roof coefficients of transmission for summer shown in Table 11 are based on surface conductances/cro of 4.0 for an outside roof surface and 1.20 for an inside ceiling surface. The outside conductance 4.0 is used for summer because it corresponds to a wind velocity of approximately 7.5 mph averaged for rough and smooth surfaces, and is more representative of summer wind velocities. Also, the lower wind velocity should be used in order to be on the safe side in determining the sol-air temperature. The inside conductance 1.20 is used because the convective portion of the film conductance for downward heat flow from a horizontal surface is appre ciably less than the winter conductance for heat flowing upward. Since there is little difference in wall transmission coefficients for summer, fin con^ucfances f 4.0 and 1.65, and the winter coefficients, based on 6.0 and 1.65, it is recommended that the overall coefficient U, for walls, be taken directly from the tables in Chapter 9 in which they are based on an outside film conductance of 6.0, corresponding to a 15 mph wind velocity. Advantages of Equivalent Temperature Differential Method The advantages of the equivalent temperature differential method of etermining the total heat transmission are given in following paragraphs, n are apparent from Examples 5 to 7. mission*6 sensible heat flow is obtained by multiplying the overall heat trans- Tables 9<and iq60*' ^' an<^ *'*'e equivalent temperature differential indicated in tion mavehem*> jrature differentials listed for a few representative types of construc- mission 0Il a" classes of walls and roofs, even though the overall heat trans- Dronort; coemcient is different, provided the structure has thermal and physical 3 AH* Slmilar t0 one of those listed in Tables 9 and 10. room andUS7ient8 can made, according to instructions given in the footnotes, for outdoor conditions different from those on which the tables are based.