Document mpZXaLQDNk2jGYwDea5QwVx2d
COMPANY CONFIDENTIAL
RESEARCH AND DuyELOPMENT REPORT
ANNISTON PLANT
OTHER LOCATIONS
GENERAL OFFICE
J. R. Savage - WGK P. E. Heisler - WGK D. C. Armstrong - WGK A. F. Regan - MCL C. R. Coleman - MCL H. L. Hubbard - So. 2nd
H. C. Carder P. G. Benignus R. A. Steenrod G. R. Buchanan H. 0. Hehner
X R. A. Munch C. M. Williams J. Cresce
Job No. Date
370-503 ___ 5-5-67_____ ,________
ANNISTON PLANT
W. B. Papageorge L. C. Fuhrmeister J. MacPherson J, G. Bryant V, R. Haupt W. B. Dunlap
Title:
Quality Report on Japanese Kanechlor 300 and Bayer Clophen A-50
Personnel:
s. 0. Kemp and G. W. Miller
Problem:
Quality Surveillance of Competitive Insulating Fluids in Competition with Monsanto Aroclor
Justification: Protection of Domestic Sales and Increase Potential for Foreign Sales
Summary:
Bayer Clophen A-50 is quite superior to Anniston and WGK Aroclor 1254 in electrical properties. This material as received exhibited a resistivity ' of 150,000 x 10^ and thermal chemical chloride stability of 0.27 ppm.
Japanese Kanechlor 300 is also superior to Anniston and WGK Aroclor 1242. Even though this material had a 9,600 x 10^ resistivity and 0.08 ppm TC it is still considerably better than any routine domestic production in Monsanto operations.
G W^Miller /dp
DSW 200779 STLCOPCB4058843
Research and Development Report No. 1
Job No. 370-503
-2
Background
The last report concerning competitive Aroclor type material was issued during October 1966. In that report (435-5-66) a comparison of Clophen A-30, Pyralene 1499, and Aroclors from the three Monsanto production facilities was presented. Also presented was a comparison of Pyralene 1476 and Anniston Aroclor 1254.
The additional data presented in conjunction with values cited from the above report should serve as a useful data source for summarization of Monsanto's marketing position at the end of 1966.
Discussion
Bayer Clophen A-50
This material was received in a 16 gauge, welded seam galvanized steel drum. Even though the drum was equipped with rolling hoops it was dented in several locations during transit. It is apparently characteristic of Bayer to use drums equipped with side wall bungs.
As in previous sampling of competitive drums this material was sampled by insertion of a clean glass tube and displaced into clean bottles with dry nitrogen. One sample of the material was obtained at room temperature; however, due to the high viscosity the drum was necessarily transferred to the Aroclor Department hot house to aid in sampling. Analysis of the sample drawn prior to warming the drum gave a resistivity of 190,000 x 10^. This value could not be achieved after warming. Several replicate tests on the samples collected from the warm drum showed a maximum of 150,000 x 10^. All stability tests were performed in duplicate or triplicate.
The dielectric fluid compares favorably with Monsanto Aroclor 1254 specifications in all areas except that gravity and index are too low and the dielectric constant is above our spec limit.
Isomer distribution and a full analysis report are included in the attached tables.
Japanese Kanechlor 300
This material was received in a 35 gallon welded seam galvanized steel drum. This material was sampled indoors without any heat being applied.
The material was submitted to at least two analyses on all electrical and stability properties.
There are no test properties on this material which are not within the specification limits of Aroclor 1242.
Isomer analysis and a full analysis report are included in the attached tables.
DSW 200780
STLCOPCB4058844
Research and Development Report No. 1
Job No. 370-503
-3
Future
Two five pint samples of these materials are being forwarded to WGK for analysis. It would be appropriate to report WGK results on the aforementioned materials in this report; however, in the interest of having this data available at the May 9 quality conference the report contains only Anniston results. If serious dis crepancies develop in the data comparison with WGK, a follow-up report will be issued.
/dp Att. 4
G. W. Miller
oS\N 20781 STLCOPCB4058845
Research and Development Report No. 1 Job No. '370-503
-4 -
Table I
Comparison of Competitive Materials With Monsanto Aroclor 1242
Property
Bayer Clophen
A-30
Prodelec Pyralene
1499
Anniston AH-248
MCL Z-16
WGK B #450
Color, APHA
<5
Acid No.
0.001
Ref. Ind. @ 25C 1.6237
Sp. Gr. @ 25C
1.378
Vise. @ 100F, SUS 79.8
<5 0.002 1.6245 1.387 85.7
15 0.001 1.6248 1.386 90.2
15 0.001 1.6249 1.388 86.9
15 -- -- -- --
Moisture, ppm
63
35
30 52 28
Free Chlorides, ppm 0.01
0.01
0.01
0.01
0.01
HST, ppm Cl
0.11
0.16
0.14
0.32
0.50
Mon. Stab., ppm Cl 0.06
0.06
0.11
0.12
0.16
TC Stab., ppm Cl 0.07
0.12
0.28
0.48
0.48
West. Stab., ppm Cl 0.40
Resist, x 10^,
OHM/CM, 100C P.F. @ 100C
60 cycles 1 KC
15,200
0.22 0.06
0.48 1,270
4.6 0.33
0.51 1,980
2.0 0.17
1.56 1,900
0.93 1,030
3.4 0.25
4.8 0.28
D.K. @ 100C, cycles
Distillation 10%
90%
4.90
327 348
4.87
330 352
4.83
328 352
4.80
327 348
4.90
... --
Type drum
Steel, galv. Steel, welded
dipped.
seams. Type of
16 ga.
lining to be
determined
One coat phenolic lining
Two coats Bottle phenolic lining
Appearance of drum Good, no dents
Head bent, rim seam split, lining flaking
Good as produced
Good, no major dents
Bottle
Kanechlor 300
Japan 10 0.001 1.6248 1.390
24 o,oo9
0.11 0.06 0.08
0.36 9,600
0.55 0.13 4.82 331 352 Steel welded seams, galvanized Good
DSW 200782
STLCOPCB4058846
Research and Development Report No. 1 Job No. 370-503
-5-
Table II
Comparison of Competitive Material With Aroclor 1254
Test Date
10-15-66
10-5-66 .
4-30-67
Property
Prodelec Pyralene
1476
Aroclor 1254 AH-68
Bayer Clophen
A-50
Color, APHA
10 20 7
Acid No.
0.002
0.002
0.001
Ref. Ind. @ 25C
1.6380
1.6382
1.6365
Sp. Gr. @ 25C
1.503
1.504
1.490
Vise. @ 210F, SUS
46.2
45.9
Moisture, ppm
30 20 30
Free Chlorides, ppm
0.02
0.02
0.009
Hydrolysis Stab., ppm Cl
0.14
0.14
0.07
Thermal Chem. Stab., ppm Cl
0.32
0.30
0.28
Westinghouse Stab., ppm Cl Resist, x 109, OHM/CM, 100C
1.00 3,180
1.13 5,880
0.62 150,000
Power Factor @ 100C, 60 cycles 1 KC
1.5 0.14
0.60 0.10
0.288 0.09
Dielectric Constant, @ 100C, 60 cycles
4.23
4.25
4.37
Distillation - 10% 50% 90%
368 370 365 376 376 373 387 388 387
Monsanto Stability, ppm Cl
0.18
0.14
0.10
Type drum
Steel, welded seams, 16 ga. Type of lining to be determined
One coa t phenolic lining
Steel weld< seams. Galvanized rolling hoops
Appearance of drum
Good, no dents
Good as produced Good
DSW 200783
STLCOPCB4058847
Research and Development Report No. 1 Job No. 370-503
6-
Table III GLC Analyses of Competitive Aroclor 1242
Peak
Japan Kanechlor Anniston 300 WGK
England Bayer Prodelec Identification
1
0.03
0.01
0.11 0.05
Trace 0.009
Biphenyl
2
0.79
0.01
0.13 0.18
0.003 0.01
2 Chloro
3-4-5
0.25
Trace
0.04 0.07
0.03 Trace
3 Chloro-4 Chloro
6-7
4.39
3.02
3.30 3.69
4.91 3.44
2,2'; 2,6
8-9-10 11
11.79 1.15
8.57 1.15
9.98 0.74
10.19 1.26
12.36 8.91 1.19 1.06
2,5; 2,4; 2,3'; 2,4'; 2,3 3,5
12-13-14-15 16-17-18-19-20
21.64 27.56
24.03 32.27
26.50 25.04 32.72 32.78
26.33 28.23 31,32 34.26
3,4; 3,4'; 2,5,2' 4; 4; 2,3,2' 2,5,4'; 3,4,2'; 2,3,4
21-22-23-24
7.50
7.08
7.05 6.59
5.79 6.79
25-26-27
10.04
10.22
9.69 8.84
8.58 9.51
3,4,4'
28-29-30-31
8.07
7.24
6.26 6.23
5.29 6.66
32-33-34
3.50
3.31
2.51 2.64
2.32 2.60
35-36-37-38-39-40 1.57
1.19
0.69 0.87
0.85 0.77
41-42
0.69
0.62
0.23 0.36
0.46 0.40
43-44-45-46
0.41
0.39
0.11 0.25
0.31 0.22
47-48-49
0.09
0.21
0.02 0.08
0.16 0.09
50-51
0.04
0.04
0.02 0.11
0.03 0.02
52
0.01
0.04
Trace 0.03
0.01 0.005
53-54-55-56
0.07
0.13
0.02 0.22
0.03 0.09
57
NDA
0.08
NDA 0.02
NDA NDA
58-59-60 61-62-63
0.06 Trace
0.10 0.08
Trace 0.26 NDA 0.17
0.01 0.01 NDA Trace
DSW 200784
64
NDA
Trace
NDA 0.10
NDA NDA
STLCOPCB4058848
Research and Development Report No. 1 Job No. 370-503
-7-
Peak 1 2 3-4-5 6-7 8-9-10 11 12-13-14-15 16-17-18-19-20 21-22-23-24 25-26-27 28-29-30-31 32-33-34 35-36-37-38-39-40 41-42 43-44-45-46 47-48-49 50-51-52 53-54-55-56 57 58-59-60 61-62-63 64
Table IV
GLC Analyses of Competitive Aroclor 1254
Anniston 1254
WGK 1254
Bayer Clophen
A-50
0.015
0.02
Trace
0.01
0.36
Trace
Trace
0.16
0.01
0.07
0.04
0.23
0.46
0.19
0.75
0.05
0.01
0.03
1.09
0.48
0.76
1.59
0.81
1.11
8.34
7.80
8.03
4.01
3.59
4.61
13.29
13.09
14.27
16.11
16.24
16.66
17.77
18.23
19.35
13.14
14.12
12.85
11.05
11.65
10.23
8.32
8.77
7.10
1.98
2.02
1.68
1.56
1.56
1.37
0.64
0.66
0.39
0.50
0.62
0.50
NDA
Trace
Trace
NDA NDA 0.02
Prodelec Pyralene
1476 Trace Trace 0.12 Trace 0.30 0.04 0.90 1.35 8.08 3.32 12.35 15.80 18.10 14.26 11.93 8.70 2.10 1.36 0.80 0.46 Trace NDA
DSW 200785
STLCOPCB4058849