Refine
Estimated Years 1920-1929Clear
2,678 results foundRefine Search
A23 UNITED STATES GYPSUM COMPANY Sabinite Acoustical Plaster 300 West Adams Street CHICAGO, ILL.
Document image
refid# LKJDzv8k8wQp3GKv8QYJkekbz1 page
ARCHITECTS' SPECIFICATIONS FOR United States Gypsum Company's No Lime Trowel Sand and Float Prepared Finishes Specifications for Prepared Trowel Finishes 1-- Trowel Finish to be United States Gypsum Com pany's (Brand.)
Document image
refid# aJVM905j410mkEkaKn8J35yZY1 page
- u.
Document imageDocument imageDocument imageDocument image
refid# gaY47dao9eGonZnGKkRz8D00L7 pages
A \' MET-239 BEPOHT OF THE PHYSICAL EXAMIMTIOHS AHD X-EAY EXAlfflHATIOHS OP ASBESTOS WOEKEBS IB ASBESTOS AHD THETPOHD HIHES.
Document imageDocument imageDocument imageDocument image
refid# RjK3RK2B344918xQ178y1GYwE15 pages
TRCMt DiTEi MKkORXKDDH* Campbell, Third Tioe Prasld Or.
Document imageDocument image
refid# QBp4Rb6MKeYk75xExY2mqXb82 pages
1/V -V"*- : rr\*'.a-flC1*' K . / $Mti r *jMI * S"1. : Annals New York Academy of Sciences in this study 383 of 611 employees have worked for less than five years!
Document image
refid# jB82ZND0rkZRxxeKmKmr3n6821 page
CANCERS OF THE RESPIRATORY SYSTEM 435 i< of chemical agents are capable, in the experimental animal at least, of in fluencing the occurrence, incidence, or biological character, of pulmonary neoplasia.
Document image
refid# 3e04EYOpkZ3zrDB9450Qzz5x1 page
19 2 7 TRANSACTIONS OF THE National Safety Council SIXTEENTH ANNUAL SAFETY CONGRESS VOLUME I X September 26 to 30, 1927 The Hotel Stevens CHICAGO Copyright, 1928, National Safety Council CONTENTS Council Officers and Directors--.............--..................-..........................
Document imageDocument imageDocument imageDocument image
refid# 7MB7ZBv2bOwgN6Q4Z3QL4JjMj1,989 pages
AMERICAN BUREAU OF SHIPPING APPOINTED BY THE COMMANDANT.
Document imageDocument imageDocument imageDocument image
refid# JNyR2x7mL7B11rLbR8wpLqKqB7 pages
AMERICAN SOCIETY OF HEATING & YENTILATIN6 ENGINEERS 6UIDE.1923J DETERMINING BOILER CAPACITY REQUIRED FOR A PARTICULAR INSTALLATION First determine from the boiler manufacturer whether his complete line of boilers has been tested and rated according to the A.
Document image
refid# QX7exYLoZR4V9bXa2agBzoEp81 page
F ig . 17.
Document image
refid# N2j7JkNYOepVYbMZgdNaEEm481 page
American Society of Heating and Ventilating Engineers Guide, 1925-26 American Society of Heating and Ventilating Engineers Guide, 1925-26 HEAT LOSSES FROM INSULATED SURFACES Fig. 68 shows the losses from appropriately insulated surfaces compared with losses from bare surfaces.
Document image
refid# MZ4YYeZJM3aoXyY7QGpzrL2k1 page
American Society of Heating and Ventilating Engineers Guide, 1925-26 irig the free.area of discharge, even when open wide.
Document image
refid# b5mqzovjBn131eB1aOny781Qk1 page
American Society of Heating and Ventilating Engineers Guide 1926-27 Containing Design and Specification Data Useful in . the Planning and Construction of Modern Heating and Ventilating Installations--Prepared from the Society's Transactions--Investigations of Its Research Laboratory -- and the Practice of Its Members together with a Manufacturers' Catalog Data Section Containing Essen tial and Reliable Facts Concerning Modern Equipment AND A Consulting Service Section for Engineers also The Roll of Membership of the Society with Complete Index of Technical and Catalog Data Vol. 5 $3.00 Per Volume 972466 Published Annually by American Society of Heating and Ventilating Engineers 29 West 39TH Street New York /
Document image
refid# yk9a4Y6novN30eJrKJ40LaNx21 page
American Society of Heating and Ventilating Engineers Guide, 1926-27' American Society of Heating and Ventilating Engineers Guide, 1926-27 per degree temperature difference per hour (Curve 1, Trans.
Document image
refid# Yr6wjEJGQZD17Rx3pEB6ZeonE1 page