Document 06vzmY9r64kM5wEpje7krg6RJ
FOR $U PONT USE ONLY
DATE October 20, 1976 TEST AUTHORIZATION NO. TA-C- 76-974
PRODUCT CODE NO.
s r ea "Ponsol**
TITLE
PRFPARFO RV-
W.
050 8l6 2000
POUNDS PRODUCT PROPOSED
100.000
BUILDING NAME "PonSO!" Intermediates
A Specific Gravity Method for the Determination of
Trichlorobenz ene in 2-t-AAQ, Crude
Evans
i,h./Z
4
_________AR_NE_DS_PTO_ENS_ST_IBCL_OE_NFCOL_RUS_TIOE_SN_T: __r-t__E_v_a_n_s,__R_.__P_a_s_s_arelli
PURPOSE o f TEST: To establish in the Plant a technique for determining when the trichlorobenzene content of 2-AAQ Crude being steam distilled in S-9 has been reduced to 50 + 5^*
d u r a t io n o f t e s t : Three months.
STANDARD INVOLVED: TMR-C-71-61, TA-C-76-834
ANALYTICAL CONTROL OR SPECIFICATIONS: t 3 No change
' 5d' Change described under Test Details
PROCESS HAZARDS REVIEW: [ J Required before test
W Not required
MATERIAL SAFETY DATA SHEET: [ ] Revision required y No change
PACKAGING AND SHIPPING CLASSIFICATIONS: C 3 Revision required W No change
TECHNICAL BASIS FOR CHANCE: 2957-135
TEST DETAILS: (Include Safety and Waste Disposal)
See attached.
Safety and Waste Disposal: No change.
DISTRIBUTION:
D. Ri, Baer, MI Lab. ' A. A. Baum, JL JL Files T. E. Lewis, D&C (3)
C. H. Lake, 588 Bldg D. Putnam, GAL (3) R. F. Stalzer, GAL R. I. Osmundson, D&C
R. Wiederhorn, D&C W.' Evans, JL JB* Passarelli, GAL Group Files (2)
APPROVED BY
^.r.AaXf tokvfrs
CHIEF SUPVfi.o MANUFACTURING
Not Required
QUALITY CONTROL OR ANALYTICAL*
Not Required
TE MANUFACTURING MANAGER*
DATE
Not Required
TECHNICAL DIVISION*
jdh ma r k "n o t r e q u 1 r e d " w h e r e a p p l ic a b l e uir_i<>K>> /n.,r. K u
Not Required
GEN, SUPT., MANUFACTURING*
OATE
Not Required
PLANT MANAGER*
Page 2 October 20, 1976 Test Authorization No. TA-C-76-974 2-1-Amylanthraquinone Crude
Test Details
Refer to current Operating Instructions by J. N. Leech May, 1976, Make the following changes:
Step
62. When the pressure gauge on S-9 reads zero and S-9 is vented, sample 500 cc of the charge and determine the percent TCB following the method described below.
Wearing rubber gloves, face shield and rubber apron, loosen the quick opening nozzle cover to be sure S-9 is not full to cover and that all pressure on S-9 has been released. Then, remove the cover for sampling.
2-AAQ Crude-Percent TCB
a. Place 500 cc of the 2-AAQ Crude into a 500 cc graduate.
b. Place a 20-inch long thermometer into the graduate and allow the liquid to cool to 25-50 C.
c. When the temperature range is reached stir the liquid with the thermometer to assurp uniformity. Read the temperature half way up the liquid column.
d. . Remove the thermometer and place a hydrometer having a 1.200 to 1.420 specific gravity range into the liquid.
e. Read the specific gravity immediately.
Read where the liquid touches the glass.
f. On the nomograph find the intersection of the temperature and the specific gravity.
g. If the intersection falls within the enclosed area, the percent TCB is 50 + 5$ and the lot can be drummed off.
Page 3
October 20, 1976
...
Test Authorization No. TA-C-76-97^
2-1-Amylanthraquinone Crude
h. If the intersection is above the enclosed area continue to distill.
i. If the intersection falls below the area, too much TCB has been removed and distillation should be stopped and the lot drummed off.
63. When TCB content is 50 + 5$, cool the charge in S-9 to 90C. for drumming.
S'
/Jdh
i
DUP050467757
? . Test Authorization No. TA-C-76-97^
N33001.01
So . 3 r
ZT