Document 06deZqB3q4Br1y1VeGq7XqM1R
CELANESE CHEMICAL COMPANY BAY CITY PLANT
TO: AS LISTED FROM: C. J. DUEY
CJD-132-73
MARCH 2, 1973
SUBJECT: OSHA VISIT AT BAY CITY PLANT
On January 23 ana 24, 1973, an OSHA Inspector and an OSHA Industrial Hygienist came to make measurements at the Bay City Plant. The visit was the result of an employee's complaint to OSHA. The employee said that he was exposed to excessive copper chromite dust and filter aid dust while working in me Hydrcc.enclys is Unit catalyst handling area. He also said that he was exposed to NOg blowing into his work area from the Adipic Acid and Nitric Acid Units. The OSHA team iimited their measurements to the specific items of the come Iaint.
Dust Measurements
A MSA Gravimetric Dust Sampler was used by OSHA for measuring the dust breathed by an employee. The equipment consists of a cyclone, a filter, and a rechargeable battery operated pump. The cyclone and dust filter are attached to the employee's collar and the pump is attached to his belt loop. Incoming air passes through the cyclone which removes non-resolrable dust (>I0 microns diameter). The filter traps the resolrable dust. Both respirable and non-respirable dust can be determined by weight. The OSHA Hygienist said he was sending the filters to an HEW Laboratory to determine copper and chrome content.
At least one of the OSHA team stayed with the employee at all times to make sure that he did not deliverately get dust in the filter. The pump flow was freauently re-adjusted to keep it at the calibrated flow (1.7 l/min). The pump will operate for eight hours from one battery charge.
The 3ay City Laboratory has since purchased a MSA Dust Sampling kit so that we can get measurements comparable to OSHA.
Vapor Samp Iing
The OSHA Hygienist used MSA vapor detection tubes for NOg measurements. He said that the Japanese (Kitagawa) and German (Urager) tubes were also accept able. Samples were taken in the working area of the employee. Mo NO2 was detected there. The OSHA inspectors asked to go to the Adipic and Nitric Acid Units so they could take samples for NO2 close to any possible sources.
006036
CJO-!32-73
I
\
\ March 2, 1973
Their send Inc procedure was tc go with the outside- operator on his normal samele catching round. Air samples were taken near each pump where the operator stepped to catch his samples. The air samoles were always taken near the spot where the operator would be breathing. All the samoles taken showed that we were in compliance for HO2 vapors.
SideIights
The OSHA team was very professional in their measurements and other asoects of their business. They seemed favorably Impressed that v/e had a written document showing our dust measurements in this area. Possibly, this influ enced them not to make a more extensive inspection of the area.
It is worth mentioning that the employee's complaint apparently occurred shorriv after the Laboratory samoled this area for dust. A little special handling might prevent a complaint from an embittered emoloyee or a hypo chondriac. I would recomment that care be taken not to alarm an employee when measurements are taken to check forcompiiance with OSHA regulations, it should be explained to him what is being measured and that the measurements are being made to see if we have 2 problem. He should be told the results of the tests as soon as they are available.
rx Qiu,,
C. J //Duey U
7~
mf f
Oistribution
Messrs. Centra
8.-' A. Me 1 aas K. A. Dunn L. E. Hackfe1d F. T. Talbert R. G. Brandt J. W. Corley R. M. Guedin W. H. Tuke J. M. Ramey J. E. Sanborn Fi les (2)
3ishop Clear Lake Onr'-rr'
I kb
Pampa NYQ Houston GATX TerminaI
CCCTC
File: 71
006037