616 CHAPTER 35 , 1946 Guide Typical Specifications for Wound Rotor Motors f208] ________ ....................................RPM, {gjjj Cycles, Volts, ||| Phase, Wound Rotor l55oJ Induction Motors For Driving................................................
refid# oDQ24ZkjYNxG89VEgjorx2BgR1 page
miff, 676_________________ CHAPTER 38 1946 Guide Fig. 9 are based upon 75 F cooling water.
refid# 4kjp8718YeNJjB5Qx80ELnRx1 page
694 CHAPTER 39 1946 Guide In exactly the same way representation on the ideal cycle can be given to the pressure losses that occur in the connecting piping.
refid# X7Znp0NNV6rvaRxQO2xDO4LMG1 page
752 CHAPTER 41 1946 Guide Table 4.
refid# em9yLeQ0QRrYeagqOpdwbza0E1 page
Insulation United States Gypsum Company General Offices: 300 W.
refid# MJD8Y6MVVxLdJvR7303jObmr91 page
340 CHAPTER 17 1948 Guide i" _ In those installations,, in mild climates where 100 per cent outside air is used, furnaces should be of larger size in order to provide adequate capacity and quick pick-up under intermittent heating conditions. .
refid# NGOXORd77dzMn47v8y2dxY3Bp1 page
394 CHAPTER 20 1948 Guide -plant.
refid# Dvn1kJXZ36BbpQkNmkwOQN4La1 page
616 - CHAPTER 38 1948 Guide may'Jje obseryed,by'refemng. tp Fig: 1- When the given, type of solid adsorbent' is. in equilibrium with. air'having a dry-bulb' ^temperature 'of 70 F and;.7P per cent relative humidity, that is, having`a.dew-point of 60 F or d'water'vapor pressure,of 13.2 mm Hg, the 'water,content'of the' ' adsorbent is 33 per cent,- 'With air having'the same dry-bulb temperature' and a dew-point of 37 F,or a vapor pressure of. 5.6 mm Hg, the water content is 20 per cent.
refid# jgmpEg8dErvg5ovwE2dxm9Rmy1 page
Copyright 1949 '' BY THE American Society of Heating and.
refid# eyxDe3wb36zZjXbaprv762O91 page
274 CHAPTER 15 1949 Guide States.
refid# YGOgVDjvMODRg1Md20EBjjaVN1 page
580 CHAPTER 28 , 1949 Guide PIPE INSULATIONS Pipe insulations are of several general forms and are made of various types of material.
refid# B47J0YYavjqObvO8byXoxg4o1 page
776 CHAPTER 39 1949 Guide pressure be maintained inside the compressor during discharge than in the condenser.
refid# vj9m1KnGzQ46Nm6LMXv6JkJb1 page
798 CHAPTER 40 1949 Guide to neutralize any undesirable cold drafts or radiation, effects set up by a concentration of the heating or cooling load.
refid# e5GnxjYpMvxRMdLLgN7DxyEJe1 page
498 1 i CHAPTER 21 19S0 Guide EXPANSION TANKS Water heated from 40 F to 200 F expands about 0.04 of the original volume.
refid# 7O5522N8mryB7NyGq03bXL1wR1 page
I9 .t Vol. 3 August, 1941 Staff Hygienist Covers 2700 Miles in 3 Days Three Field Ken Now Busy with Plant Surveys In helping member companies "keep precautions apace v.lth production," one of the Foundation'3 industrial hygienists has averaged 2,000 milos a month for the past year.