Document 06a35n9nVB4Y7vV4K6x9XjM3M
Heating Systems Bomen, gs
The Webster Engineering Company
115 South Frisco St., P.O. Box 2168 Tulsa, Oklahoma Division of
SURFACE COMBUSTION CORPORATION, TOLEDO, OHIO
FOR STEEL FIREBOX, SECTIONAL, WATER TUBE and HRT BOILERS
SERIES F600
It is suitable for firing Water Tube and
Low Pressure Gas
This is an outstanding vertical atmos pheric venturi gas burner, with the radiant refractory top that utilizes straight natural gas and mixed gas to 800 Btu at pressures from 3'w.c. to 8 ounces. Series F600 Burner Assemblies are available with ratings from 50,000 to 10,000,000 Btu/hr for firing all types of steel firebox and sectional boilers.
HRT boilers and, should design condi tions prevent the use of a vertical burner
such as Series F600 or Series 650 or. the
WEBSTER KINETIC burner, the Series. 1 will prove very acceptable for firing steel firebox and sectional boilers when combustion space is not limited.
WEBSTER KINETIC* Low Pressure Gas and Standby Oil.
SERIES 200 Intermediate Pressure Gas
with Combination Oil.
Consisting of a multiplicity of full venturi mixers with flame retention noz zles assembled in a metal casing com plete with pilot and louvre, the WEB
The Series 200 Webster Radiant Com STER KINETIC burner is presented
bination Gas and Oil Burner is a straight as the latest addition to the Webster line atmospheric horizontal firing assembly of firing equipment. It may be used with
that makes it possible to utilize natural, natural, mixed and liquefied petroleum mixed or manufactured gas in combina . gases.
tion with all types of fuel oil.
Being a multiple head assembly,, the
Recommended for application to refrac tory furnaces, it is designed for firing Water Tube and HRT boilers when oil fuel is used over extended periods and a gas pressure of at least 1. lb is available.
SERIES 1A
Low Pressure Gas and Standby Oil.
WEBSTER KINETIC burner can be sup plied in any size or shape. The firing of Scotch Marine boilers with extremely low pressure gas without noise, vibration or electrical power and with minimum furnace draft was the sole objective when the WEBSTER KINETIC burner was developed. When design conditions preclude the use of a vertical burner.in
It is a 100 per cent secondary air-hor izontal firing, multi-jet burner that operates equally well with natural, mixed or manufactured gas.
a steel firebox or sectional boiler, the WEBSTER KINETIC burner is highly recommended as the next best gas appli cation.
* Trade Mark
1346
Heating Systems Burners, ou
Ace Engineering Company
1435 West 15th St., Chicago 8, 111.
'Custom Engineered Oil Burning Systems Since 1931"
The Ace Uniflow oil burner is built in ten sizes to burn all grades of fuel oil. The oil pump is available either as an integral part of the burner or as a sepa rate unit, depending upon the job re quirements. Standard models include both belt and direct drive and for opera tion with all electrical current character
istics. The Ace oil burner features as standard
equipment the patented Ace Uniflow
valve, which permits constant uniform flow and flame regardless of oil tempera
ture or viscosity. Approved by Underwriters* Labora
tories, Inc., New York- Board of Stand ards & Appeals and the States of Massa chusetts and Connecticut, these burners are designed to oil fire commercial and industrial boilers in the capacity ranges as Bhown below.
Burner Size
12 14 15 16 17 18 19 20 22 24
"TEQHNICAL DATA AND SPECIFICATIONS
Maximum G. P. H.
8 15 22 30 45 70 85 100 130 f 165
Boiler Horse Power
24 45 66 90 135 210 255 300 400 500
So. Ft. Steam Radiation
3,300 6,000 8,800 12,000 18.000 28,000 34,000 40,000 52,000 64,000
Motor Size H. P.
t
i I 1
1 1.5 2.0 3.0 5.0 5.0
ACE AIR NOZZLE
(Patent Pending)
The Ace variable-vaned air nozzle per mits accurate, efficient shaping of the flame to conform with the shape of the combustion chamber. The angle of the vanes can easily be changed in the field to any desired position to suit the boiler requirements and thus insure the maxi mum flame without oil impingement.
SEND FOR ACE MANUAL... l'P KPAItKD SPECIFICALLY FOR ARCHITECTS AND ENGINEERS.
1347