14 CHAPTER 2 1957 Guide Thermal conductance per unit area, Unit conductance: heat transferred per (unit time) (unit area) (degree).................................................................. ...
Document image
refid# 240MVYRVOB1dLvwmOMN6QrNb1 page
302 CHAPTER 13 1957 Guide Table 8.
Document image
refid# 93DOpp8r552rjDJ5b1DkmjK031 page
338 CHAPTER 13 1957 Guide Ventilation Air Taken through Cooling Unit Which Does Not Become a Part of the Space Load (see Equations 12 and 13): 5,, = 1275 X 1.08 (95-80) (1-0.15) = 17,600 Btuh, sensible. g,, - 1275 X 4840 (0.0169-0.0098) (1-0.15) = 37,230 Btuh, latent. at = 9.1 + s.x + g.i + 9.* = 3100 + 17600 + 6570 + 37230 = 64,500 Btuh total.
Document image
refid# YDm3KdEx4RLqJvE3re748jQd01 page
378 CHAPTER 14 1957 Guide " Condensation of Moisture in Flues, by William R.
Document image
refid# rpXv6ZBROXQzrO7zGezzxYgR01 page
460 CHAPTER 18 1957 Guide Substituting in Equation 1 p = i20,000 (Go.3 - 36.4) 5088 1.00[70 - (--10)]1000 243,000 lb.
Document image
refid# 4JxB52jjqarRdqNgz7aZ9y5Ma1 page
nearly horizontal.
Document image
refid# N2KeZeeEG10Ea7YjOprnYNkEy1 page
518 CHAPTER 20 1958 Guide vacuum.
Document image
refid# 93bRbxpn8kr9Ov6n8ve8rZ1931 page
524 CHAPTER 20 1958 Guide a similar basis for a given system and proportioned to the heating capacity of the radiators they serve, all radiators will heat proportionately to the steam pressure.
Document image
refid# DGBXekJOnb206wNONGxxgpyL41 page
584 CHAPTER 21 i-r1958 Guide' venting back-flow through the pump circuit is provided, r., Where .tempera-- tures higher than normal are maintained in the boiler, the connection of/the return 1ni!
Document image
refid# LoyKm7MNGaxMmpEykM77JVDBq1 page
610 CHAPTER 23 1958 Guide if The actual radiation transfer in a room may be somewhat different from that given by Equation 3 because of non-uniform..temperatures, irregular room surfaces, variations in erhissivity of materials, etc.
Document image
refid# YreGkOmr6aQbq2ewnKr5MGG2k1 page
.694 CHAPTER 26 1958 Guide used to produce acceptable welds.
Document image
refid# v14eR01y3bQMydO6z93G10rjZ1 page
720 CHAPTER 27 1958 Guide INSULATION OF PIPES TO PREVENT FREEZING If the surrounding air temperature remains sufficiently low for an ample period of time, insulation cannot prevent the freezing of still water, or of water flowing at such a velocity that the quantity of heat carried in the water is not sufficient to take care of the resulting heat losses that will cause the temperature of the water to be lowered to the freezing point.
Document image
refid# vVon1rwnMvjrVn79bvmd42Kq1 page
750 CHAPTER 29 1958 Guide / low for ordinary methods of distribution.
Document image
refid# 8VLjyVNvj59nZqD45pe05Ymxk1 page
1002 CHAPTER 39 1958 Guide : The report of a joint committee of AIEC-EEI-NEMA recommended three application rules taking into' account the greater annoyances re sulting from frequent motor starting during lighting hours against infre quent starting at any time.
Document image
refid# 8VvYMkXMaqYao3Xd3jvJ0vJjm1 page
Heating Ventilating Air Conditioning Guide 1959 Duet, ducts (continued) construction details, 239, 298, 708-711 design, 240. 292, 707 design methods, 292 equal friction, 293 static regain, 294 velocity reduction, 293 dual duct, 263 dynamic losses, 287 elbow friction losses, 289 exhaust design 707 friction losses, 285 heat loss coefficients, SIO, 301 lining, 345, 346 measurement of velocities, 632 perimeter, 240 pressure changes, 283 pressure loss, 283, 285 rectangular equivalents of round, 287289 resistance, 255 roughness correction, 286 sizing, 2S4, 285, 292 sound absorbers, 344-347 symbols for drawing, 10-12 system design, 237, 2S3, 295, 707 velocities, 293, 295 warm air perimeter, 240 weight, 299, 300 Duct sizing, 284, 285, 292-297, 707 equal friction method, 293 general rules, 707 static regain method, 294 velocity method, 293 Dost, 2, 62, 73 combustible, 80 concentrations, 79 control, 84 counter, 74 determination, 73 filters, 324, 329, 331 industrial, 76 particle size chart, 74 preripitatora, 325, 332 removal, 323 size, 74 Dost collectors, 323, 329 application, 323, 327, 329 centrifugal, 329, 330 cyclone, 330 cloth, 331 degree of dust removal, 329 electrostatic, 332 fabric, 331, 332 factors affecting selection, 329 inertial separators, 329, 330 settling chambers, 330 scrubbers, 330, 331 fewfing method^ 39ft types, 329 wet, 330 centrifugal, 331 packed tower, 331 spray towers, 331 washers, 331 wet filters, 331 Dynamic head, 3, 287 losses, 287 .E EDR (Equivalent Direct Radiation), 4 .356 defined, 4, 207 Effective temperature, 5, 66 chart, 67, 68-70 index, 66 Efficiency boiler, 504 conversion burner furnace, 511 utilization, 527 Ejector nozzles, 275 Elbow attenuation, 345 copper equivalents, 396 friction losses, 289, 290, 396 iron equivalents, 396, 416, 752 sheet metal, equivalent, 290 Electric, electrical baseboard, 232 convector, 232 demand control, 235 heat applications, 231 heating, 231 calculating capacities, 234 central, 234 control, 235 domestic water, 756 equipment, 232 heat pump, 234, 563 operating costs, 235 power considerations, 235 resistors, 5, 231 systems, 232 Units, 232-234 hot water heating, 756 installation methods, 232 motor design limits, 640 panel heating, 233, 234, 432 precipitators, 332, 335 radiant convector, 233 radiant beating, 233, 432 resistors, 231, 233 steam radiator, 233 systems, 232, 609, 639 voltage ratings, 640 Electricity, static, 87, 689 Emissivity, 52 Enclosed radiator, 271 Energy, Conservation Law, 13 Enthalpy, 2, 13, 16, 17.27 free, 2 specific, 2, 16 Entropy, 2, 16, 17 mixing, 17 specific, 2 Equivalent evaporation, 2 Estimating fuel consumption, 527 Eup&theoscope, 634 Evaporative apparatus for heat rejection, 579 condensers, 589 cooled, unit conditioners, 223 cooling, Ml, 597 Evaporators, 557 Excess air, 470, 477, 479, 490, 495 Exhaust opening, 279, 701 measurement of velocities, 632 Exhaust systems, 701 air flow equipment, 711 axial velocity formula, 702 capture velocities, 701 construction, 708,' 709, 711 conveying velocity, 704-706, 711 corrosion, 712, 713 duct construction, 708-711 duct design, 707-711 duct resistance, 708 duct system design, 707 duct velocity, 704-706 ducts for, 707 air velocities in, 704-706 construction, 708 xiv Exhaust systems (continued) design, 707 resistance, 708 dust filters, 711( elements, 701 equipment, 701, 711 exhaust requirements, 709, 710 general requirements, 701 hoods, 701 air flow, 702 air velocity, 702 axial velocity formula for, 702 canopy, 704-706 capture velocities, 701 chemical laboratories, 705 design principles, 701 hot processes, 703 induced air flow, 707 kitchen, 705 special exhaust requirements, 703 spray booths, 706 suction, 712 velocity contours, 702 .- ventilation rates, 704-710 make-up air, 711 maintenance, 712 materials, 709, 711-713 performance, 712 pressure loss, 708 specifications, 708 suction requirements, 712 types of fans, 711 velocity contours, 702 velocity requirements, 704-710 ventilation rates, 704-710 ' Expansion factor, gases, 42 of pipe, 380 tank installation, 403 tank piping, 403 tank site, 404 tanks, 403 valves, 557 Explosion hazard, 86 Extended plenum systems, 244-247, 250 F Fan, fans, 303 applications, 310 arrangement of drives, 308 attic, 311 location, 311 axial flow, 303 central system, 1, 310 centrifugal, 303, 305 characteristic curves, 305-307 control, 307 designations, 304 drive position, 309 efficiency, 305 exhaust, 310 furnace system, 2, 327 hot gas, 311 installation, 310 kitchen, 311 laws, 301 marine, 310 mine, 310 motive power, 308 noise generated, 339 oil burner, 488performance, 303, 305-307, 342 propeller, 303 radial flow, 303, 306 rotation, 308 selection of, 309 air-conditioning systems, 310 industrial exhaust systems, 711 special application, 311 Index to Technical Data Section Fan, fans (continued) speed, 309, 310 ____ system characteristics, 306 types, 303 unitary systems, 310 velocity, operating, 309 volume control, 307 Fanning formula, 36, 393 Fever therapy, 89 .
Document image
refid# QkVDpqZDrKz0pJOmZ9zXxX0V71 page