HEATING VENTILATING AIR CONDITIONING GUIDE 1940 Pelham Manor-- White.
Document image
refid# 0go6dboZ9qZ3azqN8yZvByp6m1 page
"T HEATINC VENTILATING AIR CONDITIONING GUIDE 1941 MAXIMUM DEMANDS AND LOAD FACTORS In one form of district heating rates, a portion of the charge is based upon the maximum demand of the building.
Document image
refid# MGnN78GEomOr7pedzOmjdVZXj1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1941 3.
Document image
refid# qmyz8n012dKwQ0Vm5ye2d6MgG1 page
HEATING VENTILATINC AIR CONDITIONING CUIDE 1941 Rapid condensation of steam, especially during heating-up periods, is characteristic of this, type of equipment.
Document image
refid# vy9Qvd2DdKMV16jy1K3KGXwYR1 page
T a b l e 2.
Document image
refid# 9KDDwVbeDw5RNV9ZddwznG5p1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1942 factors in the increased susceptibility to gastro-intestinal disorders in hot summer weather.
Document image
refid# 0KVdNrZmdeO9Kr2LXRX9Na7b1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 Table 4.
Document image
refid# b5qggzZD1pm4ordLNvK0m6mp31 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 a second-stage reduction.
Document image
refid# YG123zDdMw7OOVkeMbgbR1BzV1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 Use of socket welding fittings generally is restricted to nominal pipe size 3 in. and smaller in which range commercial fittings are available.
Document image
refid# kDmBOYLQd3dbyobRmmM2E8d0V1 page
HEATINC VENTILATINC AIR CONDITIONING CUIDE 1942 3.
Document image
refid# GKmzO3M2dz6bOn1bNv21oqGmY1 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1942 Table 7 Pressure Losses in Dichlorodifluoromethane Discharge or Hot Gas Lines1 Pressure Drop in Pounds per Square Inch per 100 Ftb Capacity Btu pbb Hour Line Sizes, Inches K H K lM ik ik 2H 2K m m 10,000 15.000 20.000 25.000 30.000 40.000 50.000 60.000 70,000 80,000 90,000 100,000 125.000 150.000 175.000 200,000 250.000 300.000 400.000 500.000 600.000 800,000 1,000,000 1,250,000 1,500,000 2,000,000 2.3 4.9 8.5 1.0 2.0 3.4 5.3 7.5 0.6 1.0 1.7 0.6 2.6 3.6 6.4 9.8 0.9 1.2 2.1 0.5 0.7 3.1 4.4 6.0 1.0 1.3 1.9 8.0 10.2 2.5 3.1 3.8 6.0 8.5 11.6 -- 0.5 0.7 0.9 1.1 1.4 1.7 2.6 3.8 5.1 6.7 10.4 0.5 0.7 1.0 1.3 1.7 2.6 3.7 6.7 10.5 0.6 0.9 1.2 2.2 3.5 5.0 9.0 0.5 0.9 1.5 2.1 3.8 5.8 9.5 / 0.7 1-0 1-8 2.9 4.4 6.4 11.3 Soft annealed copper tubing up to and including % in. outside diameter, Hard copper pipe % in. outside diameter and larger. bLength of tubing includes the average number of fittings. control and regulating valves must be added to the other pipe losses to' determine the total drop.
Document image
refid# pBRjdgGM2m6mjG1epyXgGR6R71 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1942 offices, hospitals, and, most of all, radio broadcasting and movie sound studios, present a real problem which must be intelligently attacked if a satisfactory installation is to be made.
Document image
refid# om1da3jeXgwop3rQBV6Mp9M6X1 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1942 TYPES OF AUTOMATIC CONTROL Operating Medium or Source of Power Supply Automatic control systems may be classified in three broad groups based upon their primary operating media or sources of power, as follows: 1.
Document image
refid# 9Lom910XR447LKyqzDj6EN5JL1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 Example 8: An apartment building has a hot water requirement as follows: 60 lavatories............................ ..........:.....................................
Document image
refid# Z4VDVBgd9yv171DBE0mrX46Rp1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 HATCH, O.
Document image
refid# p2Mw7Z3Qzm4OQ0q6jRovgEMX61 page