American Society of Heating and Ventilating Engineers Guide, 1936 6 Use the degree-day method of computing the amount of coal required to ' heat an office building located in Cleveland, Ohio, assuming that the net, heated space is 30,000 cu ft.
refid# ZnEqQjVJynZy2Rxwy2j31rzQJ1 page
American Society of Heating and Ventilating Engineers Guide, 1936 SWANSON, Rolf G. (5 1935), 324 Walnut St.
refid# OJ47xe3qD0gpR9mYz72zqVBye1 page
American Society of Heating and Ventilating Engineers Guide, 1937 ht -- hi = the increase in the heat content of the air-water vapor mixture in passing through the apparatus, Btu per pound of dry air = 0.24 (<, - ti) + W, (1059.2 + 0.45 /,) - Wi (1059.2 + 0.45/,) The net quantity of heat added to or removed from air-water vapor mixtures in air conditioning work is frequently approximated by taking the differences in total heat at exit and entrance.
refid# GKLbee41V8ymbnpqLVyZBXL9v1 page
American Society of Heating and Ventilating- Engineers Guide, 1937 cfm 200 X 13.5 (30.85 - 20.35) 257 cfm per ton. 257 X (76.0 - 14.4) X 1044 175.2 Btu. 13.5 X 7000 )Check: L = 200 - / 257 \ X 0.2415 13.5 X 5 177.0 Btu. 9 Why is it possible for a reversed cycle refrigeration unit to show a better . performance in heating operation than when operating during the cooling season?
refid# OJ1eOnEM85Yj706L7OyxbebNK1 page
D iam eter ,s>f ' Branch Pipe M a in a n d B ranch Pipes for E q u a l F r ic tio n per F oot of L en g th (20 to 100 Per Ce n t Ca p a c ity ) American Society of Heating and Ventilating Engineers Guide, 1937 8S $ 370 ,id d Chapter 20-^Air Duct Design maximum velocities with good construction and design may be as high as 2000 or 2200 fpm in main ducts, with suitable reduction in branches and outlets.
refid# 50bLGpk54o4vMpN6bdqqOwg41 page
American Society of Heating and Ventilating Engineers Guide, 1937 FURNACES Furnaces for mechanical warm air systems may be made of cast-iron steel, or alloy.
refid# 5Q5zVQRbRz5b6bvx5pMbemx51 page
American Society of Heating and Ventilating Engineers Guide, 1937 tensity and is analogous to the total dynamic head in a water works system.
refid# 9YLaN3wEeJZejo5KZmmGdRr51 page
American Society of Heating and Ventilating Engineers Guide, 1937 Fig. 1.
refid# 82kr1eBXdxX64BrmXeyzwrn3e1 page
American Society of Heating and Ventilating Engineers Guide, 1937 Referring to the column for an equivalent total length of 300 ft for Sections AB and KA, each supplying 117.6 Mbh, it will be found that a lj^-in. pipe is too small and a2-in pipe is too large.
refid# vVN2p8gXGZMwLgMvb6Kodyy3R1 page
Publications Heating Journals, Inc. 232 Madison Ave.
refid# 8VYxk24VkmLymmj1pqzn1gYy1 page
American.
refid# 9300R7kK39LjGm21JG2ygG8bD1 page
t American Society o/ Heating and Ventilating Engineers Guide, 1937 OSTRIN, Albert (J 1936; S 1935). 1216 James N..
refid# zzXJOxrv1N6BNLvo20daYvL0R1 page
Heating Ventilating Air Conditioning Guide 1938 3 If 20 tons of coal having a calorific value of 13,000 Btu per pound are burned In a warm air furnace and produce 286,000,000 Btu at the bonnet, what is the efficiency of the furnace?
refid# XR6dazMYxp0m80Qw7gB76ZX0w1 page
F riction H ead in M ilinches per Root op' Pipe toooq Heating Ventilating Air Conditioning Guide 1938 loo 300 1000 Meat conveyed per Hour in iooo B.T.
refid# JNkrrVQNBmRovZyJVzj24Y2Ye1 page
Heating Ventilating Air Conditioning Guide 1938 8 t Do all unit ventilators introduce a constant amount of outdoor air?
refid# 2jgXBgw1rgRqq50jq2n85V6661 page