Refine
Estimated Years 1930-1939Clear
8,921 results foundRefine Search
American Society of Heating and Ventilating Engineers Guide, 1932 Table 10.
Document image
refid# 0JZmNjdxQVwgQgOaOVNqkegjJ1 page
American Society of Heating and Ventilating Engineers Guide, 1932 Johns-Manville 733 Mundet Cork Corp. 629 Stewart Inso Board Corp. 727 Upson Co..
Document image
refid# 5DnRoGRRKRNJVKY5yg0pBRE4z1 page
iff?
Document image
refid# gbObNXrD3dY8oVyDmMQY54XaN1 page
American Society of Heating and Ventilating Engineers Guide, 1934 Table 1.
Document image
refid# zo3Xvp1qnVmxQYVZvV0wyg5mn1 page
American Society of Heating and Ventilating Engineers Guide, 1934 AREAS WHERE TRANSMISSION LOSSES OCCUR Heat is lost from a building by transmission through all of those sur faces which separate heated spaces from the outside air or from unheated colder spaces within the building.
Document image
refid# 7OaenEapgJxBbMyqv4OEQB83E1 page
T a b le 14.
Document image
refid# 99ZQ9nJBKOOy46zwgGYvp16xq1 page
American Society of Heating and Ventilating Engineers Guide, 1934 Carbon Monoxide Poisoning Carbon monoxide is a common form of poisonous industrial gas, met with in mines, foundries, coke-oven sheds, garages, and houses.
Document image
refid# em4ykJ3wO3aLw8qBz9Kd2vwKp1 page
<S3pfpKT - , American Society of Heating and Ventilating Engineers Guide, 1934 The sum of these values equals 0.2 4- 0.25 + 0.09 4- 0.10 4- 0.35 4- 0.12 4- 0.25 4- 0.1 = 1.46 in. which is the static pressure against which the system must operate.
Document image
refid# 2jKan4wGXV7YR0RD7eJJnazE71 page
Registers and Grilles Tuttle & Bailey, Inc.
Document image
refid# VG8m820GBOjd2anjJyXzn8MYK1 page
T able 3.
Document image
refid# OEbE6p1ry4EXK1w5pON0Y5Dje1 page
American Society 0/Heating and Ventilating Engineers Guide, 1935 SHEETS, Copper Bearing Steel Republic Steel Corp., 869 SHEETS, Copper Molybdenum Iron Republic Steel Corp., 869 SHEETS, Lead Coated Copper Revere Copper and Brass, Inc., 874 SHEETS.
Document image
refid# dQKMRX1aZMaDZey98kOy6JjEq1 page
American Society of Heating and Ventilating Engineers Guide, 1936 Based on an average cost of coal, water and locomotive lubrication of $0.001133 per pound of fuel burned and the following assumptions: generator and drive efficiency 80 per cent, locomotive mechanical ef ficiency (cylinders to tender drawbar) 90 per cent, 3.5 lb coal per cylinder horsepower and 6 lb of water per pound of coal, the cost of generating 1 kw of electrical energy would be $0.00738, and 100 lb of steam $0.01888.
Document image
refid# XzNxvVGep10YyO7Rb845qaowR1 page
of and 1936American Society Heating Ventilating Engineers Guide, 31--Chapter Steam Heating Systems risers to the dry return main through-water seals about :36 in. deep, as shown in Fig. 9, to prevent steam from one riser entering another and closing the air valves on the nearest radiators.
Document image
refid# 44bB3Gq8vGpvQq9xzJGy064Oa1 page
American Society of Heating and Ventilating Engineers Guide, 1936 .
Document image
refid# 91QgLKx9gRdn9E7qJgEr4Kzy31 page
American Society of Heating and Ventilating Engineers Guide, 1937"" W ~ weight of air circulated, pounds per hour. 0.24 = specific heat of air at constant pressure.
Document image
refid# 0gVE2BMOv2M59bp70QndvqoJO1 page