Refine
Estimated Years 1920-1929Clear
5,061 results foundRefine Search
90 Am.
Document image
refid# 9JZZx7RZ8Zv82NgqjY0L2nV7V1 page
D ry-BBulb Temp. % Rel.
Document image
refid# 5kjL4G04OwzG1OJe9LzMOEQNz1 page
AMERICAN SOCIETYOF HEATING & VENTILATING ENGINEERS GDHTO the angle between dry and wet bulb lines.
Document image
refid# LJer9y1gOD7xxBRZzn0nkqv1b1 page
American Society of Heating and Ventilating Engineers Guide, 1924-25 25.
Document image
refid# wKQnMoZ339GxZZy4ywQ8jMzoB1 page
American Society of Heating and Ventilating Engineers Guide,'1.925-26 ',rCoN r-o< -h O Ooo' OO--cloMo-HOCcNoCt-N.
Document image
refid# nkppZwGVaxeONVrJmKXK831XG1 page
American Society of Heating and Ventilating Engineers Guide, 1925-26 TEMPERATURE AND HUMIDITY CONTROL Air washers require method of control of temperature to prevent freez ing by too low temperature and of overhumidification by too high temperatures of the air entering and leaving the washer.
Document image
refid# DGRrgvo263odYLVm9oeOamM0o1 page
American Society of Heating and Ventilating Engineers Guide, 1928 Since actual temperature differences vary widely in different parts of the country, it is desirable to adopt some standard basis for testing, such as 70 deg. inside and 0 deg. outside, and in very precise work make a correction for other temperatures.
Document image
refid# 2qVYybg9BEMXxbKd1ndZJVLMa1 page
American Society of Heating and Ventilating Engineers Guide, 1928 Table 1: Flow of Steam in Pipes f/oiv of Sfetrm //> f'z/oes oss xv fSessse/Br //v os. tos/ae D/am/ts* orP/rr /-v Ab/cmss --Le/vcm or P/bjt //v Prrr Wc/cstr or / Cufr orS/sam SV"Lbs o/r SrorA* /*& M/w P-O.OOO/52 f/ 4 ^LS. ) ( a/ oct^.
Document image
refid# oMaYwpYq2yqoJvXp3pVQk1vo81 page
American Society o/ Heating and Ventilating Engineers Guide, 1928 be found from Table 2 by multiplying the capacities found therein by constants given in Table 7.
Document image
refid# pBBJkd71Zjz90DYX8jpzmbBJw1 page
American Society of Heating and Ventilating Engineers Guide, 1928 Chapter XII--Industrial and Domestic Oil Heating The majority of the burners operate on the intermittent system but there are several that operate on a system known as the high-low where the burner is always burning but the flame intensity is varied to meet the temperature variation as indicated by the thermostat.
Document image
refid# x5kXRLKNVoE4G4zXEKQQ1D4gy1 page
American Society of Heating and Ventilating Engineers Guide, 1929 Unit heaters should be carefully air vented and usually a blast type trap of at least 50 per cent excess capacity should be used to take care of the load during the heating-up period.
Document image
refid# VJEXZgZKoqMdJLd96gjqnZVd41 page
American Society of Heating and Ventilating Engineers Guide, 1929 One heat equipment in this way takes the place of two.
Document image
refid# xz5Z84yg0E3kpO6LY6kZMnK211 page
American Society of Heating and Ventilating Engineers Guide, 1929 value found at the center.
Document image
refid# v180eNkmOnoJmMwZkj4E880Lq1 page
American Society of Heating and Ventilating Engineers Guide, 1929 can be covered, the closer the design can be fitted to the requirements.
Document image
refid# zZEpa7eokvow3eLxwdJzrVw71 page
I '9w"f h' *L -.fbii3dHealth Practices Pa.mphlet No. 9 1 1Ub .
Document imageDocument imageDocument imageDocument image
refid# ebDLv0YkMGM7M7gX1JmZmZ1412 pages