Document 06KvmRNpE63EG4k98p8z8r83k
FILE NAME DuPont DUP
DATE 1968 May
DOC DUP061
DOCUMENT DESCRIPTION Industry Testing Procedures - Adrian L. Lynch Operation of the Model 440 Uncio Mighty Asbestos Dust Sampler
SPERATION OF THE MODEL 440 UNICO MIGHTY ASBESTOS DUST SAMPLER
Adrian L. Linch
May 1968
I. Prepare Filter
A. Remove plug from filter deck end and attach the open tubulature to the gum rubber sampling hose Slight moistening of the plastic tubulature assists with hose attachment Excessive moistening will cause hose to immediately slip off
B. Remove the top uppermost section of the filter assembly
without disturbing the reel of the center ring against the filter paper on the filter support deck Do not remove the plug from this top section at any time before attachment of the sampling hose in preparation for sample collection
C. After the sampling has been completed replace the top section with plug in place and seal securely Tape the plugs in place by passing tape around the unit axially several times under slight tension Any adhesive
tape will serve
D. Identify each plastic filter case by applying a label containing the site serial number and date sample was taken Label to be applied on filter case shelf for protection in Handling
E. E. Wrap the filter unit in paper toweling or other bulky paper packing and place in the mailing container
5 . Do not attempt under any circumstances to remove or replace the filter membrane or use a filter which has been exposed by either plug becoming dislodged or by separation of either assembly member before use The background blank supplied with each lot of filters is valid only for sealed sampling units
II
Prepare Mighty Air Sampler
A. Insert a fully charged battery into the bracket located on the inside of the front panel
1. Make sure the positive + pole is in contact with the positive contact of the bracket Although the principle will operate on reversed polarity excessive
strain and wear will soon destroy the pump assembly
061380
061380
061380
061380 0601613380 80 061380 061380
061380 061380
DUST SAMPLING PROGRAM
A
I. Air Analysis
1. Work environment evaluation - Consider not only insulation installation exposure but also dismantling work grinding metals and cutting other materials welding etc.
Insulation exposure to be applied first week of each month If results indicate improvement required after correction is made a second proof sample must be made within that
specific month
Selection of participant employee - Safety Engineer with the Craft Superintendent and Craft Foreman will select the participant This should be based on that individual
employee's work assignment for the day of sampling
It is expected that the employee subjected to the most severe exposure in producing dust from the varied work assignments
will be selected
Introduction to employee wearing the instrument making air
sample - Example of approach For your protection we are
interested in continuing to control the amount of dust in the air We are requesting your participation by wearing
this dust measuring instrument while you are working today
It will not interfere with your movements and there are
no adjustments that you will have to make
Special dust problems - prior to
Division Safety Office This is
can be made on sample submitted
"
samples a month
collecting contact to assure that analysis
We are limited to 30
II Use of Instrument
instrument 1 Instrument is assigned to you Safety Engineer trained and
qualified in operation of
and you are held
responsible for condition of instrument application of
instrument recording technical data mailing sample
and compiling results at site location
Preventive maintenance and calibration will be
performed by Adrian Linch Medical Section Chambers Works Frequency for calibration will be determined
by Mr. Linch
Work Sheet - This is made out in triplicate 3 copies
One carbon is to be retained at site and original and one carbon copy are to be submitted with sample plastic holder to Mr. Stein University of Pittsburgh
gd
OVER
II
Prepare Mighty Air Sampler continued
2 If the pump fails to start when the rheostat is
advanced from the on position check the battery
contacts for open circuit due to distortion or
bending of the bracket
Failure to start also may be due to a discharged battery
a Neglecting to recharge after last use
b Accidentally discharged - rheostat left in the on position
c Dead battery - not rechargeable - return for repair
d Fault in the charger see charger instructions
e Check by replacing the dead battery with a freshly charged unit
4 If a hum is heard but air is not drawn through the rotameter the motor linkage has failed return for repair
B. Install the clothing clip just under the filter unit
C. Attach the open end of the sampling hose to the right hand
500-1500 min range rotameter tubulature Again moistening the bore of the hose will facilitate assembly
1. The plug must be securely in place at all times in
the left hand LPM rotameter Leakage at this point may prevent drawing sufficient air through the right hand rotameter and will rapidly consume the charge in the battery and reduce sampling time
III
2
Install the Assembly
A. Pass the wearer's trouser belt through the loops provided in the rear of the Unico Mighty air sampler
1 The selection of location is up to the discretion of
the wearer unless the job assignment will determine the location In any event locate in a position which will least interfere with the employee's work
motions and which will involve the least potential damage to the sampler unit
001891
001891
-II
Install the Assembly continued
B. Attach the filter unit to the wearer's clothasicn log se as practical to his breathing zone by means of the fabric
clip If the air sampler is worn in back the sampling hose should be brought up over either the right or left
shoulder
1. Adjust hose length position and attachment to the
clothing to eliminate loops which may catch on pro-
-
truding objects in the work environment Extra loops
to further secure the hose can be fabricated quickly
from adhesive tape and attached to the clothing
with safety pins
IV
Sampling
A.
Advance the rheostat on the right lower corner of the Unico
Mighty until the rotameter indicates 1200 CC13
1200 min = 1.2 LPM = 0.0424 ft.= 2.54 CC13 or the calibration valve equivalent to 1200 min see
calibration furnished
1. The rotameter is calibrated to read the bottom of the floor
2 Failure to attain required pumping rate may be due to
a Forgetting to remove top of filter unit to expose
the filter
b Insufficient charge in the battery
C. Obstruction in the sample hose
d Malfunction in the pump itself - worn piston or valves >>> foreign material producing a binding action
keep solvents and liquid chemicals out of this pump )
Return to Construction Division Safety Office for
repair
e Obstruction in the rotameter > the left hand rotameter
can be used if a calibration is available
The rotameter can be cleaned by removing the
top retaining stud great care must be exercised
to avoid loss of the stainless steel float and swabbing with a pipe cleaner dipped in Xylene However this is not a recommended field repair return to headquarters for repairs unless an emergency requires immediate action
0000 112299220 1292
Sampling continued
B. Record the time at start If for any reason sampling is
interrupted record the stop and restart times as the
time calculate total running
is required to
size 0.0424 ft.x minutes = ft.
the sample = sample size
Check the sampling rate at least once every hour and adjust the rheostat to provide the required sampling
rate if necessary Record the rate found if different than
the calibrated value requiretdo correct the sample
volume
Ambient temperature and relative humidity should be
recorded on work sheet
Disconnect the filter and prepare
after finish of sample period
for shipping
See
C
F. Remove battery and place in charger
Battery Charger
A. Open charger case and place battery polarity - be sure the positive + the positive clip
in the bracket - observe
end is in contact with
1 Reversed polarity may cause the battery to explode
Then plug into a 110 volt AC outlet and charge at least
hours before use
Never connect the charger to the 110 volt AC circuit
without a battery in place or remove a
the charger without first disconnecting
volt AC source The rectifier elements
battery from
from the 110
will burn out
in a few minutes unless a battery is in place with the
current turned on
The batteries
fully charged
may be left on battery ceases
charge indefinitely as a to draw charging current
ee
"
SITE
WEATHER INSTRUMENT NUMBER
SAMPLE TOTAL TIME
1 PUMP RATE
DATE SAMPLED
TEMP .:
R.H
WORK LOCATION
HRS
VOL SAMPLED
CF
CF TIME
CHECKED BY
SPECIFIC PRODUCT AND MATERIAL
OPERATION VENTILATING CONTROL
DRAFTS 2 PUMP RATE
CF TIME
SPECIFIC PRODUCT AND MATERIAL
CHECKED BY
OPERATION.
VENTILATING CONTROL
DRAFTS 3 PUMP RATE
CF TIME
SPECIFIC PRODUCT AND MATERIAL
CHECKED BY
OPERATION VENTILATING CONTROL
DRAFTS 4 PUMP RATE
CF TIME
SPECIFIC PRODUCT AND MATERIAL
CHECKED BY
OPERATION
_
VENTILATING CONTROL
DRAFTS
5 PUMP RATE
CF TIME
SPECIFIC PRODUCT AND MATERIAL
CHECKED BY
OPERATION VENTILATING CONTROL
DRAFTS:
001294
01294