HEATINC VENTILATING AIR CONDITIONING GUIDE 1941 GAGES, Compound American Radiator & Standard Sanitary Corp., 992-993 Crane Company, 998-999 .
Document image
refid# 3JpynG3EkZBBwpZB02JLKpRoa1 page
Summer Air Conditioningfor Residences--M.
Document image
refid# reKa6KVV4bov1d0EQnjVqjyg01 page
Heating Ventilating Air Conditioning Guide 1942 ; o' i ;j
Document image
refid# xg8rKpB1kOVYE3ZQ6ygDLk061 page
T able 6.
Document image
refid# qN87GNrgjwJ6k2B9KbQQYrKq1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1942 CHAPTER 10.
Document image
refid# MG5mzmRbz12VORybYGKZJdXbV1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1942 a ][ Fig. 11.
Document image
refid# zdRrYoynE1QwXN0JOJExqpRqm1 page
HEAT1NC VENTILATINC AIR CONDITIONING CUIDE 1942 equations of heat transfer, mean temperature difference and coil efficiency: ft=/sXoX MTDa (7) MTVa = -------- k~k 2 3 'og.oQ _ 4) (8) E = th--"----h7 (by definition) Qa = 0.245 X w X (fi - t,) (9) (10) Qa = sensible heat transferred, Btu per hour per square foot of coil face.area. h = temperature of air entering coil, degrees Fahrenheit.
Document image
refid# OLXgredXvvMqwvgrq9y5J6Vw1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1942 equipment and ventilating means available for control.
Document image
refid# mb5EZJmxRmNBm0z7BdeRMjN01 page
HEATING VENTILATING AIR CONDITIONING CUIDE 1942 Graphical Symbols for Drawings 45.
Document image
refid# Z2eoNayLZo5bQ9Ld6qEbDJQL1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 Flow meters, 339 Fluid meters, 338 Force, 846 Forced air heating system, 388 circulation pipe sizes, 313 convection, 72 Free convection, 72 enthalpy. 846 Fuel, fuels. 165 burning equipment, 205 consumption, 227 load factors, 239 maximum demands. 239 seasonal efficiency, 240 unit consumptions, 234, Fuel oil . carbon residue. 182 classification of, 181 combustion of, 181 grade of, 182 ' maximum carbon dioxide values. 171 theoretical air requirements, 169 viscosity, 182 Fumes, 555. 846 Fundamentals heat transfer, 71 Furnace, furnaces, 383, 846 capacity, 376 casings, 384 design. 214 fan, 846 , gas-fired units, 221 ' gravity systems. 369 mechanical warm air systems, 383 cooling methods. 393 cooling system. 394 dampers, 386 ducts. 387 fans. 385. 391 filters. 385 method of designing, 388 .
Document image
refid# VG83Dp6v2BZKBYJkZmk200Xp41 page
HEAT1NC VENTILATING AIR CONDITIONING GUIDE 1943 liminary calculation shows that the final mixture contains liquid, The final weight, of water per pound of dry air is determined from 33.96 + (W -- 0.01574) X 38.0 - 17.98 W - 0.00331 1156.3 where the specific enthalpy of the injected water is 1156.3 Btu per pound.
Document image
refid# zokBpeYkzNdpjKbJO9x7ROaX01 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1943 through cracks or porous construction, and a similar quantity of air leaves on the leeward side through like openings.
Document image
refid# DM1VbEaZdvEZ4OQ2XwGN6rgqd1 page
HEATINC VENTILATING AIR CONDITIONING GUIDE 1943 Summary: Component of Load Normal ^Transmission" ^ Radia"0n Transmission........... ,,.... .........
Document image
refid# zQqGZb4VgVJXJ9qd86rkV3y6z1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 The entering air temperature for standard test conditions is 65 F.
Document image
refid# 06dn0YX5G5nOnbj5EXGgEzJjb1 page
HEATING VENTILATING AIR CONDITIONING GUIDE 1943 maximum hourly load.