Refine
Estimated Years 1940-1949Clear
11,527 results foundRefine Search
HEATING VENTILATINC AIR CONDITIONING GUIDE 1940 4.
Document image
refid# eLoENXXzYdGbRGYVxeO8jqzM1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1940 Anthracite Industries Laboratories Publications: Report 2015, Comparison of Sizes, Egg, Stove and Chestnut Anthracite.
Document image
refid# MGak1EB5aM6ZvxxRYypeedqnV1 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1940 PIPE SIZES The determination of pipe sizes for a given load in steam heating depends on the following principal factors: 1.
Document image
refid# gDpY6K0X8xmga9BDEy6nrBOn91 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1940 The size and location of the vent7 outlet is important.
Document image
refid# 6wpYD9meg4MO05OaaGGv1yzqR1 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1940 and 4 or 5 times practically, as the work put in.
Document image
refid# Qgo53kMQ128XB1R4BZJyZ2R241 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1940 brought up to 50 per cent humidity at 150 F.
Document image
refid# 6RMdBdppnn2GBKz3yNEMQjnBm1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1940 gravity action).
Document image
refid# 5b8qxzqxLdgXYBdMayGx72mYN1 page
HEATINC VENTILATING AIR CONDITIONING CUIDE 1940 Detailed Computation Method The area in square feet of each type or temperature of surface, hori zontal or vertical, is multiplied by the emission value corresponding to its actual surface temperature.
Document image
refid# RJ64za7NE78ryyRD8xZN7kv9E1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1940 President______ 1st Vice~Presidrnim End Vice-President-- Treasurer_________ Secretary 1912 ______John R.
Document image
refid# MM2VDLeJXKqYR1O5nD7Qy9BLx1 page
HEATING VENTILATINC AIR CONDITIONING GUIDE 1941 Fuel oil (continued) grade of, 160 heating value, 710 maximum carbon dioxide^values. 149 theoretical air requirements, 147 viscosity, 160 Fumes, 525, 794 Furnace, furnaces, 360, 794 - capacity, 351 casings, 360 design, 190, 224 fan, 794 gas-fired units, 199 gravity systems, 345mechanical systems, 359 oil-fired units, 195 stoker-fired units, 188 volume, 159, 794 G Gage, gages draft, 630 pressure, 630, 794 Garage ventilation, 725 Gas, gases burner controls, 623 chimneys for heating, 181 classification of. 161 cleaning of, 540 centrifugal separators, 540 cloth filters, 541 cyclones, 540 gravitational settling chambers, 540 combustion of, 162 estimating consumption, 215 fuel burning rate chart, 210 specific heat, 807 Gas-fired appliances, 199 boilers, 199, 223 combustion process, 202 controls, 203 conversion burners, 202 furnaces. 199 measurement of efficiency of combustion, 202 ratings for, 203 sizing heating plants, 203 space heaters, 201 - Gaseous fuels classification of, 161 combustion of, 162 flame temperature, 162 maximum carbon dioxide values, 149 products of combustion, 162 properties of, 162 specific gravity, 162 theoretical air requirements, 147 Glass solar heat transmitted, 132 Glass blocks coefficients of transmission, 97 beat gain through, 135 Globe thermometer, 68,637, 768 Graphical symbols for drawing, 803 duct* work, 804, 805 heating, 806 piping, 803 ventilating, 806 Grate area, 794 Gravity convectors, 239 codes, 247 concealed, 245 electric heaters, 751 heat emission of, 239 heating up, 243 selection, 246 Gravity furnace systems, 345, 794 capacity, 351 design procedure, 345 leader sizes, 346 proportioning wall stacks. 348 recirculating ducts, 349 recirculating grilles, 349 register selections, 349 return connection, 351 typical design, 355 warm air. 345 Grille, grilles. 557 {see Registers) locations. 558 for mechanical furnace systems, 363 noises, 564 railway car, 666 . recirculating, 349 types of, 569 Guarded hot plate, 637 Gun type oil burners, 193 Hay fever symptons, 661 Health. 528 Heat, 205, 794 auxiliary sources, 119 coefficients, 69 by convection, 727 by radiation, 727 of combustion, 145 emission of appliances, 136 emission of occupants, 135 flow through roofs, 131 flow through walls, 131 generated by motors, 137 humid, 794 infiltration equivalent, 109 introduced by outside air, 136 latent, loss. 109 of the liquid, 794 losses from bare pipes, 732 control of, 759 from ducts, 738 from insulated pipes, 736 mechanical equivalent of, 795 methods of, transfer, 69 production, rate of, 760 removal, natural ventilation, 722 residence; loss problems, 121 sensible, 796 sensible, loss, 109 total. 797 transfer. 473. 483, 492 boiler rates, 226 through building materials, 637 ' overall coefficient of, 484, 492 surface coils, 473 transmission, 727 Heat exchange measurement of,. 637 XVI f ALPHABETICAL INDEX TO TECHNICAL~DATA SECTION Heat gain, 125 appliances, 136 components of. 125 electrical heating equipment, 138 gas burning equipment; 138 glass, 132 through glass blocks, 135 ( insulated cold pipes, 742 for insulated ducts, 743 for insulated pipes, 743 latent, 127 light, 137 occupants, 135 outside air, 136 people, 135 . roof. 127 sensible, 127 steam heated equipment, 138 unit, 390 from various sources, 138 wall. 127 Heater, heaters, electric, 750 water, 785 Heating, for air conditioning units, 408 boilers, 221 surface, 791 boiler surface, 225 coil selection, 497 cycle control, 610 district. 307 domestic water by electricity, 755 electric, 749 hot water, 754 extended surface, 793 load.
Document image
refid# K6kYmJqbRy13d493zxKLook4K1 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1941 Little is known of the identity and physiological effects of the organic matter given off in the process of respiration.
Document image
refid# L0Gz57XrJJkw7Lzb7LM3YmQg1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1941 employed in the operation of large plants during the periods when the boilers are operated only up to their normal rating.
Document image
refid# e72eaKMLebrgB07x66kwwXVwG1 page
HEATINC VENTILATINO AIR CONDITIONING CUIDE 1941 MicronMiles per hour.__ Millimeter.............
Document image
refid# wyaXzjdgx2kmBDqeZEkw04e41 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1941 HALL.
Document image
refid# EvONqkMq22aDDZpYm8BezRwjn1 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1942 BOILER EFFICIENCY The term efficiency as used for guarantees of boiler performance is usually construed as follows: 1.
Document image
refid# JEp8wZwM2K3B93ngZXxZVGzO1 page