American Society of Heating and Ventilating Engineers Guide, 1937 mounted together in a single unit and supported on a track on the car under-frame on pneumatic supports.
Document image
refid# zdpyjDQNXq4eqLJrnx9pqV0n61 page
American Society of Heating and Ventilating Engineers Guide, 1937 Chapter 40--Air Conditioning for Industrial Processes permissible temperature.
Document image
refid# g86LYZVYy0BRoQw6dB3amxXe1 page
.
Document image
refid# x8kEKomeoQgxErrjpBnVN5Dy1 page
Heating Ventilating Air Conditioning Guide 1938 centage of outside air should be kept as low as possible to maintain the air in the proper condition in order to minimize the heat or cooling load.
Document image
refid# De5kmN3yNevG5n86jNMq54GO1 page
Heating Ventilating Air Conditioning Guide 1938 Further, the velocity contours are identical for similar hood shapes when the hoods are reduced to the same basis of comparison.
Document image
refid# 0ggaaegx1RMX50G5kzjqqeJYm1 page
1938Heating Ventilating Air Conditioning Guide LAUTERBACH, Henry, Jr.
Document image
refid# zo1d8NJBMjqMm1qnVrrZdJQVz1 page
Heating Ventilating Air Conditioning Guide 1938 New Castle-- Andrews.
Document image
refid# 3Q1xqrro1qZg9oDMEO24XVe701 page
Heating Ventilating Air Conditioning Guide 1939 In considering both the transmission and infiltration losses, the more ^ exact procedure would be to select the outside temperature and the wind ' velocity corresponding thereto, based on Weather Bureau records, which would result in the maximum heat demand.
Document image
refid# KGqvg9JeO1xqn1Dd9nRzOO11x1 page
Heating Ventilating Air Conditioning Guide 1939 As is the case with the complete combustion of almost all fuels, the products of combustion for gas are carbon dioxide (CO.) and water vapor with just a trace of sulphur trioxide (S03).
Document image
refid# GKqJ0YYMwkzVbQZkD6j983Xmv1 page
Heating Ventilating Air Conditioning Guide 1939 freezing temperature, throttling the steam supply may result in freezing the condensate in the bottom of the coil if the tubes are of the variety nof provided with internal distributing pipes, or an equivalent arrangement If these are used, there is little danger of freezing the condensate as lon as the leaving air temperature is not allowed to fall below about 40 pS As an added precaution with both steam and water coils the outside air inlet dampers are often closed automatically when the fan is stopped to avoid trouble caused by very cold outside air drifting in during off periods A typical arrangement of water cooling coils is shown in Fig. 11.
Document image
refid# X4Yw25Kerz97qxgO2w6BB94J1 page
Heating Ventilating Air Conditioning Guide 1939 brought up to 50 per cent humidity at 150 F.
Document image
refid# 2qGDVz6bn9Ln7yMVBwd67a39r1 page
1939Heating Ventilating Air Conditioning Guide Fulton Sylphon Co., 1116-1117 Johiuwn Service Co., 1120-1121 Kieley & Mueller, Inc., 1093 Manning, Maxwell & Moore, Inc., 1006 Mueller Steam Specialty Co., 1095 -Penn Electric Switch Co.. 1126 Powers Regulator Co.. 1124-1125 Spence Engineering Co., 1127 VENTILATORS, Roof Air Controls, Inc., 892 Airtherm Mfg.
Document image
refid# baJ5nMRmk8m0d6VJJXB4vMqbD1 page
Testing Laboratory United States Testing Company, Inc.
Document image
refid# JN3e40gBZ27eKDoBQgyae79Ge1 page
Chicago, votobsr 18th, 1937 Ur.
Document image
refid# M4am4wqXb8Z8Ep9MpnODKgyj1 page
P_n 3 <=>. 0; @ 0} r 'ZS' T.S'j References to Recent Liter:*.ture - 9 38 CAISSON DISL-.SE -- CLINICAL ND STATISTICAL STUDY.