Document o9j39KJOod4MaOqVerNG5dwLr

M S.a.6 - 0& 7. Centre Analytical Laboratories, Inc. 3048 Research Drive Phone: (814) 231-8032 State College, PA 16801 Fax: (814) 231-1253 or (814) 231-1580 Analytical Report Fluorochemical Characterization of Surface Water Samples Cleveland, Tennessee (W1973) Centre Analytical Laboratory Report No. 023-014A Testing Laboratory Centre Analytical Laboratory, Inc. 3048 Research Drive State College, PA 16801 3M Environmental Laboratory Contact Kent R. Lindstrom Bldg. 2-3E-09 P.O. Box 33331 St. Paul, MN 55133-3331 Phone: (651)778-5352 Requester Kris J. Hansen, Ph.D. 3M Environmental Technology & Safety Services Bldg. 2-3E-09 P.O. Box 33331 St. Paul, MN 55133-3331 PAGE 1 0 F 5 000955 1 Introduction Results are reported for the analysis of a series of surface water samples received by Centre Analytical Laboratories, Inc. (Centre) from the 3M Environmental Laboratory. The samples were collected from Cleveland, Tennessee. The Centre study number assigned to the project is 023014. Specific fiuorochemical characterization by liquid chromatography / tandem mass spectrometry (LC/MS/MS) was requested for all samples. A total of 8 samples were received for analysis. The samples were prepared and analyzed by LC/MS/MS for the following list of fluorochemicals: Table 1: Target Analysis Compound Name Perfluorooctane Sulfonate Perfluorooctane Sulfonvlamide Perfluorooctanoate Acronym PFOS PFOSA POAA The analytical method used here was validated by Centre. The validation protocol and results are on file with Centre. Data presented here is the highest quality data available at this time. 2 Sample Receipt The samples were submitted in individual plastic containers and were not preserved. Eight individual sample containers were received. Samples were received on 05/03/00. The sample collection dates were not supplied. Chain-of-custody information is presented in Attachment A. Sample MC-102H was not analyzed as per client request. (E-mail communication from Kris Hansen on 5/16/00). 3 Holding Times The analytical method used was validated against a maximum holding time of 14 days. The stability of the analytes of interest for longer periods has not been determined. PAGE 2 OF 5 000956 4 Methods - Analytical and Preparatory 4.1 LC/MS/MS 4.1.1 Sample Preparation for LC/MS/MS Analysis Samples were initially treated with 200 uL of 250 mg/L sodium thiosulfate solution to remove residual chlorine. Solid phase extraction (SPE) was used to prepare the samples for LC/MS/MS analysis. A forty-milliliter portion of sample was transferred to a C SPE cartridge. The cartridge was first eluted with 5 mL of 40% methanol in water solution. The eluate was discarded and the SPE column was then eluted with 100% methanol. A 5 ml portion of methanol was collected for analysis by LC/MS/MS. This treatment resulted in an eight-fold concentration of the samples prior to analysis. 4.1.2 Sample Analysts by LC/MS/MS In HPLC, an aliquot of extract is injected and passed through a liquid-phase chromatographic column. Based on the affinity of the analyte for the stationary phase in the column relative to the liquid mobile phase, the analyte is retained for a characteristic amount of time. Following HPLC separation, ES/MS provides a rapid and accurate means for analyzing a wide range of organic compounds, including fluorochemicals. Electrospray is generally operated at relatively mild temperatures; molecules are ionized, fragmented, and detected. Ions characteristic of known fluorochemicals are observed and quantitated against standards. A Hewlett-Packard HP 1100 HPLC system coupled to a Micromass Ultima MS/MS was used to analyze the sample extracts. Analysis was performed using selected reaction monitoring (SRM). Samples were extracted on 5/16/00 and analyzed by MS/MS oh 5/18/00. Sample MC108H was extracted on 5/22/00 and analyzed on 5/23/00. The HPLC and MS/MS methods used for analysis and instrument parameters can be found in attachment D. 5 Analysis 5.1 Calibration A 7-point calibration curve was analyzed at the beginning and end of the analytical sequence for the compounds of interest. The calibration points were prepared at 0, 25, 50, 100, 250, 500, and 1000 ng/L (ppt) The response of the quantitation ion versus the concentration was plotted for each point. Using linear regression with 1/x weighting, the slope, y-intercept and correlation coefficient (r) and coefficient of determination (r2) were determined. A calibration curve is acceptable if r >0.985 (r2 > 0.970). Calibration standards are prepared using the same SPE procedure used for samples. Calibration check standards were analyzed periodically (every three to five sample injections) throughout the analysis sequence. Compliance is obtained if the standard analyte concentrations are within +/-20% of the actual value. For the results reported here, calibration criteria were met. PAGE 3 OF 5 5.2 Blanks Extraction blanks were prepared and analyzed with every extraction batch of samples. The extraction blanks should not have any target analytes present at or above the concentration of the low-level calibration standard. For these samples, the extraction blanks were compliant. Instrument blanks in the form of clean methanol solvent were also analyzed after every highlevel calibration standard, and after known high-level samples. Again, the blanks should not have any target analytes present at or above the low-level calibration standard. For the samples presented here the instrument blanks are compliant. 5.3 Surrogates Surrogate spikes are not a component of the LC/MS/MS analytical method. 5.4 Matrix Spikes Matrix spikes were prepared for every field sample (excluding blanks) at a concentration of 100 ng/L using all compounds of interest. Matrix spike recoveries are given in Attachment C. All laboratory matrix spikes showed recoveries of all compounds between 70-130%. Field spikes were prepared on sample MC-101H at a concentration of 100 ng/L using all compounds of interest. Field spike recoveries are also given in Attachment C. PFOSA showed low recovery in the field spike. All other compounds showed recoveries between 70130%. 5.5 Duplicates All field samples (excluding blanks) were analyzed in duplicate. Results are given along with the sample results in Attachment B. 5.6 Laboratory Control Samples Milliq water was spiked with all compound of interest at 25 and 250 ng/L. All recoveries for all compounds were between 70-130% in each LCS. Recoveries are given with the raw data in Attachment D. 5.7 Sample Related Comments Field blank samples consisted of empty containers. Forty milliliters of type I water filtered through a hypercarb cartridge was added to the empty container and analyzed in the same manner as the other samples. 6 Data Summary Please see Attachment B for a detailed listing of the analytical results. 7 Data/Sample Retention Samples are disposed o f one month after the report is issued unless otherwise specified. All electronic data is archived on retrievable media and hard copy reports are stored in data folders maintained by Centre. PAGE4 OF 5 000958 8 Attachments 8.1 Attachment A- Chain-of-Custody 8.2 Attachment B: Results. 8.3 Attachment C: Matrix Spike Recoveries (Field and Laboratory Spikes) 8.4 . Attachment D: LC/MS/MS Raw Analytical Data 9 Signatures Other Lab Members Contributing to Data Enaksha Wickremesinhe Karen Smith David Beil PAGE5 OF5 000959 ANALYTICAL REPORT iS5SS\ Centre Analytical SgvwiBk. Laboratories. Inc. 3048 Research Drive, State College PA 16801 814-231-8032 FAX 814-231-1253 Analytical Results W1973 Cleveland, Tennesse 3M Sample Identification Sample Description PFOS (ng/L) PFOSA (ng/L) MC-101H MC-103H MC-106H NA MC-107H NA MC-108H Site 1 P IN Surface Water Site 1 P/N Surface Water Duplicate Site 2 P/N Surface Water Site 2 P/N Surface Water Duplicate Site 3 P/N Surface Water Site 3 P/N Surface Water Duplicate Field Blank P/N Empty -- 14.7 J <25 <25 <25 <25 <25 <25 5.6 J <25 <25 <25 <25 <25 < 25 J - Compound Is present, but below the reporting limit of 25 ng/L. The result is an estimated value. Method Detection Limits are approximately 2.5 ng/L for PFOS and PFOSA and 7.5 ng/L for POAA. POAA (ng/L) 16.7 J < 25 < 25 < 25 <25 <25 < 25 Please refer to the reverse side fo r o u r standard term s and conditions. flOOSGO BEST COPY AVAI LAI i l mV HuhWTr /ik 'F v r*rr * t 01009 Mapquwrt.com. In a; 01990 GOT. In a Adsdhiotiwonnaolnsasomupthlinmgaspites Environmental Sampling Sites North of Cleveland, TN 000901 Adsdhiotwionnaolnsanmorpthlinmgaspites Environmental Sampling Sites for Cleveland, TN 000962