6 CHAPTER X 1957 Guide Manometer: An instrument for measuring pressures; essentially a U-tube par tially filled with a liquid, usually water, mercury, or a light oil, so constructed that the amount of displacement of the liquid indicates the pressure being exerted on the instrument.
refid# LgVQm2bRepbD3OydVzJgXQEYb1 page
232 CHAPTER 10 1957 Guide Housing and Home Finance Agency for the guidance of owners, builders, and architects.14 The dotted lines are the -- 20 F, 0 F, and +20 F isotherms of winter design temperature taken from Fig. 1, Chapter 12.
refid# gQz615z2mVp9Mz5Rq2jVmnKQ1 page
500 CHAPTER 19 1957 Guide Table 12.
refid# 0LynzaLmwK97xy9R0ZrX44NmO1 page
774 CHAPTER 30 1957 Guide outlets are attached either directly to the bottom of horizontal ducts or to special vertical take-off ducts which connect the outlet with the horizontal duct.
refid# K6K9MgB2q84mNqjRR24r6n82x1 page
792 CHAPTER 31 1957 Guide Air Duct Design 793 noted, however, that absolutely reliable dynamic loss coefficients are not yet available for all duct elements and that the infonnation available for pressure losses due to area changes is generally restricted to symmetrical area changes.
refid# 99QNKKaN6ab69kvB3qEwJvO631 page
946 , CHAPTER 38 1957 Guide changes in outdoor temperature is an example.
refid# 914GkyyJbjoDGX8VjjOEKKx4D1 page
1098 CHAPTER 45 1957 Guide openings are kept to a minimum size and are placed away from the natural path of the contaminant travel wherever possible.
refid# 06y8qdyYm643xZdoYYNDOdBdM1 page
1126 CHAPTER 46 1957 Guide Table 1.
refid# Ex8D4rx4gNENnvV9gEqL88M2g1 page
1160 CHAPTER 47 1957 Guide Step S: The pick-up of moisture per pound for the total air circulated is = 0.0051 lb. 0.0280 -- 0.0051 = 0.0229 lb moisture per lb of air for the supply air.
refid# 3ek3wB9q6naBMjoQjy0BjmDy31 page
388 CHAPTER 15 1958 Guide In the underfeed side-cleaning stokers the fuel is introduced at the front of the furnace to one or more retorts, and is advanced away from the retort as combustion progresses, while finally the ash is disposed of at the sides.
refid# km9G3BYpY7zYoeBYYenOoj7JD1 page
548 CHAPTER 20 : 1958 Guide being fastened to the bucket.
refid# ppnznbmQ7Q852Z7op2X3qK5Zk1 page
66 CHAPTER 6 1959 Guide promise.
refid# rBaY4gn8qxB9dok8nM6wE653v1 page
228 CHAPTER 16 1959 Guide Table 1 ....
refid# xdjn5bgGgpq0enyVra0XEVnrg1 page
398 CHAPTER 28 1959 Guide connections are rpftd> so that water travels from top to bottom in one coil and from'bottom to top in tlie other..
refid# MGMoyvXEKzjr9mqqrRBeO2KkM1 page
506 CHAPTER 35 1959 Guide A boiler that is just large enough to carry this system might be said to have a net load rating of 1000 sq ft, a design load rating of 1200 sq ft, or a gross load rating of 1440 sq ft, de pending on the basis on which the boiler is rated.
refid# ZBKpkMaEGkwMe1YLZE2MvKLN71 page