Refine
Estimated Years 1960-1969Clear
16,810 results foundRefine Search
. v=3 fel c=a Industrial Hygiene Digest August, 1 showing evidence of pulmonary edema.
Document image
refid# 2JoEGeYqwGgQwBMmdrR6aby5L1 page
TABLE 42--B THRESHOLD LIMIT VALUES FOR 1968 (Concluded) Pentaerythntol Plaster of Pans Rouge Silicon Carbide Starch Sucrose Tin Oxide Titanium Dioxide Vegetable oil mists (except castor, cashew nut, or similar lrntant 01 Is) `When toxic impunties are not present Appendix E Some Simple Asphyxiants -- ' Inert" Cases and Vapors Acetylene Argon Ethane Ethvlene Helium Hvdrogen Methane Neon Nitrogen Nitrous Oxide Propane Requests for permission to republish or reprint these Threshold Limit Values should be directed to Secretary-Trea surer, ACCIH, 1014 Broadwav, Cincinnati, Ohio 45202 bnef excursion of concentration beyond the acceptable ceiling There are many sub stances where such excursions would be quite acceptable, if the remaining exposure is otherwise limited to the acceptable ceiling and acceptable time-weighted average The Z37 Standards also include any other level or levels considered by experts to be pertinent to a particular substance under consideration Many individuals refer to a published TLV or AC as a "go" or "no go" value -- something to be used m a specific situation --and over look the important qualifications of these values set forth by the organizations estab lishing them The preface to the annual list of TLV's and the introduction to each of the ASI Z37 series of AC's provide a basic ex planation of the concepts on which these values are based To use the values intelli gently, their definitions should be understood before they are applied to a specific situation Knowledge of the type of injury which would result from dangerous overexposure is also needed As mentioned previously, toxic effects may be broken down into four major classifications ' 1 Acute toxicity, 2 Chronic toxicity, 3 Narcosis, and 4 Discomfort The time-weighted average concentration would be the appropriate guide where chronic toxic effects result from overexposure When protection against narcosis is required, the concentration should never exceed some ceiling value To minimize discomfort, the instantaneous excursions or peak concentra tions are of interest Both the ASI and ACCIH, in defining their respective values, point out that an understanding of the criteria on which the values are established is necessary in decid ing how to use the values It should be remembered that TLV's and AC's are, even though applied as intended, relative values The concentration that just approaches the threshold limit is just as haz ardous or safe as the one that slightly exceeds it, and conversely There is no fine line that can be drawn to provide complete safety for all individuals In general, it is desirable to limit air con tamination to the lowest possible level -- consistent with efficient plant operations Probably the greatest misuse of both the TLV's and the AC's is the practice of com paring toxic substances by a ratio of their respective AC or TLV It should also be re membered that neither the TLV nor AC should be considered the sole criterion of sus pected occupational disease The ASI and ACGIH specifically state that their values are intended to serve as guides for good engi neering practice and are not intended to be 1321
Document image
refid# 7MjmprYq07n0ONoJb0pBNR20R1 page
17--Building Construction and Maintenance Fic 17-2 --Wall bracing must be adequate for anticipated wind loads This shows the result of not sup plying bracing for a partially constructed wall Lateral bracing Incomplete buildings for which designed lateral support is not yet in place, and all free standing walls should be adequately braced against the maximum anticipated wind pres sures Extenor masonry walls, especially of either load-beanng or nonload-beanng type what ever their height, are subject to wind loads be yond their designed capacity pnor to the final set of the mortar or final be into the structure These wind loads have caused walls or secbons of walls to break off and fall, causing both personal injury (somebmes fatal) and property damage See Figure 17-2 Masonry walls should follow the erection of permanently installed structural members so that adequate lateral stability is provided If this is impossible or impractical, temporary bracing should be placed until structural mem bers can be installed Usually the architect will include in his de sign pilasters as well as the requirements for anchors and ties Also local building codes 406 require that during erecbon of walls the proper bracing and supporting shall be pro vided The quesbon is, what is proper During construction of exterior masonry, two external forces should be considered--the weight (vertical) and the wind load (hori zontal) Because the vertical load is sup ported by spandrels and relieving angles, the cnbcal considerabon is the horizontal load Protecbon or bracing for this load must be pro vided either by screening or by simple shoring Codes and other engineering data indicate the thickness and height of walls which will withstand specific wind loads while unsup ported These specifications should be checked against the local wind conditions and bracing provided when required (See R W Armstrong citabon m "References ") The Nabonal Building Code (1967 Edibon) requires the following During erection, masonry walls shall not be built higher than 10 times their thickness unless adequately braced or unbl provision is made for the prompt installation of permanent bracing at
Document image
refid# Ew1JmaYBZdaMg5Kxb12JxYjL1 page
23--Sources of Help paper reproduction, is furnished on request International Association of Drilling Contractors 211 N Ervay, Suite 505, Dallas, Texas 75201 This association works to improve oil welldnlling contracting operations as a whole and to increase the value of oil well drilling as an integral part of the petroleum industry The association holds an annual safety clinic and has standing and special safety commit tees of contractor representatives to study cur rent problems Safety Hints on Drilling, an eight-page monthly periodical, gives pertinent safety information, accident case histones, and statistical data Safety clinics for tool pushers, drillers, and crewmen, sponsored by the association, are conducted throughout the country in locations where these men normally reside A Supervisory Accident Prevention Train ing Program has been developed to instruct supervisors and tool pushers m how to estab lish and maintain effective accident preven tion programs A professional safety in structor personally conducts these programs anywhere in the world where 18 to 25 people wish to enroll Each enrollee receives a specially prepared drilling safety manual Schools of either two-day or five-day duration are available Safety award certificates, cards, safety hat decals, and plaques are given to member per sonnel and ngs which have completed one or more years without a disabling injury The group has produced safety manuals for the industry, inspection reports, color codes, safety signs, studies on protective clothing, and other publications They have produced color films, film strips, and slides on spe cific drilling ng safety practices The as sociation also produces safety posters keyed to the hazards of the drilling industry International Association of Refrigerated Ware houses 7315 Wisconsin Ave NW , Washington, D C 20014 The association's Safety Committee con ducts a program specifically aimed at reducing accidents and injuries m refrigerated ware houses The program includes penodic in dustry surveys to determine types of injuries being experienced, their causes, frequency 614 and seventy, safety bulletins, posters, awards, and information on how to establish and op erate a safety program Members are encour aged to submit problems to the Safety Com mittee for study and suggested solutions Linen Supply Association of America 975 Arthur Godfrey Rd, Miami Beach, Fla 33140 The association represents approximately 95 percent of all the linen supply volume in the United States and Canada.
Document image
refid# LJMqE58wnBRG70MRex6qgJoBg1 page
May 4, 1966 Mr.
Document image
refid# xR2drjqvBggq0K4K63B30dD01 page
EDWAMD M.
Document imageDocument imageDocument imageDocument image
refid# XRGm7e5v08R58npenBa4rpODx10 pages
14 AFFMCAYIOM MCVION rtvcx 9*ak shoc mammons MODEL TRUCK toe..
Document image
refid# ZJynYgrKDYJ1EDZjz9pYXOj801 page
r 7/ 0 The prognostic value of measuring the gross linea# radial growth of pulmonary metastases and primary pulmonary cancers PLAINTIFFS exhibit The gross rates of growth ofpulmonary cancers and pulmonary metastases may be reduced to clinically useful nomograms and graphs.
Document imageDocument imageDocument imageDocument image
refid# 375v13KKr5Kag4BoRQYq7xaRa5 pages
(Q Officers S3 Malcolm F.
Document image
refid# oManZRDdqmbYZJJydgYwG7dd31 page
i&V-'-C- - '-hi- ':i BRfltCE bRUMS (Cont ) . 3 WHEREVER TWO DIFFERENT NUMBERED BOLTS AND NUTS ARE SHOWN FOR AN APPLICATION THE TOP LISTINGS ARE THE RIGHT HAND THREADS, Car & Year Models Front Drums Front Bolt Front Rear O Nut a Drums Rear i x Rear Bolt o Nut O FAIRLANE (Cont.) 1966 All Models 54, 62, 63 w/8 Cvl. 390 Eng. 1962-65 All w/10" x 2" H.D.
Document image
refid# mpnNwmNkLwa5KnM0N0QXJNV301 page
pi) BALKAMP APPLICATION CHART Make & Years Models Volts Rotation Shaft Dia.
Document image
refid# NZyaoob6yowqXQJnaekbQEoE1 page
QD) BALKAMP APPLICATION CHART Make & Years Models Volts Rotation Shaft Ola.
Document image
refid# 2jXb67qj7xvb1jg2qezqN63yb1 page
BALKAMP MOTOR MOUNTINGS I APPLICATION CHART--(continued) MAKE & YEARS MODELS CORVAIR I960 All 1961-65 F.C. only CORVETTE 1963-65 All 1955-62 All DESOTO 1960-61 All 1957-59 All (Exc.
Document image
refid# x50vO8ngbeoeNkga4vmb1mXnG1 page
Bcr/kcrmp iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiniiii STEERING IDLER ARM REPAIR KITS (Cont.)-174 Car NASH OLDSMOBILE .
Document image
refid# rpw3MgMbB51X1bonB18VprOaa1 page
fldIk. <7mp 214-CHANNELS, DIVISION BAR & CONTOUR WEATHER STRIPS (Cont.) 3-7170 INNER BELT WEATHERSTRIP APPLICATION CHART (Cont.)
Document image
refid# wDYyJ8xjy7ybJZJmaEmD46Qjo1 page