Refine
Estimated Years 1930-1939Clear
14,210 results foundRefine Search
American Society of Heating and Ventilating Engineers Guide, 1934 rod, by the welding flame.
Document image
refid# 919ejymKJm1YoGBXz6bnZ9QK61 page
American Society of Heating and Ventilating Engineers Guide, 1935 Air Quantity The quantity of air to be circulated through an occupied space, whether 4| by natural or mechanical means, or whether the air is conditioned or not, 3 must in all cases be sufficient to maintain the required standards of air j temperature, quality, motion and distribution.
Document image
refid# YGR2o9mnYp51z1dXkMg0Lp0mN1 page
American Society of Heating and Ventilating Engineers Guide, 1935 Heat is lost from a building by transmission through all of those sur. faces which separate heated spaces from the outside air or from unheated colder spaces within the building.
Document image
refid# a1ZOzmeObBNEz51E8kjpex9vN1 page
American Society of Heating and Ventilating Engineers Guide, 1935 sufficiently before it reaches the trap so the trap will not be held shut bv too high a temperature.
Document image
refid# dkJQ0wQO3rKv5zdO3qyRngQq1 page
American Society of Heating and Ventilating Engineers Guide, 1936 Ventilation (continued), openings skylights, 91 types of, 90 windows, 91 for public buildings, 359 purpose of, 95 quantity of air necessary for, 77, 531 . railway air conditioning, 257 by registers, 93 for schools, 72, 348 by stacks, 93 standards, 74, 790 for theaters, 348 Ventilator, ventilators, resistance of, 92 roof, 92, 779 ' unit, 218 (see also Unit Ventilators) Venturi chimney, 452 Vibration, insulation of, 333 Vitiation of air, 57 Volume, of air and saturated vapor, 10 conversion equations, 785 furnace, 779 specific. 3 of saturated steam, 27 of water, 30 W Wall, walls. air leakage through, 132 of chimneys. 465 fire. 379 heat transmission coefficients for, 105, 112, 114, 116, 118 radiators, output, 522 solar radiation on, 160, 161 sound transmission coefficients for, 331 surfaces, areas of, 104 time lag through, 162 Warm air heating systems, 782 gas-fired furnaces for, 502 gravity, 417 mechanical, 403 Washers, air, 201, 406, 772 capacity of, 203 specifications for, 204 types of, 201 Water, 41 boiling point of, 26 circulating, temperature of, 206, 663 from city mains, 180, 194 cooling, equipment, 204 efficiency of, 208 Quantity, 176, 206 temperature, 206 composition of, 26 density of, 26 domestic supply, 629 evaporation of, 211 factor of usage, 631 flow from fixtures, 630 freezing, 663 friction losses through pipes, 637 hammer, 560 heaters,.389, 645 heating, 629 hot, domestic supply, 643, 045 boilers, 279, 435 demand for, 649 electric heating of, 705 " pipe sizes for, 640 storage of, 648 heating systems, 587 (see also Bot Water Heat ing Systems) inches of water, 777 .
Document image
refid# 0n0N7m1MdvZQ8Qoab3z5gxvb1 page
American Society of Heating and Ventilating Engineers Guide, 1936 flows to the evaporator through an expansion valve which reduces its pressure arid regulates its flow.
Document image
refid# 7OLbRgZ29m9R8wRLkNw3RGaGa1 page
American Society of Heating and Ventilating Engineers Guide, 1935 PROBLEMS IN PRACTICE 1 9 What is the relation between the sensible heat loss from a building and the heat required for humidification?
Document image
refid# QXJBzRnKweoRVNQN9mg6R2wx81 page
American Society of Heating and Ventilating Engineers Guide, 1936 the casing above the level of the grate, in the furnace.
Document image
refid# NNErYjMGmq7ER8nby0rnnEp0w1 page
.^ American Society of Heating end .Ventilating Engineers Guide, 1936 Table 1.
Document image
refid# a4qzY71G33bZkxe8ZyxKkpp0R1 page
American Society of Heating and Ventilating Engineers Guide, 1936 Air Washer: An enclosure in which air is forced through a spray of water in order to cleanse, humidify, or dehiumidify the air.
Document image
refid# yr8pZG9k5NND4G7evjK94oyKd1 page
American Society of Heating and Ventilating Engineers Guide, 1937 Table 8.
Document image
refid# qRj43380VbL14mVKXzrEvQ0M1 page
American Society of Heating and Ventilating Engineers Guide, 1937 PROBLEMS IN PRACTICE X Dichlorodifluoromethane (Fn) at a saturated temperature of 30 F but superheated 25 F to 55 F is compressed to a saturation temperature of 90 F with a compressor having an overall efficiency of 70 per cent.
Document image
refid# vVy14LM1mMpJdEpEnEe3ErL1w1 page
of and 1937American Society Heating Ventilating Engineers Guide, Cannon showed that excessive loss of heat is associated with increased activity of the adrenal medulla12.
Document image
refid# dYDZjYpzQX9BLXL2rnjvbD3m91 page
Plaster (} / i in.) on metal lath--furred Plaster (H in.) on rigid insulation in .)-- furred Plaster (H in.) on rigid insulation (1 in.)
Document image
refid# wgVY97xOpY9YdxaBXLjyYzkDd1 page
American Society of Heating and Ventilating Engineers Guide, 1937 Substitute in Equation 15.
Document image
refid# pBj8G0jvjKya3rJzk3vQJn3ew1 page