Document 0659r4BMRNmYz422DzZKO6oQd
Monsanto
TO :
E| E> stewart, W. G. Kruinmrlch Plant
July 31, 1972
POLYCHLORINATED BIPHENYLS AND THE ENVIRONMENT
Mr, Paul Heisler Director of Environmental
Control at W.G.K.
cc 0. L. Bratoch W. C. Engman G. A. Hippe
P. B. Hodges - 0.0. (E1SF) A. E. Leisy
W. B. Papageorge - 0.0. (B2NA) J. R. Savage - G.O. (B2SL)
During the paBt three years, varied actions have been
Implemented at the W.G. Krummrich manufacturing facilities to restrict and reduce Polychlorinated Biphenyls (PCB) entrance into the environment.
Major activities can be summarized as follows. More details related to the specified areas are attached.
I. Hie total production of Aroclors at the W.G.K. Plant reached a peak in 1970 and has since decreased by 16$.
II. Production of the higher chlorinated homologues, (Aroclor 1248 and above) has decreased about 60$
since 1969.
III.
Manufacturing facilities were installed to produce a more biodegradable homologue in the chlorinated biphenyl series, Aroclor 1016. Expect about 60% of the 1972 total production to be Aroclor 1016. ($970,000)
XV. Container alterations made (heavier metal drums).
V. Product labeling changes were made to reflect possi bilities of environmental contaminant, restrictions
for use of therminol and opportunities for waste disposal by Incineration.
VI. Installation of facilities to permit reworking and/or
incinerating PCB's returned from the customer as a
means of waste disposal.
($790,000)
VII.
Have replaced all Therminol units and hydraulic systems
outside the manufacturing department which had contained
polychlorinated biphenyls with non PCB type fluids.
($80,000)
.
HONS 042690
Mr. Paul Helsler POLYCHLORINATED BIPHENYLS AND THE ENVIRONMENT
WOK
VIII,
Equipment modifications and Installations were made to
restrict and contain knowing losses of PCB's to the lowest
technical achievable level within the manufacturing depart
ment.
($170,000)
IX. An educational program Is being directed to the operating personnel related to good housekeeping and the need for care to control and contain Aroclor wastes In the manu facturing areas.
X. Developed and Implemented automatic stream sampling stations to closely monitor the PCB content In effluent streams from the manufacturing facilities and the Incinerator area.
XI. . Laboratory equipment was purchased and plant expertise was developed to analyze streams for PCB's In the parts per billion range.
Needless to say, such activities as listed above to control and contain PCB losses, require a dynamic action control program. Many people are Involved from the operators, first line super vision and superintendents at the operating level to the
technicians, chemists and engineers In the laboratory, environ mental control and engineering departments. Total manpower requirements related specifically to the loss control program of containment and control are conservatively estimated at 20 manyears since 1969 ($400,000).
Edward E. Stewart Technical Services Department
/tm att
MONS 042691