Document npr5yeVQmzOMGMq7vz77V2636

342 Heating Systems I BUera, SMI * Cm ud OU 343 COLUMBIA Boiler Company of Pottstown Pottstown, Pa. 17 Makers of steel power and heating boilers COLUMBIA'S H~R/T.* OIL OR GAS FIRED BOILER & STEAM GENERATOR COLUMBIA Boiler Company of Pottstown Pottstown, Pa. Makers of steel power and heating boilers STEEL, TUBELESS, OIL-FIRED, WATER TUBE GAS-FIRED AND COAL-FIRED HEATING UNITS ASME CODE CONSTRUCTED Available for pressures of 15 to 250 psi. A complete, automatic power plant wherever steam is used for processing Columbia h.r.fc. boilers are fully automatic, compact, complete steam generators. Available in sices ranging -from-2 to 100 horsepower.-Designed.for firing .with gas, light or heavy oils. A special Columbia unit makes pos sible the inter-changeable use of gas or oil. Overfiring Permitted: Conservative ratings plus large combustion volume permit overfiring. This frequently eliminates the need for additional boiler capacity, al lows for plant expansion. High Steam Output: Columbia's h.r.t. boilers have an unusually large heating surface to produce more steam at higher efficiencies. More heat is converted into steam since it is proportioned to make maximum use of hot gases of combustion for the production of steam. Horizontal Design for longer life; The complete sub mersion of tubes protects them from water line cor rosion. Dry Steam Assured: Large steam space and greater liberation area virtually eliminate waste producing water carryover. Over-All Efficiency: Factory installed, specially de signed combustion chamber provides rapid heating re fractory surfaces for peak combustion efficiency. In sulation, 7 inches thick in the combustion chamber _proper,_and 4_inches_thiek in the gas passage, keeps heat loss at a minimum. Special refractory brick'heats' up to great intensity to complete the combustion of previously unignited fuel particles. This complete com bustion not only increases efficiency but makes for clean combustion. Soot accumulation on heating sur faces is minimized. Boiler tubes require less cleaning. Safely Assured: Two pass updraft design lowers direct loss and reduces possibility of furnace pressure, pulsation or excessive combustion noises. Accessibility and easy Maintenance: Simplified con struction provides easy front and back access to the single bank of tubes. Entire unit can be gotten to for inspection of boiler and chamber by removing the SPECIFICATIONS AND DATA COLUMBIA HRT BOILERS FOR GAS, LIGHT OIL OR DUAL FUEL HORIZONTAL RETURN TUBULAR TYPE ASME CODE CONSTRUCTED SB! RATED A.G.A. APPROVED (. S 13 8rr- Available with highly efficient, custom engineered gas or oil burners. Columbia steel boilers, gas or oil fired, have self contained large copper instantaneous tank less coils,,supplying. a.continuous flow .of.year ground domestic hot water. ___ Maximum operating efficiencies assured by the bal anced design of the boiler and burner; by the arrange ment of the baffles which force the hot gases to travel four or five times the full length of the boiler. One piece electric welded construction: Columbia offers a heating unit with full electric welded construc tion of heavy copper bearing steel, to assure lower heat ing cost and longer operating life. Quiet operation: Ample combustion space; the insula tion and heavy steel jacket completely eliminate objectional noise. Dual Firing: Columbia oil heating units may be easily converted for efficient gas firing. Oil and gas burners for Columbia Boilers are designed and manufactured by Columbia to insure maximum per formance of boiler-bumer units and to provide undivided responsibility. MODEL NO. L-16 L-18 L-20 L-22 L-24 L-30 Ratings--Oil Fired Input--Gals per Hr..................................... SBI Net Rating Sq Ft Forced Water................................... Sq Ft Gravity Water.................................. Sq Ft Steam................................................. Btu per hr Forced Water.......................... Btu per hr Gravity Water......................... Btu per hr Steam........................................ 1.00 580 510 320 87,000 77,000 77,000 1.20 720 640 400 108,000 96,000 96,000 1.35 990 880 550 149,000 132,000 132,000 1.75 1260 1120 700 189,000 168,000 168,000 2.25 1620 1440 900 243,000 216,000 216,000 3.00 1980 1760 1100 297,000 264,000 264,000 ^Constructed Water^Tube Only " Gas Fired Units A.G.A. and SUR Approved for outputs from 72,000 to 172,000 Btu's per hour. Coal Band Fired Conversion Unite available in sizes L-18, L-22 and L-30 L-32 4.00 2700 2400 1500 405,000 360,000 360,000 L-40 7.00 3500 y 2200 600,000 530,000 530,000 COLUMBIA BASEBOARD RADIATION Suspended Element--no noise 1 Tension Fastening--no rattling! Low Angle Heat--no drafts! Pre-Punched Holes--fast installation!