Refine
Estimated Years 1920-1929Clear
2,678 results foundRefine Search
American Society of Heating and Ventilating Engineers Guide, 1928 separating tank is generally used.
Document image
refid# dad6jkr55bdQmjzmLJryqZ2z51 page
American Society of Heating and Ventilating Engineers Guide, 1928 Schools: Classrooms..... .................................. 2.0 cu. ft. per minute per square foot of floor area Assembly rooms............................. 1.5 cu. ft. per minute per square foot of floor area Gymnasia.... ....... 1.5 cu. ft. per minute per square foot of floor area Picture Machine Booth--...... ..... 1.5 cu. ft. per minute per square foot of floor area Dining-rooms--.......................... 1.5 cu. ft. per minute per square foot of floor area Kitchens.... ................... 2.0 cu. ft. per minute per square foot of floor area Corridors.......................................... 0.5 cu. ft. per minute per square foot of floor area Wardrobes and lockers................ 2.0 cu. ft. per minute per square foot of floor area Toilet, Bath, Etc.....'...................... 2.0 cu. ft. per minute per square foot of floor area Theatres: Seating spaces--.............. -............. 2.0 cu. ft. per minute per square foot of floor area Toilets, etc....................... 2.0 cu. ft. per minute per square foot of floor area Hotels: Assembly rooms....... ............ 2.0 cu. ft. per minute per square foot of floor area Dining-rooms.................................. 1.5 cu. ft. per minute per square foot of floor area Kitchens................................ :......... 4.0 cu. ft. per minute per square foot of floor area Hospitals: Wards--........................................... 1.0 cu. ft. per minute per square foot of floor area Dining-rooms.................................. 1.5 cu. ft. per minute per square foot of floor area Toilets........................ ..................... 2.0 cu. ft. per minute per square foot of floor area Kitchens-....... ........... 4.0 cu. ft. per minute per square foot of floor area Air temperature is second in the list for the reason that it has been proved by practically all of the accredited experimenters that over-heating is more detrimental to the quality of ventilation than any other one thing.
Document image
refid# OE7yojVoQ8VB6Nr9Bp6kZY9wj1 page
American Society of Heating and Ventilating Engineers Guide, 1929 Table 5.
Document image
refid# DRvOQgynO5BEVpwbv5xGEZa51 page
American Society of Heating and Ventilating Engineers Guide, 1929 On new jobs it is advisable wherever possible to drain condensation directly to sewer during first week of operation, thereby preventing pass age of grease and dirt to the boiler from the system.
Document image
refid# rpGvD5N1KG2VLJJBQqJzagn8J1 page
American Society of Heating and Ventilating Engineers Guide, 1929 blow air through heaters rather than to draw through by suction and most fan furnaces are designed for this arrangement.
Document image
refid# 6Bon4rvJNwB4DkNXNypvqew291 page
American Society of Heating and Ventilating Engineers Guide, 1929 Page D. & T.
Document image
refid# Eq9gKGojqgvQLeqE4RwY79nJb1 page
American Society of Heating and Ventilating Engineers Guide, 1929 1902 President_____ _________ _ 1st Vice-Presidents _A.
Document image
refid# rzLxNEg2dBg518xzV6jYDja01 page
American Society / Heating and Ventilating Engineers Guide, jgjjM will give an effective temperature of 75.7 deg.
Document image
refid# evvRRMd5YbqYGaxwj8gbo6Gy41 page
T a b l e 1.
Document image
refid# Xpb5VRMG4qk2qqa72w5LLBmJ1 page
Air Conditioning and Heating Piping Tubin* Chicago Metal Hose Corporation Maywood, Illinois District Offices Atlanta Boston Chicago Cleveland Detroit Ft.
Document image
refid# rxo5ygG2N7Z2NZOZ64n1qx91J1 page
-77- dusts of the following size characteristics: 99 per cent smaller than 2. 80 microns 95 n 90 ii ti it nn " . 1. 80 " " 1.40 " 60 it ii ii " 1.00 " 70 n ti ii " C. 85 " 60 ti ti it " 0.72 " 50 n n ii " 0.60 " It will be noted that 80 per cent of the dus~ used in these approval tests is below one micron (l/25,000th of an inch) and 50 per cent is below 0.6 microns.
Document image
refid# 82V4aLgG13xE1k684Gpj6RzXZ1 page
... ixriijt tfrrf ** eix'K&g* *' r.
Document image
refid# ZJw2ZvxYZw1eJ9ejznrQJ5y401 page
> l cc accompanied the materials referred to in c) and the dates these first appeared.
Document image
refid# Y2eR8GXMzNvVpb7nrkq555gy1 page
Exhibit 3 JPATTOfsTAt -v.kunmeNTAL health Montreal, Canada Mortality in the Chrysotile Asbestos Mines and Mills of Quebec ].
Document imageDocument imageDocument imageDocument image
refid# JJnJRJM1mDyLemKnX7zKw7mOe9 pages
Heating Systems specialties Armstrong Machine Works 851 Maple Street, Three Rivers, Mich.
Document image
refid# Nemg4pb563evooN676GGK6mqQ1 page