Document 06p37L47gvxkKgk3r6M7e80LO

OM ''KiivirmniicnUil Itrsnirch. 1'OH ICnviromnrnlAl Impsi t. A Heview liv Ihf Panel on HsrnrdmiK Tracf Substances", p 276, March )972. (10) Sniin, K. I). Mc('lm\ V K.. Mar Chem., 3. 337 (1976) (17) "HctlMcmV I hiithiicli fur Organisrlicn Clientic", Vo) i, Vicrl* Atinnj:r, HMVt (1H) Hidlrmni>. T K.OInrv.C. R.,Nr;cnrr. 17.7, M6(1974). (19) Ahlioll. |) C, M.irnson. H. H.. Taitnn. J O'G., Thompson, A.Mure, 211,2.'.!KlWf.l. (20) laitgimitr, I., J Mclroml , 5, 132(1948). (711 ('hamlierlnin, A ('.."Astiwts of Trawl nnd JVpoaition of Aerosol and Vspnr ('IihkIk". Hriliftli Kcporl AKKK HP/K-1261, 1943. (22) "Mrleorolcixy mid Alnmir Kiutkv 19t>8", I). H Slade, lid.. Til) 24190, OlcHrm^liouvc (or Federal Scientific & Technical In- formalina, NMS. S|inni:fi Id. Yn . )!f>8. (23) Kn*elmon. H .1.. IVik.ns, U W . Hagen, IV I . Heller, W. A.. "Washout Coefficient!. for Sflfcicd Oases end Particulates", Proc. Ii'llli Atniunl Mu I mi: Air Pollution ('.ml nil Assoc,, )9Wi. (24) Whuntly, ( A., linidinnii, J A.. Nature. 207,46K (196J). Rrrcii*cd for retnew Srptemhc 30, 1974 Arrrptnl Alov 17. 1970 Work partly supported by NOAA Office of .Sen Orant, Dept uf Commerce, under Grant No. UCSD Ot-J- 1M 22 Supplementary Mslcrisl Available. An annotated listing of the tomputer program in Fortran, wind direction and speed data tin,I an additional figure unll appear following thetr pages m the mi crofilm edition of this volume of the journal Photocopies of n,. supplementary material from this paper only or microfu he lt>r, , 148 mm, 24X reduction, ncgalitvt) containing all of the suppv mentary material for the papers in this issue may he oh/umt,I f, ,,m the llustncxs Operations Office, Journals Department, Ameru,,,, Chemical Society, 1155 16th St.. NW, Washington. DC 200:tt, Remit check or money order for f4 00 fw photocopy or $2 50 fur nu crofiche, referring to code number KS& T- 76-1223 A*-'- ' iPCT Contamination of the Environment (fear Sites ot Manufacture and Use Charles L. Stratton* and Jackson B. Sosebae, Jr. Lnvironmuntal Science & Engineering. Inc., P.O. Box 13454, Gainesville, Fla. 32604 A survey \v:ts conducted to assess the degree of environ mental coni am mation with polychlorinated biphenyls (ITU's) mill polychlorinated torphcnyls (lTT's) in the vi cinity of (hr single U S. manufacturing facility in Snuget, III., mid two users in (hr invest men! cast mg industry located in urhnn ('hiengn and suhurhnn Detroit. PC!) concentrations were loimif in soils as high ns 1H ppm near the manufacturer Hint ,Y2 ppm near one of (hr users. ITTY were detected as hiph as )K ppm in the vicinity of one user facility. The distribution of ITUs am! ITTY suggested an airborne mode of transport (min (he somec. Analysis of wastewaters indicated tin* diselmri'.e nf 1TKY nml l'( 'TY in t lie pg/l. level. Polychlorinated hiphenvli' (PCB's) have a basic chemical si nil lure ns shown in Figure 1. prom 1 to 10 cli.orme iitoins may lie attached to the sliueture, resulting in 210 possible isomers ITU's have certain physual properties, including hiph heal rapacilv, chemical siahility, ond excellent dielectric properties winch make them highly desirable for a number of industrial uses. Concern lias been expressed in recent years nver I he w idrsprend dis|K:rsion of ITU's in the environment. These compounds are suspected to have significant adverse efler ls on organisms at the lop of the iood well, including man. Uiomagnifintlion oi this contaminant in nalural predatorprry Iood clinins has been document'd by numerous studies. To complicate the problem, the rale of degradation of PCB's in the environment, particularly the higher substituted iso mers, is apparently exlremelv slmv This situation allows for signifirnnt areutmilulion of these persistent chlorinated or ganic comjaiumiK in the eiivirnnment. A thorough discussion of the pitihlcm and of the environmental data that are avail able has been presented by Sclikoff\l) and the U-S. Covemiiieni Interdepartmental Task l''oree (2). Polychlorinated terphenyls (I'CT's) have a similar but more limited industrial application. A grncialiaed ITT structure is ilhistiated in Figure 1. There exists little information con cerning ITTY in the environment. The environmental behiivini el' ITTY mov be expected to be similar to that of ITU's. The Monsanto Co. is the sole domestir producer of both ITU's and PCT's under the trade name of Aroelurs In ri* sponse to the rising concern over ITU's in tin* environment, the Monsanto Co. lias voluntarily taken two actions to ndu. < the environmental hazard. Beginning in 1070, the production of Aroclor was voluntarily reduced by the manufacturer, and supply was discontinued to Ihose users who could not coni ml release to the environment. Production of the more highly chlorine substituted Aroclor mixtures, including nil ITTY, hits since been curtailed oi discontinued, and a lower Mihsi i luted, refined mixture (Aroclor 1010) lias hern introduced Some research indicates the lower substituted ITB i-.omerdo not jK-rsisi as long in the environment ns 1 he higher miI> stituled isomers, and that they mnv be iitnenahle to hiologn .>1 degradation, hence reducing the potential hazards to I In < n vironment. A recent public announcement by Monsanto ('<. (January 1970) has indicated their intention to suspend all production of ITU's. JTB's are presently employed in electrical cap.-n itor-., transformers, vacuum pumps, and gas-transmission turlmn s (J). Both ITU's arid ITTY arc currently used in t he invest ment casting industry as a motor constituent of (lie \vn\ nu tvrinl used. This material is fashioned into the shape to he r,ii A refractory mold is then formed around the wax shape The wax is melted and poured from the mold, leaving the mold prepared for casting of the shape in mclal. The investment casting industry has not been supplied hv Monsanto Co. for several yenrs. ITU's and ITTY have been imported from foreign sources to meet this demand. I lui/.mgt r el al. (3) list the origin and trade name of foreign rmmnlac lured PCB mixtures. Sampling and Analysts A field sampling program wan conducted in rarlv )`)7:< under the direction of the Knvirnnmcnia! Protection Agcm \ to assess the effectiveness of voluntary coni rols hv indn>ir\ in eliminating the release of PCMY to the cnvironmeni Samples were taken in the vicinity of the domestic mainline luring facility and two 1TH and ITT user facilities. The production facility is located in ^nugcl, III., (he user f.n till ir are locoted in urban ('hiengo. III., and sulmrlmn l)elrmi. Mu h Hul h user* surveyed arc involved in the investment casting indusi ry Surfiicc* soil amnplcx were collected ol each site from the phint boundary lo n distance nf approximately 2000 m in four directions, subject to the physical constraints encountered. At cnch soil sample point, five MiliKsinple* were collected within a radius of HI m to a depth of 2.f> cm ovt r a J00 cm2 area. Vegetative matter was removal with forceps, and the five atilmamplcN were composited ami thoroughly mixed. This mode of sampling was designed to collect a homogeneous surface soil sample representative of the chosen sample point. Every attempt wns made lo select. wimple points where surface vegetation was sparse and where it uppcured unlikely wind scour would be n minor soil transport factor. Samples were placed in precleam-d wrde-mouth glass jars with aluminum foil-lined closures. Water samples were taken in 11. glass containers, com posited, and stored m 4-1. predefined glass-stoppered reagent hot ties. Soil samples were extracted in a soxhlet apparatus witli ):J o/niogrmle Ix-xauc/acetone. dri(*d with sodium sulfate, ami concentrated on a Kudcrnn-Dnnish apparatus. The pro cedure follows Mint pnwrribed by the ETA 14). Water samples were triple extracted with 15% nnnograde ethyl ether in hex ane, dried with sodium sulfate, and concentrated on 0 Kudemii-Dnmtdi apparatus ns described in EPA recommended procedures </>). Hoth soil and wafer sample extracts were clcnned on n adieu gel column, to remove interfering jicrI icidcs, oiling (he method of Snyder and Kciucrt (6) followed by a Milftoir ncid cleanup ns described by Murphy (7) All analyses were conducted by electron capture gs rhromatogruphv using 11 Vurian 2700 instrument. A 18-m, 3-inm i d , ijIiikk column packed with I..VI.96% 0V-I7/QF-1 011 a tlnnm Will', 80/100 mer.h support si 200 *C. was used for J'CH analysis. A 3% SI'-2401 glims column of length 1.1m and i.d It mm was opeialed at 220 *(' for analysis of )*CTV Mass Kpedrographic eonlimiation was obtained for selected sam ples (Junntilntion of the PCD ami TCT present was con ducted by electronic integration of the area of all peaks matching the most closely related Aroclor standard. h'vsutls and /)im.\ni<h I'C'H s were delected in soil samples from all three locations Kurvryrd. The gas chromatographic elution patterns most closely inntrlteci I hose of Arocli*r 1242 and Aroclor 1260 l)ecachlumbiphcnvl was present in samples taken at. two of the three sites. PCI"* were detected in soils at the urban Chicago location and in sediment.* at the suburban Detroit location. Manufacturing Facility. Aroclor* have been produced hv Mfmwmto Co. ut llic Sauget, JU-, ail/- ai/ire prior t> 1957. PCIt mixtures ranging from 16 to 6H% chiorine have been produced over the years, Production of the higher percent chlorine mixtures hns Item voluntarily reduced since 1970, and lower substituted isomers have Jieen introduced. Polychlori nated terphenyls ami chlorinated benzenes have also been produced at this facility. Terphenyi production was suspended in 1971 (8). The company operates a liquid injection inciner ator txi dis|M<H(- of in-housc liquid wastes and contaminated FCH'a. The environs of the facility are dedicated predomi nately to heavy industrial use with a limited amount of resi dential housing The rrmdts of the analysis of soil samples taken in the vi cinity af thin mamilncturing facility are summarised in Table 1. Aroclor 1242 was present in approximately one- half of the samples. A maximum of 10 ppm Aroclor 1242 was delected 600 in to the nort Invent. Aroclor 1260-was present in all snmples.Cmirentratiims ranged from 0.03 to 9.6 ppm. Decachlorobiphenyl was also detected in all samples at a concentration ranging from 0.049 In 2.4 ppm. Total J'CB concentrations of OJ.'i 20.7 ppm on dry weight basis were detected within a -A Figure 1. Basic chemical structure ot (A) polychlorinated biphenyls (PCB'sj and (8) polychlorinated terphenyls (PCI &{ Table I. Results of Analysis of Soil Samples Taken in Vicinity of Monsanto Co. Krumrich Production Facility in Saugct, III. Direction from from facility. fecilUy m Aroclor 1242 1ppm Aroclor Dtcechloro- 1200 biphenyl Tolul ecu SC 250 6.1 9.6 2.4 J8 ) NE 450 0.68 0.31 0.38 1.3 7 SE 600 3.0 2.9 J.3 7.2 sw 600 <0.01 0.65 0.12 0.7/ NW 600 10 9.6 13 20 / NE 620 <0.01 1.4 0.90 2.3 NE 700 <0.01 0.32 0.61 O./J NW 850 <0.01 0.03 0.40 0.4 3 NE 950 <0 01 0.05 0 097 0 13 SW 950 0.45 0.28 0.081 0 81 SE 1000 <0.01 0.20 0.27 0 -1 / st: 1050 0.82 1.3 1.6 3.72 NW 1100 0.46 0.39 0.12 0 07 sw 1250 <0.01 0.10 0 049 0 11. sw 1450 <0.01 0.26 0.08) 0.J4 hA /,'........ b rtONS 085854 0 25 ' 50 ?>- Figure 2. Typical chromatograms ol standard Aioclors, dacachk/iobi- phenyl, and soli sample taken m vicinity ol Monsanto Co . SuuquI. Wl (A)Aioriw (O) (tocad>ioM>tpn<nyl, (Ci Aior irw 17S0 (Dl toil nxtntri 1450 m rmliuKof the facility. No FfTT wor prewnt in Roils from this locution. A typical chromatogram of n noil snmpli- taken in the vi cinity of I hr Moniiimlo fmilitv is shown in Figure 2 along with the chrcimntt>gnim of several other PCH'k run under t he same instrument rnmiii ions. This particular soil sample contains 11 |))>m Aroelor 1 242.51.3 ppm Aroclor 12G0, and 1.0 ppm dernehlorobiphenyl, 1 ,ighter chlorinated Aroelor mixtures are likely present ns well. The instrument, condit ion* employed, however, do not give adequate separation of these mixtures Ut permit accurate quantification. The presence of decarhlorohiphcnyl at the concent rat ions observed is interesting. Decachlumbiphenyl has been reported as a component.of'only one Aroclor mixture (Aroelor 1268). Whether it may he a comiamenl of any of the lerphenyl mixtures produced or a by product is not known. Referring again to Table I. the higher I'CB concentrations are apparently at points closer to the facility with concen trations generally decreasing with increased distance. This distribution suggest* airborne transport of the PCBVt, inchiding detnchlorohiphenyl, from the manufacturing facility, with subsequent chrimsntion onto the surrounding land scape. AIM-li mirquisite sample from the inflttenl and the effluent, of the Hmiget village sewage treatment plant taken on Feb ruary 17 18, IH7?>, was provided by plant personnel. The Monsanto Co. uses this facility jointly with the village. Analysis (pg/l.) of these samples wars an follows: Influent Kffluenl Arnclor 1242 (i.K 4.5 Aroclor 126(1 8.7 4.7 Dccflchlnro biphenyl <0.01 <0.01 The treatment plant effects a reduction of 34% Aroclor 1242 and 46% Aroclor IVifiO. No dccachlorohiphenyt was detect ed. Investment Casting Facility, Chicago, III. Prior to 1972, Aroclnrx 5-I42,5 Hid, and (i(KKi were purchased and list'd by this industry in the compounding of investment, casting waxes. Subsequent to 1972,1'enelor l)K and Aroclor 5160 Inive been in use. Aroclois .'> 542 and 5 1(H) are lurphenyl mixtures with 42 and 60% chloi'ine hv weigh!. respectively. Aroclor 6090 is 90% terphcnyl and J0">'i Aroelor 1221. 1`Ynrlnr 1)K is n foreign supplied PCH (Collaro ('orp., Milan. Italy) consisting of nearly pure denichhnohi phenyl. The mamifncluriiig facility is shoaled in an orhnn neighborhood. Residential housing, parks, and a hospilnl me loctiled within a 3 km radius. The analytical results for soil samples at this site are tab ulnletl in Talile II. Aroclor 1200 was present in all samples, ranging from a low value of 0.22 ppm to a high of 1.8 ppm. Deeachlorobiphenyl was present in all hut two sample* wil l) h maximum concentration of 3.(1 ppm located 20 in from the facility. Total IH'H concentrations ranged from 0.22 to 5.2 ppm. I'm were also present in many of these soil samples. The gas chromatographic elution pattern dowdy matched t hat of Aroelor MOD. One J'(?T concentration us high as 13 ppm was measured. Figure 3A demonstrates that Fenrlor DK is nearly pure decnehlorobiphrnyl One minor peak elutes just before the predominate drcaehJornhipbenyl peak. The retention of the minor contaminant peak is such that it may he expected lo be an oetaiddorohiphenyl since it exhibits the same retention time ns the latest eluting peak in a standard Aroclor 1200 mixture. It is apparent by comparison of prak retention times with tin- sample chromatogram. Figure 3(\ that decnchlorohiphenv! is present in the soil sampled. The im-asuied con centration of diicnehloroliiphenyi in ibis particular sample was 1.2 ppm. The presence of decachlorobiphcnyl in this sample has been confirmed hv mass s|>eetroinelrv. The sample elution pattern also indicates the preseme of Aroclor 126(1 as can be seen by comparison with the Aroclor 12R0elution pattern. Figure 3B. The coneenlrntion of Anu lm 1260 in lliis sample is 0.63 ppm. There is no indication of degradation of the Aroclor 1260 since virtually all peaks m ihe sample chromatogram are present in the same relative pro portion as in the standard. There arc no significant. undefined peaks in the chromatogram following the acid cleanup mi cedure. Certain of the sample chromatograms inditoU' the presence of lower weight BCB's; however, the quantities present tend lo be far less than either Aroclor >260 or ticcachlorobiplirnyl At this site. Figure 4 is a gas chromatogram of a soil exirart from tins site showing the presence of various PCIVs, dccijrhlomhiphcnyl, and PCT. The J'CT present closely resembles the Aroclor 5460 shown. There cftiala no apparent spatial pattern of Aroclor i 26ti distribution over the study site. There iv little evidence m the data lo indicate the source of the Aroclor 1260 contammai ion Table II. Results of Analysis of Soil Samples Taken in Vicinity of an Investment Casting Facility m Urban Chicago, III. ~* Distance Direction from from facility. facility m Aroclor 1260 Dpm Decdditoro biphenyl Total PCS Arnclor 0460 NE 20 0.40 1.2 1.6 3.2 SC. 20 0.26 0.51 0.7/ 0.3H sw 20 1.5 0.75 2.25 4.? NW 20 16 3.0 5.2 13 E 450 0.69 0.58 17/ 4.1 NE 600 0.34 0.19 0.53 0.25 SW 620 0.57 0.040 0 01 <0 1/ NW 620 0.29 0.003 0.29 0.23 NE 1050 0.B1 0.033 0.84 0.1 / SW 1150 0.67 0.020 0.69 0. 79 NW 1220 0.56 0.034 0.59 0.1 7 NE 1500 0.24 0.053 0.29 0.1 / E 1620 0.22 <0.001 0.2? 0.1 7 NW 1900 1.8 <0.001 1.8 o.;m A B 05.... 30 5C Tu.' Figure 3. Typical chromatograms ol standard PCP s and soil sample taken in vicinity ol investment casting lurility in Chicago, ill (A)Fenelor OK, (D) Aroelor 1?S0. (C) soli exiract VolOme to. Numhot t3 December 1976 1231 HONS 0 8 5 8 5 5 Plpure 4. Chuxrvaiopiam o( Arocior 5460 nod soil sampt* taken in vi cinity oi investment casting lacilily in Chicago. (II. (A> AM* MOD. fli) anil inifHct mowing ptaaencc oi (1) PCO'a. (2) (WcacidoroMplwmyi. end (3M*C.T'a Table III. Results of Analysis of Soil Sample* Taken in Vicinity of Investment Casting Facility in Suburban Detroit, Mich. Direction Di*lnci> fipm Item faciirtv. facility m ----- ----------------- --------------- Aroeioi 12C0 Arocior 5460 SI. 60 NW 60 NW GO NW ?00 Si 520 NW 800 ni: 900 St 900 NW 1000 SW 1050 SW 1060 NW 1360 SL 1500 t: 1650 NI 2100 5W 2100 1 A'clo }?**. 0.04 0.12 0.07 <0.01 0.05 <0.01 0.1 4 0.06 0,1? 003 <0.01 003 0.04 18* <0.01 0.02 <0.17 <0.17 0.64 <0.17 <0.17 <0.17 <0.17 <0.17 <0.17 <0.17 <0.17 <0.1 / <0.17 <0.17 <0.1 7 <0.17 is the facility surveyed. Arocior 1260 has not, in fact. been reported to have been used by this company. The apati/il distribution of both decarblonibipbonvl anil PCT do indicate higher anil borne concentration* near the investment casting facility with generally decreasing levels at increased distance*. There exists a strong sia( isijca] cor relation among the data for deeachlorobiphcnyi and the 1** T (Aroelor 5460) und little correlation between Arocior 1260 mid decachlorobipheny! or the PCT. Again, ns at the production facility, the spatial (list rihul ion of the PCB and the PCI' present it indicative of airborne transport. The Arocior 12G0 detected ia Apparent lv not from the source surveyed, whereas decacWorobiphcnvi and IT T are hkciy from this user. It is somewhat surprising loser evi dence of significant airlmrm* transport of the higher sub.-,n luted and less volatile PCH isomers and of P( "1". That t he g;e chromatographic elution pattern show* little evidence of ei thcr selective emission or selective transport of the (non volatile isomers would indicate the source of the nirixinu contamination is at such a fcmprralurc thnt the entire l`('H or PCT mixture is in the vapor state at the point of enns sion. Investment Casting Pucility, Troy, Mich. This facility is located in a small industrial park in sulnirhiin Decruil, Mu b Surroundings consist principally of other small industries and residential areas. It has ireen reported thnt this company purchase* the wax materia) used in the casting process from the company located in Chicago which is discussed nlxwu. Tin analytical result* of soil samples taken nt tins inention are summarized in Table 111. Arocloi 12GO is detectable io most of the soil r.atuples. 1 H cachlorohiphenyl is ahs(-nt in the soils. PCT's htc present in one sample taken 60 in nort hwest of thr usei No spat ltd dis tribulion pat tern of 1*03 or PCT is evident The one observed concentration of IB ppm Arocior 1242 appears to lx uiioimo lously high. Hoplicate analysis, however, yielded similar v.du , for tins sample. Arocior 1242 was not defect'd in any other -<l samples from this area. A druinage ditch passes adjacent to the north I>uihI ii \ <>l the industrial park in which the facility is located Tindrainage ditch serves to remove stormwater runoff in the \ > dnity and receives discharged cooling water from several local amatl industries including (lie one surveyed. Analyses of coaling water at the pomf ot discharge. of water and sediment* within the drainage ditch, unit <>r water >ni sludge deposits within the sanitary sewer system serving the area are reported in Table IV. It is apparent from these d.u . that discharged.moling seniors and waters in the drnmo ditch at the lime of sampling were free l both I'CH's and PCI 's. Bottom sediments witliin tlx* drainage ditch. howeu i. contained significant concentralimis of Arocior )24J. Ana I. 1260, dccachlorobipltenyl. and Arocior MGU The source of ih contamination of ditch sediments may he attributed i HOMS 0 8 5 8 5 6 Table IV. Results of Analysis of Various Samples Tsken in Vicinity of Investment Casting Facility in Suburban Detroit, Mich. Sample Aroetor 1242 Arocior 1260 Dacachlorobiphenyl Cooling water discharge DiAinaw watci ` Drainage walei Ditch sediment Ditch Mrtimenl Sanitary sawer water 1530. 2/22/75 Sanitary sewer water IBIS, 2/22/75 Sanitary sewet water 1145, 2/23/75 Sanitaiy sewer sludge deposits <0.1 pg/t. <0.1 pq/l. <0.1 P9/J. 2.3 ppm 9.4 ppm <0.1 pg/l. <0.1 pg/l. <0.1 yg/l. <0,01 ppm <0.1 yg/h <0.1 pq/l. <0.1 yg/h 6.7 ppm 8.9 ppm <0.J un/t. <0.1 yg/l. 7.0 yg/l. 0.11 ppm <0.01 yg/l. <0.01 yg/l. <0.01 yg/l. 0.09 ppm 0.11 ppm <0.01 yg/1. <0.01 yg/l. 41 yg/t. 0.034 ppm Aroclur S460 <0 1 pi|/l. < 0 I |iy/t <0.1 yj/i 6.7 ppm 5 i ppm < 0 1 yo/1 <0J yy/t. 7.6 yn/f 5,0 ppm wastewater discharges, sometime previous to the time of wiinplitii;, or to surface runoff m the vicinity. Witter and bottom sludge samples were taken from the sanitary hewer system serving the industrial park. Grab samples of the wuter were taken three limes from a manhole access. As shown in Tabic IV, PCM'itand POT'a were not de tected in waters sampled at 1530 and lHIft, hut when sampled at 114f> the following day. POM's and POTY. wer present at a concent rat ion of II.) and 7.6 ag/)., rmtimciively. Sludge de posits within the sewer contained 0.14 ppm PCB and 6.0 ppm PCT on n dry weight basis. It appears that intermittent dis charge of both PCB And PCT to the san'ilarv sewer system is occurring. ('(inclusions PCM contamination of the environment ban occurred near the domestic production facility arid two user facilities. The spatial distribution of soil contamination suggests airborne transport of the contaminant from the manufacturer and one of thr two users surveyed. At the manufacturing site, Aroclor 1200 nnd decachlorohipheny) were distributed in such a manner its to indicate the production facility to lie the source. In urlian Chicago, decachlorobiplirnyl and POT contamina tion appears to he superimposed on a rather random hackground of Aroclor 1200 contamination in such a manner to suggest the imestineul casting facility is the source of the denirliloroliiplicuvl and (he PCT, but not the Aroelnr 1200. in suburban 1 >c(roit, tile back ground soil level of Aroclor 1260 shows luidiHirihutioii pattern that would indicate the source to he the facility surveyed. Inlluent and effluent wastewater samples from Sauget, 11)., nltesl to the removal, albeit incomplete, of POU in the bio logit al wusle treatment system. Water and sediment samples from the suimilum Detroit location indicate PCM and PCT discharges or contaminated runoff into surface drainagcwnvs sometime in the past. Discharges u> the sanitary sewer system are apparently continuing. Voluntary control on the release of PCH's nnd PCT's to I hr environment by industrial sources cannot be considered cn tirely effective. It i6 not possible to determine from soil con tamination levels at the manufacturing site, whether or not the contamination has occurred since voluntary ront rois have been instituted (cn. 1970). At the urban Chicago location, however, it appears soil contamination has occurred since 1972 when Fenclor I)K came into use. Contamination of wnstc waters is still evident. Literature Cited (1) Selikoff, Rd., Environ Hex., 6, ,1 (1072). (2) U.8. Government Interdepartmental Task Force on PCJVs. `TCB'sand the Environment''. NT1S Documeni COM-72 lo-tie. 1972. (31 Hulainger, O.. Safe. S.. Zitkn. V.. `"Hie Chemistry of PCHV. ('PC Press, Cleveland, Ohio. 1974. (4) Environmental Protection Agency. "Analysis of Pesticide Itrsi dues in Human nnd Environmental Samples". Pesticides and Tom Substances Effect* laboratory, Research Triangle Park, N ( . 1974 (5) Environmental Protection Agency, "Method for Polychlorinated Riphenvls (PCH's) in Industrial Effluents". NKItC. Gimiminti. Ohio. 1973. (6) Snyder, I)., Heincrt, R., Hull Environ Contain Toxicol, 6, (197)). (7) Murphy, P. G.. J Ax*or Off Anal ( hem55, f> (1973) (8) Pa|iageorgr. W. It.. Monsanto InriuMrint ChrmtiHl* Co , Si Laos. Mo., private communication, 1975. Krveived for review March 4, JU7(i Aucptrd June 3, I97li It'ioA conducted under Hrojcrt 6H 0I 2H7S with the Eni tnmmeiuut I'm lection Agency Offne of To.\ii Substances Vincent J He! 'urh>.< hv I Monitoring ond Information System* liranrh, served as iirojei t j ficer. rseseo snow Use of Permeation Tubes for Calibration of Vinyl Chloride Analyses William R. Burg*, Sholton R. Birch, John E. Cuddaback, and Bernard E. Sallzman Dopmtmont of hnviionmental Hoalth, University of Cincinnati, Cincinnati, Ohio 45267 A study wtik conducted to determine the performance of vinyl chioritle j>rrmrotion lubes when used to prepare lowlevel gaseous calibrat ion standards which are convenient for (he analysis of samples in t he gas or liquid phase. Permeation rates were determined gnivimctrically at three temperatures including extended periods at 25 C. The rates at 25 *C for FKP and TEE Teflon tubes (0.250 in. o.d. X 0.030 in. wall thickness) wore, respectively, 0.269 nnd 1.98 jig/cm min, and the activation energies of permeation were determined to l>e lit.(I nnd l).P krnl/g mol. Gas sHinplos prepared in a flow dilution system containing n permeation lube were used to calibrate u gas chromatograph equipped with it gas sampling valve, Calibration data, ucniracv. and limit of detection are presented. Although the permeation lubes were convenient, IHTiodic weighing is recommended for highest accuracy since slight Iv decreasing rates were observed in four tubes and some polymerization of I lie reservoir liquid occurred in one lube. Recent, recognition of the carcinogenic hazards associated with vinyl chloride exposure generated the need to monitor low levels in work areas and ambient air. The federal Occu pational Safely and Health Administration set an omipa tional exposure limit of 1 ppm for an 8-h time-weighted .iv erage with a ceiling of 5 ppm for a period not exceeding 15 mm (/). An "action level" of 0.5 ppm and above was established for employers for implementing certain required roniml procedures. Because of important economic and legal mipli cat ions, accurate analysis of airborne vinyl chloride is essen tia). The Environmental Protection Agency recently published a tentative method of analysis for ambient air concent m in ms (2), similar to that recommended by the National Iiimmuu Tor Occupational Safely and Health for occupational ureas Cl). Moth methods were based on adsorption of vinyl chloride on charcoal and desorption into carbon disulfide followed hv g;i> chromatographic determination using a flame ionization de lector. The accuracy of the method was thus dependent upon Volume 10, Xhanber 13 December 1970 1233