Document 06VZKJXVoyOrXBX1NpoKwyron

PLAINTIFF'S EXHIBIT NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION AIR RESOURCES MANAGEMENT PROCRAM GP-1438 APPLICATION TO CONSTRUCT OR MODIFY A SOURCE OF AIR CONTAMINATION FOR COMPLIANCE WITH 10 NYCRR 175-180 PROCESS. EXHAUST OR VENTILATING SYSTEM 1011: See form Air-100.1 for ipollution Instructions amt form Air-Si for address of field representative where application Is filed. t. DATE OF APPLICATION August 6, 1973 EMISSION SOURCE REFERENCE NO. Not Assigned APPLICANT, LEAVE BLANK 1- E- 2. APPLICANT (Firm. Municipality. School, etc.) AND MAILING ADORESS Georgia-Pacific Corporation 900 S.W. 5th Avenue Portland, Oregon 97204 3. NAME OF APPLICANT'S REPRESENTATIVE George Turner TITLE Project Engineer 4. NAME AND ADDRESS OF AUTHORIZED AGENT (If any) SUBMITTING APPLICATION: None PHONE NUMBER 503-222-5561 ATTENTION PHONE NUMBER 5. NAME OF PROFESSIONAL ENGINEER OR ARCHITECT PREPARING PUNS N.Y.S. LICENSE NUMBER Earland E. Harvey 6. LOCATION OF INSTALUTION City s Village 0 Town STREET ADDRESS Bloomingdale BUILDING Joint Cement Road Mfg. FLOOR 1 ______12250_______ CITY, VILUGE, TOWN, COUNTY Akron, Erie County DEPARTMENT Packing 7. TYPE OF INSTALUTION IF MODIFICATION, LIST NEW AND EXISTING EQUIPMENT S New Modification YES NO 8. a) HAS PREVIOUS APPLICATION FOR AIR POLLUTION CONTROL APPROVAL BEEN MADE FOR THIS INSTALLATION? b) IS THIS A RESUBMISSION OF A PLAN PREVIOUSLY DISAPPROVED? fi Enter Previous Application Number BPA-- 218-- 73 C) IS THIS A MODIFICATION OF A PLAN PREVIOUSLY APPROVED? Q Enter Previous Application No. 9. CAS CLEANING OR TREATMENT EQUIPMENT: II none, check here [j a. Type Cyclone & Baghouse b. ManulacturerCyclone S "Dustexlc. Model or Cataloi No. (Reverse Air Cleaning) 3aghouse: "Flex-Kleen" B^gAoule: ^-CT-it2 d. Size Cyc w Dia. Baghouse la. x g. Rated Overall E1mffi4cien-c3y'!- Long- e. Design Capacity or Requirement acfm 3650 Deg. f 70 h. Cost of Cleaner f. Maximum Pressure Drop 16 inches w. C. 99.9 % 10. ARE COLLECTED AIR CONTAMINATES RECYCLED OR SALVAGED? Describe recycling, salvage process or disposal method. Complete Installation: Yes [J No $20,000.00 Collected material from cyclone and baghouse is recycled to bag packer fe ed hopper via bucket elevator. 11. EXPECTED PROJECT COMPLETION DATE December 15, 1973 12. HAS APPLICANT COMPLIED WITH OTHER APPLICABLE CODES? g Yes No 13. ENUMERATE DRAWING NUMBERS OF PUNS SUBMITTED IN TRIPLICATE WITH THIS APPLICATION #40-73-1 #40-73-2 #40-73-3 #E-41-251 #7307-1 SGP 0021925 114. TYPE OF ESTABLISHMENT (Product manufactured or service rendered) (e.g. Foundry, Retail Store, Municipal, Lighting Fixtures, Toys, etc.) (Gypsum Products Manufacturer It. EMISSION BATE POTENTIAL* (The rale hi pounds per how at which air contaminants would be emitted to the outer air in the absence of air pollution control facilities or other control measures.) A. Gas and Liquid Particulates Type Quantity (Ibs/hr) Quantity (tons/yr) B. Solid Particulates Type Joint Cement Dust -- Process Weight (Total Weight of all materials introduced into a process; e.g. coke, limestone, etc.) 4 Tons per hour C. Average hours operation 20 per day 120 per week SEE PACT 187 FOR DEFINITIONS AND AFPLICAIIUTY 17. A. Proposed or Certified Environmental Rating (for process, exhaust or 8. If Environmental Rating has been certified, enter here ventilation system applicable under Part 187) E- 18. EMISSIONS (Actual) A. Caseous Not applic:able Material Quantity (Ib/hr) Stack Concentration PPM B. Particulates Materia! Joint Cement Dust Quantity (Ib/hr) 0.04 Undiluted Exhaust Gas (Ib/IOOOtb) Not applicable 19. POINT OF DISCHARGE A. Location Through Wall D. Horizontal distance to nearest bldg beyond property line cjqq p-j. G. Exit gas or air temperature (*F) 70 20. FUEL USED IN PROCESS "None" A. Coal-Type Ibs/hr 8. Height (ft above ground) 14' 6" E. Exit inside dimensions (inches) 12 x 13V H. Air or gas flow rate (CFM) 3225 X Sulfur by Weight C. Elevation at ground level p 686 Ft. F. Exit gas or air velocity (ft per minute) 1. Draft 3500 Q Natural 3 Mechanical 8. Oil-Grade GPH X Sulfur by Weight rr^- C. Cas-Type Cu ft/hr SIGNATURE OF INDIVIDUAL OR OFFICIAL George Turner TITLE / N '' ' /" ' Project Engineer Q- -X Any person knowingly making any faTse statement or false report in connection with this application shall be liable fprj'penalties os prescribed by law. f3 _ . ' ' I, ' /" jirrv'V/ SGP 0021926 U C JLttl O C MAWnmc^ **nu i iuiij r utmim i wn < Wtnj. .fc. *- mvi v> SHEET, FORM IH-212.1 FOR GUIDANCE IN THE PREPARATION OF EXHAUST SYSTEM PLANS. )tm CLEANING DATA 1,8. IS AIR CLEANING EQUIPMENT PROVIDED? lffTYPE^jFAn^LEANINtffQUtPMENT (H any) TO BE USED fCrcfon*. Clolft An..tor. F.le.i dVES NO Cyclone and Baghouse (Reverse Air Cleaning)________ 2C*. /UR CLEANER MANUFACTURER _ Cyclone: Dustex, Inc. Baghoasej--F3 ex-Kleen,--Inc AX1MUM pressure drop through air CLEANER AT OPERATING CONDITIONS f'tF.G.J __ J0t>. MOD EL.OR CATALOG Cyclone: 28-100S-32 Bacrhouse: 84-CT-54 Cyclone : 5 " BaqhOUSe2 7" 20c. SIZE Cyclone: 2*8" Dia. x 81 Q" Long._ Baghouse: 6'0" Dia. 14'3" Loner rAN DATA flf more than one fan system is shown on plans, each fan should be numbered and described) 12. FAN NO. 23. MFR.'S NAME 10| New York Blower ;4. MFR.'S RATING: RPM CFM FAN TVPE DESICN Co, Centrifugal______________ Material Handling192 S.P. fin. waft) B.H.P. MOTOR H.P. 25. fan condition SIZE 3130 3650 :6. DESIGN REQUIREMENTS: CFM 3225 16" S.P. fin. water/ 14" 15.9 20 27. FAN INLET DIAMETER 12 inches PC I New 1 1 Reconditioned j \ EsUting 28. FAN OUTLET DIAMETER OR SIZE 12 X 13*5 Inch.* )LMENS10NS Of UNITS EXHAUSTED (Identify on plan by letter; use separate sheet if necessary) T Ai f AN ^Y^Tr--, 111~^K' c*r'i n y SGP 0021927 ~ ATE DEPARTMENT of labor ''.Division of Industrial Hygiene Engineering Section / f\r r i ft wit r vr\ nr r i\utal wr EXHAUST SYSTEM PLAN linis oox roc ctuce use vu; PLAN NO. DATE REC'D. FEE REC'D. // FILING INSTRUCTIONS - ONE COMPLETED COPY OF THIS FORM MUST BE FILED FOR EACH FAN SYSTEM IN THE EXHAUST PLANS BEING SUBMITTED. Forward exhaust system plans IN TRIPLICATE, together with one completed copy of this form for each fan system, to the Engineering Section of the Division of Industrial Hygiene at one of the following Department of Labor Offices. Plans for exhaust systems to be installed in the counties of CaVaraugus, Chautauqua, Erie, Genesee, Livingston, Monroe, Niagara, Ontario, Orleans, Wayne, Wyoming and Yates should be sent to: 2447 SHERIDAN DRIVE, TONAWANDA, N.Y. 14150. Plans for exhaust systems to be installed in counties other than those listed above, should be submitted to: 80 CENTRE STREET, NEW YORK, N.Y. 10013. IMPORTANT: Effective June 1, 1963, the Industrial Commissioner is required by section 204-a of the Labor Law to charge a FEE FOR THE EXAMINATION OF EXHAUST PLANS. Please forward with the plans a check or money order payable to the Industrial Commissioner, in accordance with the following fee schedule FOR EACH FAN SYSTEM: CATEGORY A CATEGORY B "Simple single booths and enclosures, such as spray booths; canopy All systems other than category A. hoods; dilution, general and natural draft ventilation systems'*. Design CFM Fee Design CFM Fee less than 250 250 or more but less than 1,000 $10 20 less that 5,000 5,000 or more $10 20 1,000 or more but less than 5,000 5,000 or more but less than 10,000 10,000 or more 30 40 50 1. FIRM NAME Georgia-Pacific Corporation_______________________________________ 2. MAILING ADDRESS 900 S.W. 5th Avenue, Portland, Oregon 97204 3. PLANT LOCATION and Number, City, Tosvn, Viliaga; County) Bloomingdale Road, Akron, Erie County, New York 14001 4*. PLANT REPRESENTATIVE TO BE CONTACTED REGARDING EXHAUST SYSTEM PLANS 4b. TITLE George Turner Project Engineer 5. NUMBER OF IN-PLANT EMPLOYEES AT THE ABOVE PLANT LOCATION: TOTAL 135 MALE 131 FEMALE 4 6.NO. OF EMPLOYEES AT OPERATIONS OR MACHINES 70 7. AUTHORIZED AGENT (il anr) SUBMITTING PLANS (Ena-. Daaign.r, Coniultma Finn, Ele.J LETTER OF AUTHORIZATION MUST ACCOMPANY PLANS None 8. BUSINESS ADDRESS OF AGENT 9. NO. OF FAN SYSTEMS SHOWN ON PLAN (Fan Syatama Should Ba Numbarad) One (1) 10. SUBMITTED FOR COMPLIANCE WITH INDUSTRIAL CODE RULE NO. 10NYCRR--80 general data FAN SYSTEM NO 10 AMOUNT OF FEE FNC1 Q<sFO * $30.00 previously sent for this system 11. LOCATION OF SYSTEM .. building Joint Cement Manufacturing None * b. floor one ssssai Bage. department Packing 12a. IS PROPOSED INSTALLATION NEW? SI YES HO d. NUMBER OF FLOORS IN BLDG. One 12b. ADDITION TO OR RECONSTRUCTION OF EXISTING SYSTEM YES HN0 13. DOES THIS PLAN AMEND lei YES PREVIOUSLY SUDMITTED PLAN? ' ' 'NO 11 IF YES. GIVE PREVIOUS PLAN NO. AND AMOUNT OF FEE PAID BPA-218-73 ($30.00) 14. IS THIS INSTALLATION TO COMPLY WITH ORDERS OR SPECIFIC RECOMMENDATIONS ISSUED BY THIS DEPARTMENT? HYES ___ aN0 IF YES. GIVE DATE OF ISSUANCE October 27, 1972 15. IS DISCHARGE OF SYSTEM TO BE RECIRCULATED TO THE WORKROOM' ,___ | YES ,_X NO (**DI achargad Air HhfcA Conlg/na Danjareua Air Contamlnanla Shall Sot Ba Racirculatad.** Ruta t$~S.S) 1* "MSCHARGE POINT: |___ | ABOVE ROOF j___ |oUT OF WINDOW [2S THROUGH SIDE WALL |___ | OTHER 20 FEET TO NEAREST FIRE ESCAPE OR EXIT XKMOCCX3CJCXBC 5 FEET TO NEAREST WINDOW 17. MAKE-UP AIP, EQUAL IN VOLUME TO THAT EXHAUSTED. TO DE SUPPLIED BY Natural Draft 17a. MEANS FOR HEATING MAKE-UP AIR None SGP 0021928 . 1 I NEW YORK STATE DEPARTMENT OF ENVIRONMENTAL CONSERVATION DIVISION OF AIR RESOURCES BUREAU OF AIR QUALITY CONTROL 41 STATE STREET ALBANY, NEW YORK 12207 ENVIRONMENTAL ANALYSIS REPORT - SUMMARY OF SOURCES i For completion by applicant (in triplicate) % Report _No Uce ana copy ol tbit farm o a cover cheat for each copy of the Environmental Analytic Report cubmitted in triplicate 1. Name of firm or owner , Georgia-Pacific Corporation BAQC Accign. 2. Addrecc of inttollorion , Bloomincrdale Road, Village of Akron, Erie 3. Person to contact in roforonco to this submission 4. Proposed Environmental Roting(s) E mi son Point No, Not Assigned Process, Exhaust or ______Ventilating System_________ Bag Packer, Joint Cement Manufacture ing Georae Turner. Project Engineer Nome 9Q0 s.W. 5th Avenue Portland, Oregon 97204 Address Proposed Env. Rot. Emission Point No. Process* Exhaust or Ventilating System Proposed Env, Rot. Continue on reverse side for listing of proposed ER*s. ' 5. Dot, Aligned fi, lq7lA. Signature ^^ 1 ^________ 7. Title____PTQ jRCt, -Eng 1 QP.ar f. 0t 9. Signature __________________ 10 Title SGP 0021930