804 CHAPTER 36 1951 Guide With the pressure actuated device, the^control ia frequently located directly on the condensing unit, and the low pressure in the suction line or the crankcase of the compressor is used to control motor operation.
Document image
refid# JrEYVqvw7Ze5D2RmdjM1GD7nr1 page
826 CHAPTER 38 1951 Guide trolled device.from one controller to another, or to reverse the action of a controlled device in response to an impulse from a controller. 4.
Document image
refid# OxgL5BJ15Z4KmEpN5aLdpe4j1 page
944 CHAPTER 45 1951 Cuide Design Based on Total Air Flow Where the foregoing factors are not known, the usual method of de signing an exhaust system is to base the air flow through the system on rates of flow (through each hood) which have been found by experience to provide adequate control.
Document image
refid# wrqGpjGyQmVDmYe9xwz1zm4mE1 page
1018 CHAPTER 48 -1951 Guide requires no fuel.
Document image
refid# jgRw5Qg70a1Zw7o8jX3O2j5N1 page
Treating Ventilating Air Conditioning Guide 1952 Condensers, 816 air cooled, 816 design data, 758 evaporative, 816 water cooled, 816 Condition line, 59, 309, 633 Conductance, 3,167, 170,' 180 air space, 170,178 building materials, 171, 180 insulators, 174,180, 606 soil, 169 surface, 177, 684, 765 Conduction, 3, 89 drying methods, 989 electric heaters, 893 equation, 90 steady-state solutions, 101 Conductivity, 3, 89. 174, 180 bat type insulation, 174, 180 building boards, 174, 180 building materials, 174, 180 homogeneous materials, 169 insulating materials, 174, 175, 180, 181, 606 insulation blankets, 174, 180 insulators, 174, 180, 606 loose-fiU insulation, 175, 180, 187 masonry materials, 171, 180 plastering materials, 173, 180 reflective insulation, 170, 180 rigid insulation, 175, 180 roofing construction, 173, 181 soil, 176, 177 woods, 173, 181 Conductor, 3 Conduits for piping, 621 Control, controls actuated, 841 actuating, 840 airborne infection, 132 all-year conditioning, 630, 844, 848 application, 846 automatic, 458, 839 fuel appliances, 361, 843 temperature, 844 basic types, 839 central fan system, 629, 848 all-year system, 629, 848 heating cycle, 635 coal-fired plant, 842 compressor, 847 cooling units, 848 dehumidification, 848 . dehydrating equipment, 833 designation, 839 district heating, 851 draft, 326 electric heating, 843 electronic, 839, 853 equipment for motors, 866 fan, 716 gas burner, 843 gas-fired appliances, 843 heating unit, 842 hot water supply, 1031 humidity, railway care, 1000 ice bunker, 847 indicating, 854 individual rooms, 1010 limit, 843 modulating, 844 motor, 820 oil burners, 842 panel heating, 852 pneumatic systems, 839 rate of biochemical reactions, 947 rate of chemical reactions, 945 rate of crystallization, 947 recording, 854 i- Control, controls (continued) refrigeration equipment, 813, 847 compressor type, 847 ice cooling, 847.
Document image
refid# v12G3XBO7vvzpjxjxDoKRmqQb1 page
28 CHAPTER 3 1952 Guide gas is heated or cooled at constant pressure, the volume V varies as the absolute temperature T.
Document image
refid# 82b11OvM4ekXeobryNrxONwgB1 page
80 , , CHAPTER 4 1952 Guide 8, respectively.
Document image
refid# N2m67825qoZn8a2vNDzZqngoV1 page
222 CHAPTER 10 1952 Guide where Q = air flow, cubic feet per minute.
Document image
refid# EmmYJEdvav5Bjn66q3aMONqJn1 page
252: CHAPTER 11 1952 Guide Fig. 3.
Document image
refid# npaydOzjrMyEjovbrDdB5Mx8R1 page
350 CHAPTER 13 1952 Guide Table 10.
Document image
refid# ykpq1KrN028VbgD8JrRMQg9r21 page
584 CHAPTER 25 1952 Guide i- Many prime surface coils utilizes flooded expansion as obtained with a float valve to improve the heat transfer coefficient.
Document image
refid# ga30r7259qgwxxe1n6qp6abQL1 page
600 CHAPTER 26 1952 Guide sizes either cast-iron, cast-steel or some of the steel alloys are employed.
Document image
refid# X7Xo7npXary5gZXppwOwe5eRJ1 page
826 CHAPTER'36 1952 Guide I' that the powerirequired by :the reciprocating compressor increases rapidly with increase, in condenser -temperature^ while the power curve for the centrifugal compressor is relatively flat.
Document image
refid# EX2Y9Vy55Zjqd42MbkqO7qbL1 page
1052 CHAPTER 49 1952 Guide -but some walls are complicated by the inclusion of metal, for instance, and tests for conductance are required.
Document image
refid# vy1voG906OKQxB1O0kpo6p9aR1 page
234 CHAPTER 11 1953 Guide The following recommendations do not apply to so-called pen stables or loafing barns in which there is a thick manure and bedding pack , on the floor, and in which doors are normally kept open
Document image
refid# K6rdo6RLax9rR9jx3k88X2Djr1 page