Document 06Gm5d56xjjL6g5GDXzZpoZxn

; ' . , -V f " ,'u . -i-. `..v* ..... -- *. - ;= * . r- . '* $*'9v > .*. s$.. . . yl --... .. HOT STRIP MILL SPECIFICATION No. 7lU8(3-U) ACOUSTICAL CEILING m PREPAREDi'BY - VV-T A-vr .. ,?.v '' KAISER KEN 005290 INTER-OFFICE MEMORANDUM D. R. McSparrin Construction, Middletown DATE FROM April 6, 1966 W. L. Hick copies to See Distribution AT Middletown JOB NO. 7148.221 subject Hot Strip Mill Acoustical Ceiling Attached are one (l) cover bound and seven (7) unbound copies of Specification No. 7148(3-4) Acoustical Ceiling, dated March 15, 1966 for your preparation of a subcontract package. JBC/ls Attach. cc: Armco P. R. Smith * F. W. Barnes * T. R. Foley * Reading File Kaiser M. Janner * E. J. Denner L. H. Kash V. L. Frankson Central File * Reading File * Bound copies attached. . . \ : \v ' KEN 005291 HOT STRIP MILL SPECIFICATION No. 7148(3-4) ACOUSTICAL CEILING FOR MIDDLETOWN WORKS EXPANSION PROffiAM ARMCO STEEL CORPORATION MIDDLETOWN, OHIO PROJECT No. 7148 APPROVED FOR CONSTRUCTION DATE KEN 005292 KEN 005289 Spec. 7148(3-4) Hot S trip M ill 6471 A coustical C e ilin g 1 s V acoustical ceiling 1.0 SCOPE or work Work covered "by this Specification shall include the materials and the application of acoustical ceilings indicated on the drawings and/or as specified herein, including suspension system. 2.0 INSPECTION All associated work by others shall be examined, and any defects shall be reported in writing prior to proceeding with the Work herein. Starting of the Work shall constitute acceptance of the work-by others. 3.0 COORDINATION To permit orderly and expeditious procedure of the Work of this Specifi cation, the applicator of acoustical ceiling shall consult and cooperate with trades whose work precedes and follows acoustical installation. 4.0 MATERIALS 4.1 Acoustical Panels - Lay-in type shall meet the requirements of Federal Specification SS-A-ll8b, and ahaiT be Class A non-combus tible as tested and reported by the Acoustic Materials Association* flame spread rating ASIK E 84 - AMA Class I (0-25). They shall hare a noise-reduction coefficient of mere than .65, and a light reflect ance *&' of over 75^* thickness and size of units, design and? face edges shall be as indicated on the drawings. Color shall be white; pattern shall be as selected. Sizes of panels shall be 24" x 48" x a minimum of 5/8" thick. Panels shall he equal to that as manufactured by The Celotex Corporation, National Gypsum Company, Armstrong Cork Company, and Owens-Coming Fiberglas Corporation. 4.2 Suspension System - The suspension system for supporting the lay-in type panels shall be a T and T system. T runners and T splines shall be heavy duty type with exposed surfaces finished with factory applied white baked on enamel. 5.0 INSTALLATION 5.1 Suspension system shall he installed as shown on the drawings or directed by the manufacturer on approved shop drawings, and shall be. leveled before panels are installed. 5.2 T rttmers shall be installed on 48" centers by means of wire or steel stEfiipr hangers. T splines shall be supported off of the T runners on 24* centers. All T runners and T splines shall he straight in align ment and flush at all intersections. The assembled grid shall be leveled to within l/8" in 12". A metal edge moulding (same finish as T shapes) shall he Installed wherever the suspended grid abuts walls, columns or any other vertical surface. **** Page 1 of 1 KEN 005293 Design Drawings Number 601119 601122 601123 601124 601125 601126 601127 6OH36 601146 601147 601148 601149 601151 601157 ACOUSTICAL CEILING SPECIFICATION NO. 7148(3-4) 1 Title Coiler Pulpit and Director Room Plans, Elevations & Details Finishing Mill Pulpit and Mill Office Complex - Elevation Finishing Mill Pulpit and Mill Office Complex - Sections & Details Finishing Mill Pulpit and Mill Office Complex - Sections & Details Finishing Mill Pulpit and Mill Office Complex - Sections & Details Schedule and Operating Office Complex Plans & Elevations ? ?i* Schedule and Operating Office Complex . Sections & Details Room Finish Schedule Roughing Pulpit No. 2 and Malnt. Shop Elevations Roughing Pulpit No. 2 and Malnt. Shop Building Sections & Details . Roughing Pulpit No. 2 and Malnt. Shop Miscellaneous Details Roughing Pulpit No. 2 and Malnt. Shop Miscellaneous Details Roughing Pulpit No. 6 - Plana ti Details Finishing Mill - Reflected Ceiling- PHuts Page 1 of 1 KEN 005294